84 research outputs found

    Recurrence of intestinal metaplasia and early neoplasia after endoscopic eradication therapy for Barrett’s esophagus: A systematic review and meta-analysis

    Get PDF
    Abstract Background Conflicting data exist with regard to recurrence rates of intestinal metaplasia (IM) and dysplasia after achieving complete eradication of intestinal metaplasia (CE-IM) in Barrett’s esophagus (BE) patients. Aim (i) To determine the incidence of recurrent IM and dysplasia achieving CE-IM and (ii) to compare recurrence rates between treatment modalities [radiofrequency ablation (RFA) with or without endoscopic mucosal resection (EMR) vs stepwise complete EMR (SRER)]. Methods A systematic search was performed for studies reporting on outcomes and estimates of recurrence rates after achieving CE-IM. Pooled incidence [per 100-patient-years (PY)] and risk ratios with 95 %CI were obtained. Heterogeneity was measured using the I 2 statistic. Subgroup analyses, decided a priori, were performed to explore heterogeneity in results. Results A total of 39 studies were identified (25-RFA, 13-SRER, and 2 combined). The pooled incidence of any recurrence was 7.5 (95 %CI 6.1 – 9.0)/100 PY with a pooled incidence of IM recurrence rate of 4.8 (95 %CI 3.8 – 5.9)/100 PY, and dysplasia recurrence rate of 2.0 (95 %CI 1.5 – 2.5)/100 PY. Compared to the SRER group, the RFA group had significantly higher overall [8.6 (6.7 – 10.5)/100 PY vs. 5.1 (3.1 – 7)/100 PY, P = 0.01] and IM recurrence rates [5.8 (4.3 – 7.3)/100 PY vs. 3.1 (1.7 – 4)/100 PY, P &lt; 0.01] with no difference in recurrence rates of dysplasia. Significant heterogeneity between studies was identified. The majority of recurrences were amenable to repeat endoscopic eradication therapy (EET). Conclusion The results of this study demonstrate that the incidence rates of overall, IM, and dysplasia recurrence rates post-EET are not inconsiderable and reinforce the importance of close surveillance after achieving CE-IM.</jats:p

    Ectopic cardiovascular fat in middle-aged men: effects of race/ethnicity, overall and central adiposity. The ERA JUMP study.

    Get PDF
    Background/objectivesHigher volumes of ectopic cardiovascular fat (ECF) are associated with greater risk of coronary heart disease (CHD). Identifying factors that are associated with ECF volumes may lead to new preventive efforts to reduce risk of CHD. Significant racial/ethnic differences exist for overall and central adiposity measures, which are known to be associated with ECF volumes. Whether racial/ethnic differences also exist for ECF volumes and their associations with these adiposity measures remain unclear.Subjects/methodsBody mass index (BMI), computerized tomography-measured ECF volumes (epicardial, pericardial and their summation) and visceral adipose tissue (VAT) were examined in a community-based sample of 1199 middle-aged men (24.2% Caucasians, 7.0% African-Americans, 23.6% Japanese-Americans, 22.0% Japanese, 23.2% Koreans).ResultsSignificant racial/ethnic differences existed in ECF volumes and their relationships with BMI and VAT. ECF volumes were the highest among Japanese-Americans and the lowest among African-Americans. The associations of BMI and VAT with ECF differed by racial/ethnic groups. Compared with Caucasians, for each 1-unit increase in BMI, African-Americans had lower, whereas Koreans had higher increases in ECF volumes (P-values&lt;0.05 for both). Meanwhile, compared with Caucasians, for each 1-unit increase in log-transformed VAT, African-Americans, Japanese-Americans and Japanese had similar increases, whereas Koreans had a lower increase in ECF volumes (P-value&lt;0.05).ConclusionsRacial/ethnic groups differed in their propensity to accumulate ECF at increasing level of overall and central adiposity. Future studies should evaluate whether reducing central adiposity or overall weight will decrease ECF volumes more in certain racial/ethnic groups. Evaluating these questions might help in designing race-specific prevention strategy of CHD risk associated with higher ECF

    Interobserver agreement for single operator choledochoscopy imaging: can we do better?

    Get PDF
    Background. The SpyGlass Direct Visualization System (Boston Scientific, Natick, MA) is routinely used during single operator choledochoscopy (SOC) to identify biliary lesions or strictures with a diagnostic accuracy up to 88%. The objective of this study was to determine the interobserver agreement (IOA) of modified scoring criteria for diagnosing biliary lesions/strictures. Methods. 27 SPY SOC video clips were reviewed and scored by 9 interventional endoscopists based on published criteria that included the presence and severity of surface structure, vasculature visualization, lesions, and findings. Results. Overall IOA was slight for all variables. The K statistics are as follows: surface (K = 0.12, SE = 0.02); vessels (K = 0.14, SE = 0.02); lesions (K = 0.11, SE = 0.02); findings (K = 0.08, SE = 0.03); and final diagnosis (K = 0.08, SE = 0.02). The IOA for findings and final diagnosis was also only slight. The final diagnosis was malignant (11), benign (11), and indeterminate (5). Conclusion. IOA using the modified criteria of SOC images was slight to almost poor. The average accuracy was less than 50%. These findings reaffirm that imaging criteria for benign and malignant biliary pathology need to be formally established and validated

    A comparison between endoscopic ultrasound-guided rendezvous and percutaneous biliary drainage after failed ERCP for malignant distal biliary obstruction

    Get PDF
    Background and study Aims: Selective biliary cannulation is unsuccessful in 5 % to 10 % of patients undergoing endoscopic retrograde cholangiopancreatography (ERCP) for malignant distal biliary obstruction (MDBO). Percutaneous biliary drainage (PBD) has been the gold standard, but endoscopic ultrasound guided rendezvous (EUSr) have been increasingly used for biliary decompression in this patient population. Our aim was to compare the initial success rate, long-term efficacy, and safety of PBD and EUSr in relieving MDBO after failed ERC Patients and methods: A retrospective study involving 50 consecutive patients who had an initial failed ERCP for MDBO. Twenty-five patients undergoing EUSr between 2008 – 2014 were compared to 25 patients who underwent PBD immediately prior to the introduction of EUSr at our center (2002 – 2008). Comparisons were made between the two groups with regard to technical success, duration of hospital stay and adverse event rates after biliary decompression. Results: The mean age at presentation was 66.5 (± 12.6 years), 28 patients (54.9 %) were female. The etiology of MDBO was pancreaticobiliary malignancy in 44 (88 %) and metastatic disease in 6 (12 %) cases. Biliary drainage was technically successful by EUSr in 19 (76 %) cases and by PBD in 25 (100 %) (P = 0.002). Median length of hospital stay after initial drainage was 1 day in the EUSr group vs 5 days in PBD group (P = 0.02). Repeat biliary intervention was required for 4 patients in the EUSr group and 15 in the PBD group (P = 0.001). Conclusions: Initial technical success with EUSr was significantly lower than with PBD, however when EUSr was successful, patients had a significantly shorter post-procedure hospital stay and required fewer follow-up biliary interventions. Meeting presentations: Annual Digestive Diseases Week 201

    A multicenter, prospective study of a new fully covered expandable metal biliary stent for the palliative treatment of malignant bile duct obstruction

    Get PDF
    Background and Study Aims. Endoscopic placement of self-expanding metal stents (SEMSs) is indicated for palliation of inoperable malignant biliary obstruction. A fully covered biliary SEMS (WallFlex Biliary RX Boston Scientific, Natick, USA) was assessed for palliation of extrahepatic malignant biliary obstruction. Patients and Methods. 58 patients were included in this prospective, multicenter series conducted under an FDA-approved IDE. Main outcome measurements included (1) absence of stent occlusion within six months or until death, whichever occurred first and (2) technical success, need for reintervention, bilirubin levels, stent patency, time to stent occlusion, and adverse events. Results. Technical success was achieved in 98% (57/58), with demonstrated acute removability in two patients. Adequate clinical palliation until completion of followup was achievedin 98% (54/55) of evaluable patients, with 1 reintervention due to stent obstruction after 142 days. Mean total bilirubin decreased from 8.9 mg/dL to 1.2 mg/dL at 1 month. Device-related adverse events were limited and included 2 cases of cholecystitis. One stent migrated following radiation therapy. Conclusions. The WallFlex Biliary fully covered stent yielded technically successful placement with uncomplicated acute removal where required, appropriate reduction in bilirubin levels, and low rates of stent migration and occlusion. This SEMS allows successful palliation of malignant extrahepatic biliary obstruction

    Clinical outcomes of EUS-guided drainage of debris-containing pancreatic pseudocysts: a large multicenter study

    Get PDF
    Background and study aims Data on clinical outcomes of endoscopic drainage of debris-free pseudocysts (PDF) versus pseudocysts containing solid debris (PSD) are very limited. The aims of this study were to compare treatment outcomes between patients with PDF vs. PSD undergoing endoscopic ultrasound (EUS)-guided drainage via transmural stents. Patients and methods Retrospective review of 142 consecutive patients with pseudocysts who underwent EUS-guided transmural drainage (TM) from 2008 to 2014 at 15 academic centers in the United States. Main outcome measures included TM technical success, treatment outcomes (symptomatic and radiologic resolution), need for endoscopic re-intervention at follow-up, and adverse events (AEs). Results TM was performed in 90 patients with PDF and 52 with PSD. Technical success: PDF 87 (96.7 %) vs. PSD 51 (98.1 %). There was no difference in the rates for endoscopic re-intervention (5.5 % in PDF vs. 11.5 % in PSD; P = 0.33) or AEs (12.2 % in PDF vs. 19.2 % in PSD; P = 0.33). Median long-term follow-up after stent removal was 297 days (interquartile range [IQR]: 59 - 424 days) for PDF and 326 days (IQR: 180 - 448 days) for PSD (P = 0.88). There was a higher rate of short-term radiologic resolution of PDF (45; 66.2 %) vs. PSD (21; 51.2 %) (OR = 0.30; 95 % CI: 0.13 - 0.72; P = 0.009). There was no difference in long-term symptomatic resolution (PDF: 70.4 % vs. PSD: 66.7 %; P = 0.72) or radiologic resolution (PDF: 68.9 % vs. PSD: 78.6 %; P = 0.72) Conclusions There was no difference in need for endoscopic re-intervention, AEs or long-term treatment outcomes in patients with PDF vs. PSD undergoing EUS-guided drainage with transmural stents. Based on these results, the presence of solid debris in pancreatic fluid collections does not appear to be associated with a poorer outcome

    Transpapillary drainage has no added benefit on treatment outcomes in patients undergoing EUS-guided transmural drainage of pancreatic pseudocysts: a large multicenter study

    Get PDF
    Background and Aims The need for transpapillary drainage (TPD) in patients undergoing transmural drainage (TMD) of pancreatic fluid collections (PFCs) remains unclear. The aims of this study were to compare treatment outcomes between patients with pancreatic pseudocysts undergoing TMD versus combined (TMD and TPD) drainage (CD) and to identify predictors of symptomatic and radiologic resolution. Methods This is a retrospective review of 375 consecutive patients with PFCs who underwent EUS-guided TMD from 2008 to 2014 at 15 academic centers in the United States. Main outcome measures included TMD and CD technical success, treatment outcomes (symptomatic and radiologic resolution) at follow-up, and predictors of treatment outcomes on logistic regression. Results A total of 375 patients underwent EUS-guided TMD of PFCs, of which 174 were pseudocysts. TMD alone was performed in 95 (55%) and CD in 79 (45%) pseudocysts. Technical success was as follows: TMD, 92 (97%) versus CD, 35 (44%) (P = .0001). There was no difference in adverse events between the TMD (15%) and CD (14%) cohorts (P = .23). Median long-term (LT) follow-up after transmural stent removal was 324 days (interquartile range, 72-493 days) for TMD and 201 days (interquartile range, 150-493 days) (P = .37). There was no difference in LT symptomatic resolution (TMD, 69% vs CD, 62%; P = .61) or LT radiologic resolution (TMD, 71% vs CD, 67%; P = .79). TPD attempt was negatively associated with LT radiologic resolution of pseudocyst (odds ratio, 0.11; 95% confidence interval, 0.02-0.8; P = .03). Conclusions TPD has no benefit on treatment outcomes in patients undergoing EUS-guided TMD of pancreatic pseudocysts and negatively affects LT resolution of PFCs

    Competence in Endoscopic Ultrasound and Endoscopic Retrograde Cholangiopancreatography, From Training Through Independent Practice.

    Get PDF
    BACKGROUND & AIMS: It is unclear whether participation in competency-based fellowship programs for endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) results in high-quality care in independent practice. We measured quality indicator (QI) adherence during the first year of independent practice among physicians who completed endoscopic training with a systematic assessment of competence. METHODS: We performed a prospective multicenter cohort study of invited participants from 62 training programs. In phase 1, 24 advanced endoscopy trainees (AETs), from 20 programs, were assessed using a validated competence assessment tool. We used a comprehensive data collection and reporting system to create learning curves using cumulative sum analysis that were shared with AETs and trainers quarterly. In phase 2, participating AETs entered data into a database pertaining to every EUS and ERCP examination during their first year of independent practice, anchored by key QIs. RESULTS: By the end of training, most AETs had achieved overall technical competence (EUS 91.7%, ERCP 73.9%) and cognitive competence (EUS 91.7%, ERCP 94.1%). In phase 2 of the study, 22 AETs (91.6%) participated and completed a median of 136 EUS examinations per AET and 116 ERCP examinations per AET. Most AETs met the performance thresholds for QIs in EUS (including 94.4% diagnostic rate of adequate samples and 83.8% diagnostic yield of malignancy in pancreatic masses) and ERCP (94.9% overall cannulation rate). CONCLUSIONS: In this prospective multicenter study, we found that although competence cannot be confirmed for all AETs at the end of training, most meet QI thresholds for EUS and ERCP at the end of their first year of independent practice. This finding affirms the effectiveness of training programs. Clinicaltrials.gov ID NCT02509416

    Competence in Endoscopic Ultrasound and Endoscopic Retrograde Cholangiopancreatography, From Training Through Independent Practice.

    Get PDF
    BACKGROUND & AIMS: It is unclear whether participation in competency-based fellowship programs for endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) results in high-quality care in independent practice. We measured quality indicator (QI) adherence during the first year of independent practice among physicians who completed endoscopic training with a systematic assessment of competence. METHODS: We performed a prospective multicenter cohort study of invited participants from 62 training programs. In phase 1, 24 advanced endoscopy trainees (AETs), from 20 programs, were assessed using a validated competence assessment tool. We used a comprehensive data collection and reporting system to create learning curves using cumulative sum analysis that were shared with AETs and trainers quarterly. In phase 2, participating AETs entered data into a database pertaining to every EUS and ERCP examination during their first year of independent practice, anchored by key QIs. RESULTS: By the end of training, most AETs had achieved overall technical competence (EUS 91.7%, ERCP 73.9%) and cognitive competence (EUS 91.7%, ERCP 94.1%). In phase 2 of the study, 22 AETs (91.6%) participated and completed a median of 136 EUS examinations per AET and 116 ERCP examinations per AET. Most AETs met the performance thresholds for QIs in EUS (including 94.4% diagnostic rate of adequate samples and 83.8% diagnostic yield of malignancy in pancreatic masses) and ERCP (94.9% overall cannulation rate). CONCLUSIONS: In this prospective multicenter study, we found that although competence cannot be confirmed for all AETs at the end of training, most meet QI thresholds for EUS and ERCP at the end of their first year of independent practice. This finding affirms the effectiveness of training programs. Clinicaltrials.gov ID NCT02509416

    A Prospective Multicenter Study Evaluating Learning Curves and Competence in Endoscopic Ultrasound and Endoscopic Retrograde Cholangiopancreatography Among Advanced Endoscopy Trainees: The Rapid Assessment of Trainee Endoscopy Skills (RATES) Study

    Get PDF
    Background and aims Based on the Next Accreditation System, trainee assessment should occur on a continuous basis with individualized feedback. We aimed to validate endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) learning curves among advanced endoscopy trainees (AETs) using a large national sample of training programs and to develop a centralized database that allows assessment of performance in relation to peers. Methods ASGE recognized training programs were invited to participate and AETs were graded on ERCP and EUS exams using a validated competency assessment tool that assesses technical and cognitive competence in a continuous fashion. Grading for each skill was done using a 4-point scoring system and a comprehensive data collection and reporting system was built to create learning curves using cumulative sum analysis. Individual results and benchmarking to peers were shared with AETs and trainers quarterly. Results Of the 62 programs invited, 20 programs and 22 AETs participated in this study. At the end of training, median number of EUS and ERCP performed/AET was 300 (range 155-650) and 350 (125-500). Overall, 3786 exams were graded (EUS:1137; ERCP–biliary 2280, pancreatic 369). Learning curves for individual endpoints, and overall technical/cognitive aspects in EUS and ERCP demonstrated substantial variability and were successfully shared with all programs. The majority of trainees achieved overall technical (EUS: 82%; ERCP: 60%) and cognitive (EUS: 76%; ERCP: 100%) competence at conclusion of training. Conclusions These results demonstrate the feasibility of establishing a centralized database to report individualized learning curves and confirm the substantial variability in time to achieve competence among AETs in EUS and ERCP
    • …
    corecore