77 research outputs found

    Coronary myocardial bridge: an innocent bystander?

    Get PDF
    Myocardial bridge (MB) or tunneled coronary artery is an inborn abnormality, which implicates a systolic vessel compression with a persistent mid-late diastolic diameter reduction. Myocardial bridges are often observed during coronary angiography with an incidence of 0.5%-5.5%. The most involved coronary artery is the left anterior descending artery followed by the diagonal branches, the right coronary artery, and the left circumflex. The overall long-term prognosis is generally benign. However, several risk or precipitating factors (e.g., high heart rate, left ventricular hypertrophy, decreased peripheral vascular resistance) may trigger symptoms (most frequently angina). Herein, we describe two cases of symptomatic myocardial bridge, where medical treatment (i.e., inotropic negative drug) and coronary stenting were successfully utilized to treat this pathology. We also focus on the clinical presentation, and the diagnostic and therapeutic modalities to correctly manage this frequently observed congenital coronary abnormality, underlining the fact that in cases of typical angina symptoms without any significant coronary artery disease, MB should be considered as a possible differential diagnosi

    Intracoronary Heparin Delivery in Humans

    Get PDF
    Background Inefficacy of systemic drug administration for restenosis prevention may partially relate to insufficient local drug concentration. This study aimed to evaluate the acute feasibility and long-term outcome of using an infusion-perfusion coil balloon, Dispatch. Methods and Results In 22 patients after balloon angioplasty, the coil balloon was studied for (1) feasibility of local heparin delivery, (2) symptoms and signs of ischemia during prolonged deployment compared with angioplasty balloon occlusion, (3) coronary pressure and flow distal to the inflated device, and (4) long-term clinical and angiographic results. During prolonged intracoronary deployment of the coil balloon (29±8 minutes), 5 of 22 patients developed mild chest pain versus 20 of 22 during angioplasty (275±283 seconds). Neither hemodynamic nor vectorcardiographic signs of ischemia were detected, in contrast to angioplasty balloon occlusion. Baseline flow across the coil balloon was 44±31 mL/min, increasing by a factor of 1.8±0.7 during pharmacologically induced hyperemia. A mean volume of 14.2±6.1 mL containing 1416±608 IU of heparin was infused locally at a pressure of 122±54 mm Hg. At 7±1-month follow-up, 1 asymptomatic patient had died, and of the remaining 21, 17 (81%) were asymptomatic. Angiographic follow-up was obtained in 15 of 21 patients (71%), including all 4 symptomatic patients. Mean minimal luminal diameter after the procedure was 2.16±0.49 mm and at follow-up, 1.89±0.45 mm, which corresponds to a restenosis rate (diameter stenosis 50%) of 7% (1/15). Conclusions Intracoronary use of the coil balloon after balloon angioplasty proved to be feasible and subjectively as well as objectively well tolerated during prolonged deployment by virtue of its perfusion properties. High volumes of heparin solution can be infused locally at very low pressure. No unfavorable clinical or angiographic long-term effects were observed

    Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type

    Get PDF
    Aim To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Methods and results Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). Conclusion A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957

    Effect of the renin response during renin inhibition : oral RO 42-5892 in normal man

    No full text

    A Cause for Concern

    No full text
    corecore