31 research outputs found

    Point-of-care tests detecting HIV nucleic acids for diagnosis of HIV-1 or HIV-2 infection in infants and children aged 18 months or less

    Get PDF
    BACKGROUND: The standard method of diagnosing HIV in infants and children less than 18 months is with a nucleic acid amplification test reverse transcriptase polymerase chain reaction test (NAT RT-PCR) detecting viral ribonucleic acid (RNA). Laboratory testing using the RT-PCR platform for HIV infection is limited by poor access, logistical support, and delays in relaying test results and initiating therapy in low-resource settings. The use of rapid diagnostic tests at or near the point-of-care (POC) can increase access to early diagnosis of HIV infection in infants and children less than 18 months of age and timely initiation of antiretroviral therapy (ART). OBJECTIVES: To summarize the diagnostic accuracy of point-of-care nucleic acid-based testing (POC NAT) to detect HIV-1/HIV-2 infection in infants and children aged 18 months or less exposed to HIV infection. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (until 2 February 2021), MEDLINE and Embase (until 1 February 2021), and LILACS and Web of Science (until 2 February 2021) with no language or publication status restriction. We also searched conference websites and clinical trial registries, tracked reference lists of included studies and relevant systematic reviews, and consulted experts for potentially eligible studies. SELECTION CRITERIA: We defined POC tests as rapid diagnostic tests conducted at or near the patient site. We included any primary study that compared the results of a POC NAT to a reference standard of laboratory NAT RT-PCR or total nucleic acid testing to detect the presence or absence of HIV infection denoted by HIV viral nucleic acids in infants and children aged 18 months or less who were exposed to HIV-1/HIV-2 infection. We included cross-sectional, prospective, and retrospective study designs and those that provided sufficient data to create the 2 × 2 table to calculate sensitivity and specificity. We excluded diagnostic case control studies with healthy controls. DATA COLLECTION AND ANALYSIS: We extracted information on study characteristics using a pretested standardized data extraction form. We used the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) tool to assess the risk of bias and applicability concerns of the included studies. Two review authors independently selected and assessed the included studies, resolving any disagreements by consensus. The unit of analysis was the participant. We first conducted preliminary exploratory analyses by plotting estimates of sensitivity and specificity from each study on forest plots and in receiver operating characteristic (ROC) space. For the overall meta-analyses, we pooled estimates of sensitivity and specificity using the bivariate meta-analysis model at a common threshold (presence or absence of infection). MAIN RESULTS: We identified a total of 12 studies (15 evaluations, 15,120 participants). All studies were conducted in sub-Saharan Africa. The ages of included infants and children in the evaluations were as follows: at birth (n = 6), ≤ 12 months (n = 3), ≤ 18 months (n = 5), and ≤ 24 months (n = 1). Ten evaluations were field evaluations of the POC NAT test at the point of care, and five were laboratory evaluations of the POC NAT tests.The POC NAT tests evaluated included Alere q HIV-1/2 Detect qualitative test (recently renamed m-PIMA q HIV-1/2 Detect qualitative test) (n = 6), Xpert HIV-1 qualitative test (n = 6), and SAMBA HIV-1 qualitative test (n = 3). POC NAT pooled sensitivity and specificity (95% confidence interval (CI)) against laboratory reference standard tests were 98.6% (96.1 to 99.5) (15 evaluations, 1728 participants) and 99.9% (99.7 to 99.9) (15 evaluations, 13,392 participants) in infants and children ≤ 18 months. Risk of bias in the included studies was mostly low or unclear due to poor reporting. Five evaluations had some concerns for applicability for the index test, as they were POC tests evaluated in a laboratory setting, but there was no difference detected between settings in sensitivity (-1.3% (95% CI -4.1 to 1.5)); and specificity results were similar. AUTHORS' CONCLUSIONS: For the diagnosis of HIV-1/HIV-2 infection, we found the sensitivity and specificity of POC NAT tests to be high in infants and children aged 18 months or less who were exposed to HIV infection

    Rapid molecular tests for tuberculosis and tuberculosis drug resistance: a qualitative evidence synthesis of recipient and provider views

    Get PDF
    BACKGROUND: Programmes that introduce rapid molecular tests for tuberculosis and tuberculosis drug resistance aim to bring tests closer to the community, and thereby cut delay in diagnosis, ensure early treatment, and improve health outcomes, as well as overcome problems with poor laboratory infrastructure and inadequately trained personnel. Yet, diagnostic technologies only have an impact if they are put to use in a correct and timely manner. Views of the intended beneficiaries are important in uptake of diagnostics, and their effective use also depends on those implementing testing programmes, including providers, laboratory professionals, and staff in health ministries. Otherwise, there is a risk these technologies will not fit their intended use and setting, cannot be made to work and scale up, and are not used by, or not accessible to, those in need. OBJECTIVES: To synthesize end-user and professional user perspectives and experiences with low-complexity nucleic acid amplification tests (NAATs) for detection of tuberculosis and tuberculosis drug resistance; and to identify implications for effective implementation and health equity. SEARCH METHODS: We searched MEDLINE, Embase, CINAHL, PsycInfo and Science Citation Index Expanded databases for eligible studies from 1 January 2007 up to 20 October 2021. We limited all searches to 2007 onward because the development of Xpert MTB/RIF, the first rapid molecular test in this review, was completed in 2009. SELECTION CRITERIA: We included studies that used qualitative methods for data collection and analysis, and were focused on perspectives and experiences of users and potential users of low-complexity NAATs to diagnose tuberculosis and drug-resistant tuberculosis. NAATs included Xpert MTB/RIF, Xpert MTB/RIF Ultra, Xpert MTB/XDR, and the Truenat assays. Users were people with presumptive or confirmed tuberculosis and drug-resistant tuberculosis (including multidrug-resistant (MDR-TB)) and their caregivers, healthcare providers, laboratory technicians and managers, and programme officers and staff; and were from any type of health facility and setting globally. MDR-TB is tuberculosis caused by resistance to at least rifampicin and isoniazid, the two most effective first-line drugs used to treat tuberculosis. DATA COLLECTION AND ANALYSIS: We used a thematic analysis approach for data extraction and synthesis, and assessed confidence in the findings using GRADE CERQual approach. We developed a conceptual framework to illustrate how the findings relate. MAIN RESULTS: We found 32 studies. All studies were conducted in low- and middle-income countries. Twenty-seven studies were conducted in high-tuberculosis burden countries and 21 studies in high-MDR-TB burden countries. Only one study was from an Eastern European country. While the studies covered a diverse use of low-complexity NAATs, in only a minority of studies was it used as the initial diagnostic test for all people with presumptive tuberculosis. We identified 18 review findings and grouped them into three overarching categories. Critical aspects users value People with tuberculosis valued reaching diagnostic closure with an accurate diagnosis, avoiding diagnostic delays, and keeping diagnostic-associated cost low. Similarly, healthcare providers valued aspects of accuracy and the resulting confidence in low-complexity NAAT results, rapid turnaround times, and keeping cost to people seeking a diagnosis low. In addition, providers valued diversity of sample types (for example, gastric aspirate specimens and stool in children) and drug resistance information. Laboratory professionals appreciated the improved ease of use, ergonomics, and biosafety of low-complexity NAATs compared to sputum microscopy, and increased staff satisfaction. Challenges reported to realizing those values People with tuberculosis and healthcare workers were reluctant to test for tuberculosis (including MDR-TB) due to fears, stigma, or cost concerns. Thus, low-complexity NAAT testing is not implemented with sufficient support or discretion to overcome barriers that are common to other approaches to testing for tuberculosis. Delays were reported at many steps of the diagnostic pathway owing to poor sample quality; difficulties with transporting specimens; lack of sufficient resources; maintenance of low-complexity NAATs; increased workload; inefficient work and patient flows; over-reliance on low-complexity NAAT results in lieu of clinical judgement; and lack of data-driven and inclusive implementation processes. These challenges were reported to lead to underutilization.  Concerns for access and equity The reported concerns included sustainable funding and maintenance and equitable use of resources to access low-complexity NAATs, as well as conflicts of interest between donors and people implementing the tests. Also, lengthy diagnostic delays, underutilization of low-complexity NAATs, lack of tuberculosis diagnostic facilities in the community, and too many eligibility restrictions hampered access to prompt and accurate testing and treatment. This was particularly the case for vulnerable groups, such as children, people with MDR-TB, or people with limited ability to pay. We had high confidence in most of our findings. AUTHORS' CONCLUSIONS: Low-complexity diagnostics have been presented as a solution to overcome deficiencies in laboratory infrastructure and lack of skilled professionals. This review indicates this is misleading. The lack of infrastructure and human resources undermine the added value new diagnostics of low complexity have for recipients and providers. We had high confidence in the evidence contributing to these review findings. Implementation of new diagnostic technologies, like those considered in this review, will need to tackle the challenges identified in this review including weak infrastructure and systems, and insufficient data on ground level realities prior and during implementation, as well as problems of conflicts of interest in order to ensure equitable use of resources

    Variation in the observed effect of Xpert MTB/RIF testing for tuberculosis on mortality: A systematic review and analysis of trial design considerations [version 2; peer review: 3 approved]

    Get PDF
    Background: Most studies evaluating the effect of Xpert MTB/RIF testing for tuberculosis (TB) concluded that it did not reduce overall mortality compared to usual care. We conducted a systematic review to assess whether key study design and execution features contributed to earlier identification of patients with TB and decreased pre-treatment loss to follow-up, thereby reducing the potential impact of Xpert MTB/RIF testing. / Methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, and Scopus for literature published from 1st January 2009 to February 2019. We included all primary intervention studies that had evaluated the effect of Xpert MTB/RIF on mortality compared to usual care in participants with presumptive pulmonary TB. We critically reviewed features of included studies across: Study setting and context, Study population, Participant recruitment and enrolment, Study procedures, and Study follow-up. / Results: We included seven randomised and one non-randomised study. All included studies demonstrated relative reductions in overall mortality in the Xpert MTB/RIF arm ranging from 6% to 40%. However, mortality reduction was reported to be statistically significant in two studies. Study features that could explain the lack of observed effect on mortality included: the higher quality of care at study sites; inclusion of patients with a higher pre-test probability of TB leading to higher than expected empirical rates; performance of additional diagnostic testing not done in usual care leading to increased TB diagnosis or empiric treatment initiation; the recruitment of participants likely to return for follow-up; and involvement of study staff in ensuring adherence with care and follow-up. / Conclusion: Most studies of Xpert MTB/RIF were designed and conducted in a manner that resulted in more patients being diagnosed and treated for TB, minimising the potential difference in mortality Xpert MTB/RIF testing could have achieved compared to usual care

    Interpreting ambiguous ‘trace’ results in Schistosoma mansoni CCA Tests: Estimating sensitivity and specificity of ambiguous results with no gold standard

    Get PDF
    Background The development of new diagnostics is an important tool in the fight against disease. Latent Class Analysis (LCA) is used to estimate the sensitivity and specificity of tests in the absence of a gold standard. The main field diagnostic for Schistosoma mansoni infection, Kato-Katz (KK), is not very sensitive at low infection intensities. A point-of-care circulating cathodic antigen (CCA) test has been shown to be more sensitive than KK. However, CCA can return an ambiguous ‘trace’ result between ‘positive’ and ‘negative’, and much debate has focused on interpretation of traces results. Methodology/Principle findings We show how LCA can be extended to include ambiguous trace results and analyse S. mansoni studies from both Côte d’Ivoire (CdI) and Uganda. We compare the diagnostic performance of KK and CCA and the observed results by each test to the estimated infection prevalence in the population. Prevalence by KK was higher in CdI (13.4%) than in Uganda (6.1%), but prevalence by CCA was similar between countries, both when trace was assumed to be negative (CCAtn: 11.7% in CdI and 9.7% in Uganda) and positive (CCAtp: 20.1% in CdI and 22.5% in Uganda). The estimated sensitivity of CCA was more consistent between countries than the estimated sensitivity of KK, and estimated infection prevalence did not significantly differ between CdI (20.5%) and Uganda (19.1%). The prevalence by CCA with trace as positive did not differ significantly from estimates of infection prevalence in either country, whereas both KK and CCA with trace as negative significantly underestimated infection prevalence in both countries. Conclusions Incorporation of ambiguous results into an LCA enables the effect of different treatment thresholds to be directly assessed and is applicable in many fields. Our results showed that CCA with trace as positive most accurately estimated infection prevalence

    Point-of-care viral load tests to detect high HIV viral load in people living with HIV/AIDS attending health facilities

    No full text
    Background: Viral load (VL) testing in people living with HIV (PLHIV) helps to monitor antiretroviral therapy (ART). VL is still largely tested using central laboratory-based platforms, which have long test turnaround times and involve sophisticated equipment. VL tests with point-of-care (POC) platforms capable of being used near the patient are potentially easy to use, give quick results, are cost-effective, and could replace central or reference VL testing platforms. Objectives: To estimate the diagnostic accuracy of POC tests to detect high viral load levels in PLHIV attending healthcare facilities. Search methods: We searched eight electronic databases using standard, extensive Cochrane search methods, and did not use any language, document type, or publication status limitations. We also searched the reference lists of included studies and relevant systematic reviews, and consulted an expert in the field from the World Health Organization (WHO) HIV Department for potentially relevant studies. The latest search was 23 November 2020. Selection criteria: We included any primary study that compared the results of a VL test with a POC platform to that of a central laboratory-based reference test to detect high viral load in PLHIV on HIV/AIDS care or follow-up. We included all forms of POC tests for VL as defined by study authors, regardless of the healthcare facility in which the test was conducted. We excluded diagnostic case-control studies with healthy controls and studies that did not provide sufficient data to create the 2 × 2 tables to calculate sensitivity and specificity. We did not limit our study inclusion to age, gender, or geographical setting. Data collection and analysis: Two review authors independently screened the titles, abstracts, and full texts of the search results to identify eligible articles. They also independently extracted data using a standardized data extraction form and conducted risk of bias assessment using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Using participants as the unit of analysis, we fitted simplified univariable models for sensitivity and specificity separately, employing a random-effects model to estimate the summary sensitivity and specificity at the current and commonly reported World Health Organization (WHO) threshold (≥ 1000 copies/mL). The bivariate models did not converge to give a model estimate. Main results: We identified 18 studies (24 evaluations, 10,034 participants) defining high viral loads at main thresholds ≥ 1000 copies/mL (n = 20), ≥ 5000 copies/mL (n = 1), and ≥ 40 copies/mL (n = 3). All evaluations were done on samples from PLHIV retrieved from routine HIV/AIDS care centres or health facilities. For clinical applicability, we included 14 studies (20 evaluations, 8659 participants) assessing high viral load at the clinical threshold of ≥ 1000 copies/mL in the meta-analyses. Of these, sub-Saharan Africa, Europe, and Asia contributed 16, three, and one evaluation respectively. All included participants were on ART in only nine evaluations; in the other 11 evaluations the proportion of participants on ART was either partial or not clearly stated. Thirteen evaluations included adults only (n = 13), five mixed populations of adults and children, whilst in the remaining two the age of included populations was not clearly stated. The majority of evaluations included commercially available tests (n = 18). Ten evaluations were POC VL tests conducted near the patient in a peripheral or onsite laboratory, whilst the other 10 were evaluations of POC VL tests in a central or reference laboratory setting. The test types evaluated as POC VL tests included Xpert HIV-1 Viral Load test (n = 8), SAMBA HIV-1 Semi-Q Test (n = 9), Alere Q NAT prototype assay for HIV-1 (n = 2) and m-PIMA HIV-1/2 Viral Load test (n = 1). The majority of evaluations (n = 17) used plasma samples, whilst the rest (n = 3) utilized whole blood samples. Pooled sensitivity (95% confidence interval (CI)) of POC VL at a threshold of ≥ 1000 copies/mL was 96.6% (94.8 to 97.8) (20 evaluations, 2522 participants), and pooled specificity (95% CI) was 95.7% (90.8 to 98.0) (20 evaluations, 6137 participants). Median prevalence for high viral load (≥ 1000 copies/mL) (n = 20) was 33.4% (range 6.9% to 88.5%). Limitations. The risk of bias was mostly assessed as unclear across the four domains due to incomplete reporting. Authors' conclusions: We found POC VL to have high sensitivity and high specificity for the diagnosis of high HIV viral load in PLHIV attending healthcare facilities at a clinical threshold of ≥ 1000 copies/mL
    corecore