429 research outputs found

    Integrated optical motion detection

    Get PDF
    Two systems for detecting the motion of a scene are described. For both, an image is projected directly onto an integrated circuit that contains photosensors and computing circuitry to extract the motion. The first system, which has been reported earlier, correlates the analog image with a digitized version of the image stored from the previous cycle. The chip reports the motion that corresponds to the maximum analog correlation value. This system represents an advance from previous designs but exhibits some shortcomings. A second completely analog design surpasses the first. The mathematical foundation is derived and the CMOS circuits used in the implementation are given. Test results and characterization of the working chips are reported. The new motion detector is not clocked and exhibits collective behavior. The extensive use of local information avoids the correspondence problem. The system can be thought of as a Hopfield neural net with one important extension--input-driven synapses. The motion detector also meshes nicely with the existing computational vision work. Extensions to handle more complex motions are proposed. The suitability of the motion-extraction algorithm as a biological vision model is explored

    Ordinary Generating Functions of Context-Free Grammars

    Get PDF
    A context-free grammar is a set of mathematical rules that classifies strings (sequences of symbols) as either valid or invalid . Given a context-free grammar, the set of all valid strings is known as a context-free language. The counting sequence of a language is defined as the sequence of numbers stating how many strings of each length are elements of the language. Finally, the ordinary generating function of a sequence is the power series whose coefficients are the elements of the sequence. This paper investigates the properties of ordinary generating functions of counting sequences of context-free languages. We also discuss the Chomsky–Schützenberger Theorem, an important theorem about these generating functions

    The 1960s and their Aftermath: From Peaceful Protest to Guerilla Warfare

    Get PDF
    In many esential respects the 1960s differed markedly from previous ages of social protest and agitation. It was a period of economic prosperity, not decline and depression. The agents of rebellion were youthful, finding their own path and ignoring the past. The rebellion was world wide, but from out of its incubation in the United States the manifestations were first, strongest, and most lasting. Here, in a selection of material from the University of Michigan's Labadie Collection, are the paper witnesses to that era.http://deepblue.lib.umich.edu/bitstream/2027.42/120284/1/the_1960s_93.pd

    Design, analysis, testing, and evaluation of a prosthetic venous valve

    Get PDF
    Chronic Venous Insufficiency (CVI) is characterized by chronic venous hypertension from blood pooling in the lower limbs. The resulting symptoms include leg pain, varicose veins, fatigue, venous edema, skin pigmentation, inflammation, induration, and ulceration. Reflux from incompetent venous valves is a factor in up to 94% of individuals with CVI. Current treatments of CVI include compression stockings, drug therapy, vein disabling, venous stenting, and surgical correction with varying rates of success. However, a minimally invasive correction of deep venous reflux does not currently exist. A transcatheter prosthetic venous valve has the potential to be an effective, minimally invasive treatment for deep venous reflux which could treat up to 1.4 million individuals in the United States suffering from venous ulceration and make more than 1.7 billion dollars each year. Previously developed prosthetic venous valves have had problems with competency, patency, thrombogenicity, biocompatibility, and incorrect sizing. To meet the clinical need a prosthetic valve needs to be developed which succeeds where previous valves have failed. This thesis describes the design, analysis, pre-clinical testing, and evaluation of a novel prosthetic venous valve. Design specifications for an effective prosthetic venous valve were created. Verification tests were developed and performed which demonstrated that the valve met every design specification. Finite element and computational fluid dynamics simulations were performed to analyze the valve and calculated a maximum shear rate of 2300 s-1 in the valve during the high forward flow after a Valsalva maneuver. The valve is made of a biocompatible material that has low thrombogenicity, Poly(vinyl-alcohol) cryogel. On the average, the valve allows less than 0.5 mL/min of reflux at low and high retrograde pressures even after 500,000 cycles, indicating that it will reduce the reflux of individuals with venous reflux by more than 99.4%. The valve closes in less than 0.07 seconds and allows the distal pressure to rise to an average of 7% of the equilibrium pressure 30 seconds after a simulated ankle flexion. The valve increases the outflow resistance an average of 2.3 mmHg*min/L which is much less than obstruction levels,≥ 5 mmHg*min/L. The valve can fit in a 16 French catheter and is capable of percutaneous delivery. The base of the valve is 1.5 times the diameter of the vein in which it is to be implanted to help correct orientation upon deployment. Fluid behind the valve’s leaflets is ejected with a forward flow rate of 400 mL/min, suggesting that thrombus formation will not occur at this location. A stented valve remained patent in a porcine blood flow loop for 3 hours. The valve remains competent without buckling in a constricted vein at rest. The valve can expand to fit a vein with a maximum diameter 1.4 times the valve's initial diameter with low risk of tearing or leaflet prolapse. An IACUC protocol for a 12 week study to test the valve in sheep was prepared and approved. A study to evaluate the valve in humans is proposed with endpoints that can be tested for statistical significance and compared with other treatments for CVI. A set of valves which will correct reflux in the majority of common femoral, femoral, and popliteal deep veins is proposed and a sizing guide for surgeons is provided. The minimum distance between prosthetic valves placed in the same vein segment is 13 cm. A comparison of this valve with previously developed prosthetic venous valves and recommendations for work to be performed in the future are given. The valve proposed in this work is the only valve to meet all design specification for an effective prosthetic venous valve, and therefore shows great potential to be a minimally invasive treatment for deep venous reflux.M.S

    A perpetual switching system in pulmonary capillaries

    Get PDF
    Of the 300 billion capillaries in the human lung, a small fraction meet normal oxygen requirements at rest, with the remainder forming a large reserve. The maximum oxygen demands of the acute stress response require that the reserve capillaries are rapidly recruited. To remain primed for emergencies, the normal cardiac output must be parceled throughout the capillary bed to maintain low opening pressures. The flow-distributing system requires complex switching. Because the pulmonary microcirculation contains contractile machinery, one hypothesis posits an active switching system. The opposing hypothesis is based on passive switching that requires no regulation. Both hypotheses were tested ex vivo in canine lung lobes. The lobes were perfused first with autologous blood, and capillary switching patterns were recorded by videomicroscopy. Next, the vasculature of the lobes was saline flushed, fixed by glutaraldehyde perfusion, flushed again, and then reperfused with the original, unfixed blood. Flow patterns through the same capillaries were recorded again. The 16-min-long videos were divided into 4-s increments. Each capillary segment was recorded as being perfused if at least one red blood cell crossed the entire segment. Otherwise it was recorded as unperfused. These binary measurements were made manually for each segment during every 4 s throughout the 16-min recordings of the fresh and fixed capillaries (>60,000 measurements). Unexpectedly, the switching patterns did not change after fixation. We conclude that the pulmonary capillaries can remain primed for emergencies without requiring regulation: no detectors, no feedback loops, and no effectors-a rare system in biology. NEW & NOTEWORTHY The fluctuating flow patterns of red blood cells within the pulmonary capillary networks have been assumed to be actively controlled within the pulmonary microcirculation. Here we show that the capillary flow switching patterns in the same network are the same whether the lungs are fresh or fixed. This unexpected observation can be successfully explained by a new model of pulmonary capillary flow based on chaos theory and fractal mathematics

    Shock margin testing of a one-axis MEMS accelerometer.

    Get PDF
    Shock testing was performed on a selected commercial-off-the-shelf - MicroElectroMechanical System (COTS-MEMS) accelerometer to determine the margin between the published absolute maximum rating for shock and the 'measured' level where failures are observed. The purpose of this testing is to provide baseline data for isolating failure mechanisms under shock and environmental loading in a representative device used or under consideration for use within systems and assemblies of the DOD/DOE weapons complex. The specific device chosen for this study was the AD22280 model of the ADXL78 MEMS Accelerometer manufactured by Analog Devices Inc. This study focuses only on the shock loading response of the device and provides the necessary data for adding influence of environmental exposure to the reliability of this class of devices. The published absolute maximum rating for acceleration in any axis was 4000 G for this device powered or unpowered. Results from this study showed first failures at 8000 G indicating a margin of error of two. Higher shock level testing indicated that an in-plane, but off-axis acceleration was more damaging than one in the sense direction
    • …
    corecore