221 research outputs found

    Gastrojejunocolic fistula after gastrojejunostomy: a case series

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Gastrojejunocolic (GJC) fistulae represent a significant post-surgical cause of morbidity and mortality. GJC fistulae represent rare post-surgical complications, and most are associated with gastric surgery. In the past, this complication has been under-recognized because a fistula may form years after surgery.</p> <p>Case presentation</p> <p>We describe two cases of gastrojejunocolic fistula in men aged 67 and 60 who both initially presented with watery diarrhea and weight loss. Upper GI studies with small bowel follow-through or barium contrast enema studies allowed a conclusive diagnosis to be made. Both patients underwent one-stage en bloc resection, and their postoperative course was uneventful.</p> <p>Conclusion</p> <p>With surgery, this condition is entirely correctable. Pre-operative nutritional status should be evaluated in patients undergoing corrective surgery, and total parenteral nutrition plays a major role in the provision of bowel rest to allow recovery in malnourished patients.</p

    Comparative evaluation of left ventricular mass regression after aortic valve replacement: a prospective randomized analysis

    Get PDF
    Background: We assessed the hemodynamic performance of various prostheses and the clinical outcomes after aortic valve replacement, in different age groups. Methods: One-hundred-and-twenty patients with isolated aortic valve stenosis were included in this prospective randomized randomised trial and allocated in three age-groups to receive either pulmonary autograft (PA, n = 20) or mechanical prosthesis (MP, Edwards Mira n = 20) in group 1 (age 75). Clinical outcomes and hemodynamic performance were evaluated at discharge, six months and one year. Results: In group 1, patients with PA had significantly lower mean gradients than the MP (2.6 vs. 10.9 mmHg, p = 0.0005) with comparable left ventricular mass regression (LVMR). Morbidity included 1 stroke in the PA population and 1 gastrointestinal bleeding in the MP subgroup. In group 2, mean gradients did not differ significantly between both populations (7.0 vs. 8.9 mmHg, p = 0.81). The rate of LVMR and EF were comparable at 12 months; each group with one mortality. Morbidity included 1 stroke and 1 gastrointestinal bleeding in the stentless and 3 bleeding complications in the MP group. In group 3, mean gradients did not differ significantly (7.8 vs 6.5 mmHg, p = 0.06). Postoperative EF and LVMR were comparable. There were 3 deaths in the stented group and no mortality in the stentless group. Morbidity included 1 endocarditis and 1 stroke in the stentless compared to 1 endocarditis, 1 stroke and one pulmonary embolism in the stented group. Conclusions: Clinical outcomes justify valve replacement with either valve substitute in the respective age groups. The PA hemodynamically outperformed the MPs. Stentless valves however, did not demonstrate significantly superior hemodynamics or outcomes in comparison to stented bioprosthesis or MPs

    Evaluation of preoperative intra-aortic balloon pump in coronary patients with severe left ventricular dysfunction undergoing OPCAB surgery: early and mid-term outcomes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of the present study was to evaluate the safety and the cost-effectiveness of using preoperative IABP as support compared with postoperative IABP treatment in coronary patients with severe left ventricular dysfunction (SLVD) who is undergoing off-pump coronary artery bypass surgery (OPCAB), including early outcomes, hospital mortality and morbidity, and mid-term follow-up outcomes.</p> <p>Methods</p> <p>Between March 2000 and December 2008, we prospectively and randomly studied the insertion of preoperative IABP in 115 (7.4%) and postoperative IABP in 106 (6.8%) of the 1560 consecutive patients. Group A is preoperative IABP therapy. Group B is postoperative IABP therapy.</p> <p>Results</p> <p>There was no significant difference in the number of grafts used between the two groups. Completeness of revascularization did not differ between the two groups. The statistically significant difference was hospital mortality (2.6% in group A vs. 3.8% in group B) (<it>p </it>< 0.05). And there was significant reduction in postoperative low cardiac output, malignant arrhythmia, acute renal failure and length of stay in ICU in group A, compared with group B (<it>p </it>< 0.05). In the two groups, six-, 12-, 24- and 48-month survival rates were similar. In the study the degree of improvement in angina and quality of life did not differ significantly between the two groups.</p> <p>Conclusion</p> <p>The use of preoperative IABP in SLVD patients undergoing OPCAB is of safety and effectiveness. The combined use of preoperative IABP and OPCAB allows complete revascularization in SLVD patients with an important reduction in operative mortality and excellent mid-term results.</p

    Ross operation in children and young adults: the Alder Hey case series

    Get PDF
    BACKGROUND: The ideal prosthesis for aortic valve replacement in children and young adults has not been found yet. In recent years there has been a renewed interest in the replacement of aortic valve with the pulmonary autograft owing to its advantages of lack of anticoagulation, potential for growth and excellent haemodynamic performance. The purpose of this study was to review our institutional experience at Alder Hey hospital with the Ross procedure in children and young adults. METHODS: From November 1996 to September 2003, 38 patients (mean age, 13.1 ± 5.7 years) underwent the Ross procedure for various aortic valve diseases using the root replacement technique. Clinical and echocardiographic follow-up was performed early (within 30 days), 3 to 6 months, and yearly after surgery. Medical records of all patients were reviewed retrospectively. RESULTS: There was 1 perioperative death. The patients were followed-up for a median interval of 36 months and up to 7 years. One patient died 3 years after surgery secondary to ventricular arrhythmia with overall mortality of 5.3%. Actuarial survival at 7 years was 94 ± 2.5% and there was 100% freedom from reoperation for autograft valve dysfunction or any other cause. Balloon dilatation was required in 2 patients for pulmonary homograft stenosis. The haemodynamics at the latest follow-up were also similar to those at the time of discharge after surgery. There was no progression in the degree of aortic regurgitation for 11 patients with trivial and 3 with mild regurgitation. CONCLUSION: Our experience demonstrates that Ross operation is an attractive option for aortic valve replacement in children and young adults. Not only can the operation be accomplished with a low operative risk but the valve function stays normal over a long period of time with minimal alteration in lifestyle and no need for repeated operations to replace the valve as a result of somatic growth of the children

    Resection of thoracic malignancies infiltrating cardiac structures with use of cardiopulmonary bypass

    Get PDF
    Background: Only few reports exist on malignant thoracic neoplasms that require cardiopulmonary bypass during resection. We aimed to investigate the early and late clinical outcome of these patients. Methods: Patients with thoracic malignancies that underwent surgery between 2002 and 2014 were analyzed. All patients had cardiopulomonary bypass support during resection. Clinical and perioperative data was retrospectively reviewed for outcome and overall survival. Results: Fifteen patients (12 female, mean age of 55 ± 15 years, range 24 to 80 years) were identified. Eleven (8 female) were diagnosed with primary thoracic malignomas and four with metastases. Three patients died early postoperatively. Patients diagnosed with sarcoma had a significantly worse outcome than non-sarcoma patients (83.3 ± 15.2 % after 1 year, 31.3 ± 24.5 % after 5 years vs. 83.3 ± 15.2 % after 1 year, 0 ± 0 % after 5 years, p = 0.005). Conclusions: Malignancies with extension into cardiac structures or infiltration of great vessels can be resected with cardiopulmonary bypass support and tolerable risk. Carefully selected patients can undergo advanced operative procedures with an acceptable 1-year-survival, but only few patients achieved good long-term outcome

    Clinical experience with the Bicarbon heart valve prosthesis

    Get PDF
    BACGROUND: We have previously reported mid-term results of a study, which ended in January 2000, on the Bicarbon valve. The study concluded that the valve showed excellent clinical results, associated with a low incidence of valve-related complications. In the present study, the same patients were prospectively followed for an additional 5 years. METHODS: Forty-four patients had aortic valve replacement (AVR), 48 had mitral valve replacement (MVR), and 13 had both aortic and mitral valve replacement (DVR). The mean age of the 105 patients was 61.2 ± 11.3 years. The mean follow-up was 6.1 ± 1.9 years with a cumulative follow-up of 616 patient-years. RESULTS: There were 5 early deaths (4.7%: 4 in the AVR group and 1 in the MVR group) and 21 late deaths (3.4%/patient-year: 5 valve related deaths and 16 valve unrelated deaths). Survival at 8 years was 75.2 ± 7.0% in the AVR group, 76.6 ± 6.2% in the MVR group, and 55.4 ± 16.1% in the DVR group. The linearized incidence of thrombo-embolic complications, hemorrhagic complications, and paravalvular leaks in all patients was 0.65 ± 1.48%, 0.81 ± 1.69%, and 0.16 ± 0.54%/patient-year respectively. No other complications were observed. CONCLUSION: The Bicarbon prosthetic heart valve has shown excellent long-term clinical results, associated with a low incidence of valve-related complications

    PAI-1 and t-PA/PAI-1 complex potential markers of fibrinolytic bleeding after cardiac surgery employing cardiopulmonary bypass

    Get PDF
    Background: Enhanced bleeding remains a serious problem after cardiac surgery, and fibrinolysis is often involved. We speculate that lower plasma concentrations of plasminogen activator inhibitor - 1 (PAI-1) preoperatively and tissue plasminogen activator/PAI-1 (t-PA/PAI-1) complex postoperatively might predispose for enhanced fibrinolysis and increased postoperative bleeding.Methods: Totally 88 adult patients (mean age 66 ± 10 years) scheduled for cardiac surgery, were enrolled into a prospective study. Blood samples were collected pre-operatively, on admission to the recovery and at 6 and 24 hours postoperatively. Patients with a surgical bleeding that was diagnosed during reoperation were discarded from the study. The patients were allocated to two groups depending on the 24-hour postoperative chest tube drainage (CTD): Group I > 500ml, Group II ≤ 500ml. Associations between CTD, PAI-1, t-PA/PAI-1 complex and D-dimer were analyzed with SPSS.Results: Nine patients were excluded because of surgical bleeding. Of the 79 remaining patients, 38 were allocated to Group I and 41 to Group II. The CTD volumes correlated with the preoperative plasma levels of PAI-1 (r = - 0.3, P = 0.009). Plasma concentrations of preoperative PAI-1 and postoperative t-PA/PAI-1 complex differed significantly between the groups (P < 0.001 and P = 0.012, respectively). Group I displayed significantly lower plasma concentrations of fibrinogen and higher levels of D-dimer from immediately after the operation and throughout the first 24 hours postoperatively.Conclusions: Lower plasma concentrations of PAI-1 preoperatively and t-PA/PAI-1 complex postoperatively leads to higher plasma levels of D-dimer in association with more postoperative bleeding after cardiac surgery.publishersversionPeer reviewe

    Aortic root surgery in septuagenarians: impact of different surgical techniques

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To evaluate the impact and safety of different surgical techniques for aortic root replacement (ARR) on early and late morbidity and mortality in septuagenarians undergoing ARR.</p> <p>Methods</p> <p>Ninety-five patients (73.8 ± 3.2 years) were operated and divided into three groups according to the aortic root procedure; MECH-group (n = 51) patients with a mechanical composite graft, BIO-group (n = 22) patients with a customized biological composite graft, and REIMPL-group (n = 22) patients with a valve sparing aortic root reimplantation (David I). In 42.1% (40/95) of these patients the aortic arch was replaced. Follow-up was completed in 95.2% (79/83) of in-hospital survivors.</p> <p>Results</p> <p>Hospital mortality was 12.6% (12/95) in the entire population (MECH. 15.7% (8/51), BIO 19.7% (4/22), REIMPL 0% (0/22); p = 0.004). Two patients died intraoperatively. The most frequent postoperative complications were prolonged mechanical ventilation ((>48 h) in 16.8% (16/93) (MECH. 7% (7/51), BIO 36.4% (8/22), REIMPL 4.5% (1/22); p = 0.013) and rethoracotomy for postoperative bleeding in 12.6% (12/95) (MECH. 12% (6/51), BIO 22.7% (5/22), REIMPL 4.5% (1/22); p = 0.19). Nineteen late deaths (22.9%) (19/83) (MECH 34.8% (15/43), BIO 16.7% (3/18), REIMPL 4.5% (1/22); p = 0.012) occurred during a mean follow-up of 41 ± 42 months (MECH 48 ± 48 months, BIO 25 ± 37 months, REIMPL 40 ± 28 months, p = 0.028). Postoperative NYHA class decreased significantly (p = 0.017) and performance status (p = 0.027) increased for the entire group compared to preoperative values.</p> <p>Conclusion</p> <p>Our data indicate that valve sparing aortic root reimplantation is safe and effective in septuagenarians, and is associated with low early and late morbidity and mortality.</p
    corecore