147 research outputs found

    Electric field gradients in MgB2_2 synthesized at high pressure: 111^111Cd TDPAC study and ab initio calculation

    Full text link
    We report the high-pressure synthesis of novel superconductor MgB2_2 and some related compounds. The superconducting transition temperature of our samples of MgB2_2 is equal to 36.6 K. The MgB2_2 lattice parameters determined via X-ray diffraction are in excellent agreement with results of our ab initio calculations. The time-differential perturbed angular correlation (TDPAC) experiments demonstrate a small increase in quadrupole frequency of 111^111Cd probe with decreasing temperature from 293 to 4.2 K. The electric field gradient (EFG) at the B site calculated from first principles is in fair agreement with EFG obtained from 11^11B NMR spectra of MgB2_2 reported in the literature. It is also very close to EFG found in our 111^111Cd TDPAC measurements, which suggests that the 111^111Cd probe substitutes for boron in the MgB2_2 lattice.Comment: 10 pages, 3 figure

    Electron accelerator for energy up to 5.0 MeV and beam power up to 50 kW with Х-ray converter

    No full text
    The paper describes the industrial electron accelerator ILU-10 for electron energy up to 5 MeV and beam power up to 50 kW specially designed for use in industrial applications. The ILU-10 accelerator generates the vertical electron beam. The beam line turns the beam through an angle of 90° and transports the beam to the vertically posed Xray converter to generate the horizontal beam of X-rays.Приводиться опис прискорювача електронів ІЛУ-10 на енергію 5 МеВ потужністю 50 кВт, спеціально розробленого для таких комплексів. Для спрощення конструкції конвеєрної системи подачі оброблюваної продукції в зону опромінення використовується випускний пристрій з поворотом пучка на 90 градусів інаступною конвертацією електронного пучка в гамма-випромінювання на вертикально розташованій мішені.Приводится описание ускорителя электронов ИЛУ-10 на энергию 5 МэВ мощностью 50 кВт, специально разработанного для таких комплексов. Для упрощения конструкции конвейерной системы подачи обрабатываемой продукции в зону облучения используется выпускное устройство с поворотом пучка на 90 градусов и последующей конвертацией электронного пучка в гамма-излучение на вертикально расположенной мишени

    ATLAS detector and physics performance: Technical Design Report, 1

    Get PDF

    Сравнительное исследование остеоинтеграции изготовленных с применением аддитивных технологий титановых и стальных имплантатов в большеберцовой кости кролика в условиях внешней фиксации

    Get PDF
    Relevance. The main goals of successful prosthesis remain ensuring the osseointegration and infectious safety of implants.The purpose of the study — the comparative analysis of osseointegration of titanium and steel additive manufactured implants in the rabbit tibia under additional fixation by Ilizarov apparatus.Materials and Methods. The study was performed on 20 chinchilla male rabbits. The animals of the first group (n = 8 ) were implanted a stainless steel product EOS PH1 (EOS, Germany), the animals of the second group (n = 12) — a titanium alloy Ti6Al4V product. The implant was additionally fixed by Ilizarov apparatus. The implants were processed with additive technology by selective laser fusion at the EOSINT M 280 installation (EOS, Germany). The survival and safety of the implants were assessed using clinical, histological, laboratory and statistical methods.Results. The implant fall due to chronic inflammation was found in 2 animals of group 1 and none in group 2. The formation of weakly mineralized bone tissue on the surface of the implant was noted in 3 weeks in all cases. The bone became more mineralized by the 12th week of the experiment. However, in group 2, the calcium content and Ca / P ratio of the newly formed bone tissue at the 3rd and 12th week after implantation were significantly higher than in the animals of group 1. This indicated the greater maturity of the bone tissue in animals of group 2 at all stages of the experiment. In group 1, the compact plate osteoporosis and calcium-phosphorus balance disturbance were greater.Conclusion. The results of the study indicate that the survival rate (osseointegration) and safety of the product made of the titanium alloy were higher compared with the stainless steel product.Актуальность. Основными задачами успешного протезирования остаются обеспечение остеоинтеграции и инфекционной безопасности имплантатов.Цель исследования — сравнительный анализ остеоинтеграции изготовленных с применением аддитивной технологии титановых и стальных имплантатов в большеберцовой кости кролика в условиях дополнительной фиксации биомеханической системы аппаратом Илизарова.Материал и методы. Исследование выполнено на 20 кроликах-самцах породы Шиншилла. Животным первой группы (n = 8) имплантировали изделие из нержавеющей стали марки EOS PH1 (EOS, Германия), животным второй группы (n = 12) — из титанового сплава марки Ti6Al4V. Имплантат дополнительно фиксировали аппаратом Илизарова. Имплантаты были изготовлены с применением аддитивной технологии методом селективного лазерного сплавления на установке EOSINT M 280 (EOS, Германия). Оценку приживаемости и безопасности применения имплантатов проводили с помощью клинического, гистологического, лабораторного и статистического методов исследования.Результаты. У животных группы 1 было зафиксировано два случая выпадения имплантата по причине хронического воспаления, в группе 2 таких случаев отмечено не было. Во всех экспериментах через 3 нед. отмечено формирование слабоминерализованной костной ткани на поверхности имплантата, которая становилась более минерализованной к 12-й нед. эксперимента. Однако содержание кальция и соотношение Са/Р в новообразованной костной ткани в группе 2 на 3-й и 12-й нед. после имплантации было статистически значимо выше показателей животных группы 1, что свидетельствовало о большей зрелости костной ткани у животных группы 2 на всех этапах эксперимента. В группе 1 отмечали большую выраженность остеопороза компактной пластинки и более существенное нарушение кальций-фосфорного баланса.Заключение. Результаты исследования позволяют заключить, что приживаемость (остеоинтеграция) и безопасность изделия, выполненного из титанового сплава, была выше по сравнению с изделием из нержавеющей стали

    Safety in Applying Binary Mixtures for Oil Production Stimulation

    No full text
    The article considers theoretically, on a qualitative level, the rates of filtration and decomposition of ammonium nitrate, depending on the time of heat release and on the rate of nitrate entry into the porous space of the reservoir near the perforations. It is assumed that field tests at different rates of nitrate solution injection into the well will yield quantitative data on filtration, heat transfer and kinetics of heat release in the reservoir. To estimate the temperature increase in the reservoir under the action of the binary mixture reaction (nitrate + oxidant), the temperature was calculated when the nitrate was decomposed in an aqueous solution (300 g of water per 1 kg of nitrate), taking into account the oxidation of a small fraction of oil in the reservoir near the well with oxygen released during the decomposition of nitrate
    corecore