101 research outputs found

    Impact of glazing type and orientation on the optimum dimension of windows for office room in hot climate

    Get PDF
    This study aims to show the impact of orientation and glazing type on optimum window size in hot climate using genetic algorithms. In winter the optimization of window size is obtained thanks to thermal gains from solar radiation, taking into account this free heat gains from the sun reduces heating demand of the building. In summer the optimization of window size is complex, in this case, the window is considered as a heat gains element. For a hot climate, the sun can be used as a passive strategy to reduce energy consumption. An optimal window size allows avoiding problems of glare and overheating. ASHRAE proposed a Window to Wall Ratio (WWR) which is considered as the optimal window size that ensures minimum annual thermal loads, this coefficient neglect different parameters such as (Glazing type, the orientation, daytime). A typical office room located in Ghardaia (South of Algeria) is selected as a case study. The results show that daylight is a key factor in limiting the window size in hot climate. The WWR cannot be considered as optimal for the whole year; this study shows that the optimal window size varies with daytime

    Ventilation adaptée des combles en vue de l'amélioration de l'efficacité énergétique des constructions

    Get PDF
    Ce travail a pour but d'analyser l'influence de la présence d'un comble sur la consommation énergétique d'une construction. Des essais ont donc été menés sur une construction avec comble implantée à Bou Ismail au sein de l'Unité de Développement des Equipements Solaires (UDES). L’étude du comportement thermique de cette construction a été réalisée pendant les périodes hivernale et estivale. Des températures d'air de différentes zones thermiques de la construction ont été relevées et ont été comparées aux températures d'air calculées à partir d'un modèle numérique réalisé en utilisant le logiciel TRNSYS. Un modèle numérique calibré a pu ainsi être obtenu et a été utilisé pour réaliser différentes simulations numériques en faisant varier le taux de ventilation du comble. Les résultats des simulations ont permis de montrer que la diminution des besoins de climatisation est proportionnelle à l’augmentation du taux de ventilation du comble en été, et que la diminution des besoins de chauffage est proportionnelle à la diminution du taux de ventilation du comble en hiver

    Effects of a balanced translocation between chromosomes 1 and 11 disrupting the DISC1 locus on white matter integrity

    Get PDF
    Objective Individuals carrying rare, but biologically informative genetic variants provide a unique opportunity to model major mental illness and inform understanding of disease mechanisms. The rarity of such variations means that their study involves small group numbers, however they are amongst the strongest known genetic risk factors for major mental illness and are likely to have large neural effects. DISC1 (Disrupted in Schizophrenia 1) is a gene containing one such risk variant, identified in a single Scottish family through its disruption by a balanced translocation of chromosomes 1 and 11; t(1;11) (q42.1;q14.3). Method Within the original pedigree, we examined the effects of the t(1;11) translocation on white matter integrity, measured by fractional anisotropy (FA). This included family members with (n = 7) and without (n = 13) the translocation, along with a clinical control sample of patients with psychosis (n = 34), and a group of healthy controls (n = 33). Results We report decreased white matter integrity in five clusters in the genu of the corpus callosum, the right inferior fronto-occipital fasciculus, acoustic radiation and fornix. Analysis of the mixed psychosis group also demonstrated decreased white matter integrity in the above regions. FA values within the corpus callosum correlated significantly with positive psychotic symptom severity. Conclusions We demonstrate that the t(1;11) translocation is associated with reduced white matter integrity in frontal commissural and association fibre tracts. These findings overlap with those shown in affected patients with psychosis and in DISC1 animal models and highlight the value of rare but biologically informative mutations in modeling psychosis

    Conception d'un environnement de simulation intelligent. Application à la thermique du bâtiment

    Get PDF
    Ce travail de thèse s'insère dans le cadre plus général du développement par le Centre Scientifique et Technique du Bâtiment d'un Environnement de Simulation Intelligent destiné à faciliter l'accès aux logiciels de calculs scientifiques dans le secteur Bâtiment. Il s'agit d'un programme pluriannuel de recherches dont les objectifs sont de mettre à la disposition des professionnels de nouveaux outils d'aide à la conception et d'aide à l'analyse des systèmes "Bâtiments", basés sur la simulation numérique suivant divers points de vue (thermique, acoustique, structure, etc.). Le présent travail de recherche s'articule donc avec d'autres travaux menés en parallèle sur le même thème. Dans ce contexte, les objectifs fixés sont de trois ordres : - contribuer à la définition des spécifications de l'environnement de simulation générique notamment en analysant le processus de modélisation/simulation et en proposant des solutions pour la réalisation du dialogue Homme/machine ; - réaliser une application concrète que l'on peut considérer comme une phase expérimentale de mise en oeuvre des concepts développés ; cette application est réalisée autour du logiciel de calculs thermiques TRNSYS ; - définir, pour de tels environnements, les possibilités d'utilisation des systèmes à bases de connaissances (buts et moyens, évaluation de la pertinence des solutions). Après une première partie consacrée aux réflexions conceptuelles générales menées sur la base d'une analyse bibliographique et aux analyses nécessaires à la réalisation de l'application, la seconde partie du travail est consacrée à l'application proprement dite ; un environnement dénommé IISIBât (Interface Intelligente pour la Simulation dans le Bâtiment) est développé suivant les concepts précédemment définis ; dans une première phase, la stratégie de développement d'une telle interface est précisée ; le processus de conception est fondé sur la mise en oeuvre séquentielle de quatre modèles : les modèles cognitif, conceptuel, structurel et perceptif. Le modèle cognitif met en évidence les tâches que l'utilisateur est amené à réaliser dans le cadre d'un outil de simulation ; le processus de modélisation/simulation est décortiqué en ses diverses étapes ; ce travail permet de définir une interface homme/machine possible (et en particulier les outils nécessaires) spécialisée pour ce type de process. Le modèle conceptuel identifie les objets génériques sur lesquels se fonde l'interface, les fonctions rattachées à ces objets, et la représentation graphique de ces objets. Le modèle structurel s'intéresse à l'implémentation proprement dite. Le modèle perceptif représente la façon dont l'utilisateur perçoit le système final ; ce modèle conduit à une analyse critique des choix effectués et à la proposition d'améliorations. Au final, l'application réalisée (IISIBât- TRNSYS) permet de juger de la pertinence des concepts développés tant du point de vue du fond que des méthodes utilisées ; ainsi, l'intérêt de l'application développée pour des utilisateurs "développeurs de modèles" ou "créateurs de projets" a pu être démontré ; par ailleurs, il s'est avéré que cette application ne possédait pas toutes les fonctionnalités nécessaires à une utilisation efficace par des utilisateurs terminaux (analystes de systèmes) ; pour combler ces manques, il faut rajouter à l'interface des mécanismes de raisonnement. La dernière partie de ce travail s'intéresse à l'introduction au sein de l'application interactive de mécanismes de raisonnement faisant appel à des bases de connaissances
    corecore