14 research outputs found

    Management of Coronary Artery Perforation

    No full text
    Coronary artery perforation (CAP) is a rare but potentially life-threatening complication of percutaneous coronary intervention (PCI), however if recognized and managed promptly, its adverse consequences can be minimized. Risk factors for CAP include the use of advanced PCI technique (such as atherectomy and chronic total occlusion interventions) and treatment of severely calcified lesions. There are 3 major types of CAP depending on location: (a) large vessel perforation, (b) distal vessel perforation, and (c) collateral perforation. Large vessel perforation is usually treated with implantation of a covered stent, whereas distal and collateral vessel perforations are usually treated with coil or fat embolization. In this article we provide a state-of-the-art overview of the contemporary management of CAP

    The efficacy of coronary sinus reducer in patients with refractory angina—A systematic review of the literature

    No full text
    Objectives: The aim of our systematic review was to investigate the efficacy of coronary sinus (CS) reducer device in patients with refractory angina. Background: The CS reducer device provides a therapeutic option for patients with coronary artery disease who are not suitable for revascularization. Methods: Two independent investigators (GB and GT) systematically searched the Medline and Cochrane library databases for studies describing the efficacy and safety of the CS reducer in patients with refractory angina from January 1, 2000 until May 12, 2018 using the following terms: “coronary sinus (reducer OR reducing) device.” Efficacy was defined as ≥1 unit improvement in the Canadian cardiovascular society (CCS) score. Results: Our search strategy provided six studies (five observational studies and one randomized clinical trial) with 196 patients. The CS reducer device was effective in 146/186 (78.5%) patients. CCS score improved from 3.2 at baseline to 1.9 after 8.6 months of follow-up. The efficacy of CS reducer device was also demonstrated as an improvement in Seattle Angina Questionnaire score, dobutamine echocardiography, thalium single-photon emission computed tomography perfusion studies, 6-min-walk test and myocardial perfusion reserve index. Implantation failed in 4 of 196 (2%) patients and 5 patients (2.5%) had a complication during 30-day follow-up. Conclusions: The CS reducer is a promising treatment option for patients with refractory angina who are not candidates for revascularization. However, larger randomized control trials with long-term follow-up are needed to elucidate its role. © 2018 Wiley Periodicals, Inc

    Temporal changes of noninvasive electrocardiographic risk factors for sudden cardiac death in post-myocardial infarction patients with preserved ejection fraction: Insights from the PRESERVE-EF study

    No full text
    Background: Several noninvasive risk factors (NIRFs) have been proposed for sudden cardiac death risk stratification in post-myocardial infarction (post-MI) patients with preserved ejection fraction (EF). However, it remains unclear if these factors change over time. Methods: We evaluated seven electrocardiographic NIRFs as they were described in the PRESERVE-EF trial in 80 post-MI patients with EF ≥ 40%, at least 40 days after revascularization and 1 year later. Results: Mean patient age was 56 ± 10 years, and 88% were men. Mean EF was 50 ± 5%. The prevalence of (a) positive late potentials (27.5% vs. 28.8%, p =.860), (b) >30 premature ventricular complexes/hour (8.8% vs. 11.3%, p =.598), (c) nonsustained ventricular tachycardia (8.8% vs. 5%, p =.349), (d) standard deviation of normal RR intervals <75 ms (3.8% vs. 3.8%, p = 1.000), (e) QTc derived from 24-hr electrocardiography >440 ms (men) or >450 ms (women) (17.5% vs. 17.5%, p = 1.000), (f) deceleration capacity ≤4.5 ms and heart rate turbulence onset ≥0% and slope ≤2.5 ms (2.5% vs. 3.8%. p = 1.000), and (g) ambulatory T-wave alternans ≥65 μV in two Holter channels (6.3% vs. 6.3%, p = 1.000) were similar between the two measurements. However, five patients (6.3%) without any NIRFs during the first assessment had at least one positive NIRF at the second assessment and six patients (7.5%) with at least one NIRF at baseline had no positive NIRFs at 1 year. Conclusions: While the prevalence of the examined electrocardiographic NIRFs between the two examinations was similar on a population basis, some patients without NIRFs at baseline developed NIRFs at 1 year and vice versa, highlighting the need for risk factor reassessment during follow-up. © 2019 Wiley Periodicals, Inc

    2-year outcomes after stenting of lipid-rich and nonrich coronary plaques

    No full text
    Background: Autopsy studies suggest that implanting stents in lipid-rich plaque (LRP) may be associated with adverse outcomes. Objectives: The purpose of this study was to evaluate the association between LRP detected by near-infrared spectroscopy (NIRS) and clinical outcomes in patients with coronary artery disease treated with contemporary drug-eluting stents. Methods: In this prospective, multicenter registry, NIRS was performed in patients undergoing coronary angiography and possible percutaneous coronary intervention (PCI). Lipid core burden index (LCBI) was calculated as the fraction of pixels with the probability of LRP >0.6 within a region of interest. MaxLCBI4mm was defined as the maximum LCBI within any 4-mm-long segment. Major adverse cardiac events (MACE) included cardiac death, myocardial infarction, definite or probable stent thrombosis, or unplanned revascularization or rehospitalization for progressive angina or unstable angina. Events were subcategorized as culprit (treated) lesion–related, nonculprit (untreated) lesion–related, or indeterminate. Results: Among 1,999 patients who were enrolled in the COLOR (Chemometric Observations of Lipid Core Plaques of Interest in Native Coronary Arteries Registry), PCI was performed in 1,621 patients and MACE occurred in 18.0% of patients, of which 8.3% were culprit lesion–related, 10.7% were nonculprit lesion–related, and 3.1% were indeterminate during 2-year follow-up. Complications from NIRS imaging occurred in 9 patients (0.45%), which resulted in 1 peri-procedural myocardial infarction and 1 emergent coronary bypass. Pre-PCI NIRS imaging was obtained in 1,189 patients, and the 2-year rate of culprit lesion–related MACE was not significantly associated with maxLCBI4mm (hazard ratio of maxLCBI4mm per 100: 1.06; 95% confidence interval: 0.96 to 1.17; p = 0.28) after adjusting clinical and procedural factors. Conclusions: Following PCI with contemporary drug-eluting stents, stent implantation in NIRS-defined LRPs was not associated with increased periprocedural or late adverse outcomes compared with those without significant lipid.Myong HwaYamamoto, Akiko Maehara, Gregg W.Stone, Annapoorna S.Kini, Emmanouil S.Brilakis ... Stephen Nicholl
    corecore