393 research outputs found

    Assessment of reporting quality of conference abstracts in sports injury prevention according to CONSORT and STROBE criteria and their subsequent publication rate as full papers

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The preliminary results of a study are usually presented as an abstract in conference meetings. The reporting quality of those abstracts and the relationship between their study designs and full paper publication rate is unknown. We hypothesized that randomized controlled trials are more likely to be published as full papers than observational studies.</p> <p>Methods</p> <p>154 oral abstracts presented at the World Congress of Sports Injury Prevention 2005 Oslo and the corresponding full paper publication were identified and analysed. The main outcome measures were frequency of publication, time to publication, impact factor, CONSORT (for Consolidated Standards of Reporting Trials) score, STROBE (for Strengthening the Reporting of Observational Studies in Epidemiology) score, and minor and major inconsistencies between the abstract and the full paper publication.</p> <p>Results</p> <p>Overall, 76 of the 154 (49%) presented abstracts were published as full papers in a peer-reviewed journal with an impact factor of 1.946 ± 0.812. No significant difference existed between the impact factor for randomized controlled trials (2.122 ± 1.015) and observational studies (1.913 ± 0.765, p = 0.469). The full papers for the randomized controlled trials were published after an average (SD) of 17 months (± 13 months); for observational studies, the average (SD) was 12 months (± 14 months) (p = 0.323). A trend was observed in this study that a higher percentage of randomized controlled trial abstracts were published as full papers (71% vs. 47%, p = 0.078) than observational trials. The reporting quality of abstracts, published as full papers, significantly increased compared to conference abstracts both in randomized control studies (CONSORT: 5.7 ± 0.7 to 7.2 ± 1.3; p = 0.018, CI -2.7 to -0.32) and in observational studies (STROBE: 8.2 ± 1.3 to 8.6 ± 1.4; p = 0.007, CI -0.63 to -0.10). All of the published abstracts had at least one minor inconsistency (title, authors, research center, outcome presentation, conclusion), while 65% had at least major inconsistencies (study objective, hypothesis, study design, primary outcome measures, sample size, statistical analysis, results, SD/CI). Comparing the results of conference and full paper; results changed in 90% vs. 68% (randomized, controlled studies versus observational studies); data were added (full paper reported more result data) in 60% vs. 30%, and deleted (full paper reported fewer result data) in 40% vs. 30%.</p> <p>Conclusions</p> <p>No significant differences with respect to type of study (randomized controlled versus observational), impact factor, and time to publication existed for the likelihood that a World Congress of Sports Injury conference abstract could be published as a full paper.</p

    Simplified mathematical model of proton exchange membrane fuel cell based on horizon fuel cell stack

    Get PDF
    This paper presents a simplified zero-dimensional mathematical model for a self-humidifying proton exchange membrane (PEM) fuel cell stack of 1 kW. The model incorporates major electric and thermodynamic variables and parameters involved in the operation of the PEM fuel cell under different operational conditions. Influence of each of these parameters and variables upon the operation and the performance of the PEM fuel cell are investigated. The mathematical equations are modeled by using Matlab–Simulink tools in order to simulate the operation of the developed model with a commercial available 1 kW horizon PEM fuel cell stack (H-1000), which is used for the purposes of model validation and tuning of the developed model. The model can be extrapolated to higher wattage fuel cells of similar arrangements. New equation is presented to determine the impact of using air to supply the PEM fuel cell instead of pure oxygen upon the concentration losses and the output voltage when useful current is drawn from it

    Successful outcome of six-level cervicothoracic corpectomy and circumferential reconstruction: case report and review of literature on multilevel cervicothoracic corpectomy

    Get PDF
    The authors report the successful outcome of a six-level corpectomy across the cervico-thoracic spine with circumferential reconstruction in a patient with extensive osteomyelitis of the cervical and upper thoracic spine. To the authors’ knowledge, this is the first report of a corpectomy extending across six levels of the cervico-thoracic spine. Clinical relevance: the authors recommend anterior cage and plate-assisted reconstruction and additional posterior instrumentation using modern spinal surgical techniques and implants

    Remote monitoring and follow-up of cardiovascular implantable electronic devices in the Netherlands: An expert consensus report of the Netherlands Society of Cardiology

    Get PDF
    Remote monitoring of cardiac implanted electronic devices (CIED: pacemaker, cardiac resynchronisation therapy device and implantable cardioverter defibrillator) has been developed for technical control and follow-up using transtelephonic data transmission. In addition, automatic or patient-triggered alerts are sent to the cardiologist or allied professional who can respond if necessary with various interventions. The advantage of remote monitoring appears obvious in impending CIED failures and suspected symptoms but is less likely in routine follow-up of CIED. For this follow-up the indications, quality of care, cost-effectiveneness and patient satisfaction have to be determined before remote CIED monitoring can be applied in daily practice. Nevertheless remote CIED monitoring is expanding rapidly in the Netherlands without professional agreements about methodology, responsibilities of all the parties involved and that of the device patient, and reimbursement. The purpose of this consensus document on remote CIED monitoring and follow-up is to lay the base for a nationwide, uniform implementation in the Netherlands. This report describes the technical communication, current indications, benefits and limitations of remote CIED monitoring and follow-up, the role of the patient and device manufacturer, and costs and reimbursement. The view of cardiology experts and of other disciplines in conjunction with literature was incorporated in a preliminary series of recommendations. In addition, an overview of the questions related to remote CIED monitoring that need to be answered is given. This consensus document can be used for future guidelines for the Dutch profession

    Innovation, technology and user experience in museums: insights from scientific literature

    Get PDF
    Museums play an important role in preserving the heritage and cultural legacy of humanity, however, one of their main weaknesses in regards the user is their static nature. At present, and in the face of the development of diverse technologies and the ease of access to information, museums have upgraded their implementation of technologies aimed at improving the user experience, trying more and more to access younger audiences with a sensitivity and natural capacity for the management of new technologies. This work identifies trends in the use of technological tools by museums worldwide and the effect of these on the user or visitor experience through a review of scientific literature. To complete the work, we performed a search of the publications in the Scopus® referencing database, and downloaded, processed, and visualized the data using the VOSviewer® tool. The main trends identified in this context of analysis are related to the role of museums with the development and improvement of the user experience; orientation to young audiences and innovation driven by the user through Interactive Systems, digital games, QR Codes, apps, augmented reality, virtual reality and gamification, among others. The objective of the implementation of new technologies in the context of museums is to satisfy the needs of contemporary communication, for all types of content and aimed at an increasingly digital audience, in order to ensure positive interaction and feedback from ideas with social and cultural changes

    Update on cervical disc arthroplasty: where are we and where are we going?

    Get PDF
    Despite the very good results of anterior cervical discectomy and fusion, there are concerns of adjacent level degeneration. For this reason, interest has grown in the potential for motion sparing alternatives. Cervical disc arthroplasty is thus evolving as a potential alternative to fusion. Specific design characteristic and implants will be reviewed and outcomes summarized

    Impact of mediastinal, liver and lung 123I-metaiodobenzylguanidine (123I-MIBG) washout on calculated 123I-MIBG myocardial washout

    Get PDF
    PURPOSE: In planar (123)I-metaiodobenzylguanidine ((123)I-MIBG) myocardial imaging mediastinum (M) activity is often used as a background correction in calculating "washout" (WO). However, the most likely sources for counts that might produce errors in estimating myocardial (Myo) activity are lung (Lu) and liver (Li), which typically have higher counts/pixel (cpp) than M. The present study investigated the relationship between changes in Lu, Li and Myo activity between early and late planar (123)I-MIBG images, with comparison to M as the best estimator of non-specific background activity. METHODS: Studies on 98 subjects with both early (e) and late (l) planar (123)I-MIBG images were analysed. There were 68 subjects with chronic heart failure (CHF), 14 with hypertension (HTN) but no known heart disease and 16 controls (C). For each image, regions of interest (ROIs) were drawn: an irregular whole Myo, Lu, upper M and Li. For each ROI, WO was calculated as [(cpp(e)-cpp(l:decay corrected))/cpp(e)]x100%. RESULTS: Multivariable forward stepwise regression analysis showed that overall a significant proportion of the variation in Myo WO could be explained by a model containing M WO and Lu WO (37%, p < 0.001). Only in controls was M WO the sole variable explaining a significant proportion of the variation in Myo WO (27%, p = 0.023). CONCLUSION: Although increased Myo WO in CHF subjects reflects disease severity, part of the count differences measured on planar (123)I-MIBG myocardial images likely reflects changes in the adjacent and surrounding Lu tissue. The results for the controls suggest that this is the only group where a mediastinum correction alone may be appropriate for cardiac WO calculation

    Clinical performance and radiation dosimetry of no-carrier-added vs carrier-added 123I-metaiodobenzylguanidine (MIBG) for the assessment of cardiac sympathetic nerve activity

    Get PDF
    Purpose We hypothesized that assessment of myocardial sympathetic activity with no-carrier-added (nca) I-123-metaiodobenzylguanidine (MIBG) compared to carrier-added (ca) I-123-MIBG would lead to an improvement of clinical performance without major differences in radiation dosimetry. Methods In nine healthy volunteers, 15 min and 4 h planar thoracic scintigrams and conjugate whole-body scans were performed up to 48 h following intravenous injection of 185 MBq I-123-MIBG. The subjects were given both nca and ca I-123-MIBG. Early heart/mediastinal ratios (H/M), late H/M ratios and myocardial washout were calculated. The fraction of administered activity in ten source organs was quantified from the attenuation-corrected geometric mean counts in conjugate views. Radiation-absorbed doses were estimated with OLINDA/EXM software. Results Both early and late H/M were higher for nca I-123-MIBG (ca I-123-MIBG early H/M 2.46 +/- 0.15 vs nca I-123-MIBG 2.84 +/- 0.15, p = 0.001 and ca I-123-MIBG late H/M 2.69 +/- 0.14 vs nca I-123-MIBG 3.34 +/- 0.18, p = 0.002). Myocardial washout showed a longer retention time for nca I-123-MIBG (p <0.001). The effective dose equivalent (adult male model) for nca I-123-MIBG was similar to that for ca I-123-MIBG (0.025 +/- 0.002 mSv/MBq vs 0.026 +/- 0.002 mSv/MBq, p = 0.055, respectively). Conclusion No-carrier-added I-123-MIBG yields a higher relative myocardial uptake and is associated with a higher myocardial retention. This difference between nca I-123-MIBG and ca I-123-MIBG in myocardial uptake did not result in major differences in estimated absorbed doses. Therefore, nca I-123-MIBG is to be preferred over ca I-123-MIBG for the assessment of cardiac sympathetic activit
    corecore