1,337 research outputs found
Effects of feeding low fishmeal diets with increasing soybean meal levels on growth, gut histology and plasma biochemistry of sea bass
The aquaculture industry depends upon the development of sustainable protein sources to replace fishmeal (FM) in aquafeeds and the products derived from soybeans are some of the most studied plant feedstuffs. A key area of investigation for continuing to improve modern aquafeeds includes the evaluation of varying proportions and combinations of plant ingredients to identify mixtures that are more efficiently utilized by the fish. This study investigated the effects of increasing soybean meal (SBM) by replacing a mix of plant ingredients in low FM (20%) diets on growth, blood biochemistry profile and gut histology on European sea bass. Five isonitrogenous and isolipidic experimental diets were formulated: four diets containing increasing SBM levels (0, 10, 20 and 30%; 0SBM, 10SBM, 20SBM and 30SBM, respectively) with a low content of FM (20%) and one control diet (0% SBM; 35% FM). Diets containing SBM brought to comparable performance and protein utilization, while 0SBM had negative impact on feed conversion rate and protein utilization. Blood parameters suggested an optimal nutritional status under all feeding treatments, even though slightly decreased values were reported at increasing dietary SBM. Histology examination did not show any changes indicative of soy-induced enteritis. We can conclude that for European sea bass: (i) different blends of plant protein did not affect feed intake despite the 20% FM dietary level; (ii) the inclusion of SBM maintains optimal growth and feed utilization in low FM diets; (iii) blood biochemistry profile showed a good nutritional status under all feeding regimes; (iv) no evidence of soy-induced enteritis was reported in any group fed low FM diets. For formulation of practical diets in on-growing of European sea bass, SBM up to 30% can be successfully incorporated into feeds containing low FM inclusion
Red mark syndrome of trout (Oncorhynchus mykiss; Walbaum, 1792): Histopathological scoring and correlation with gross lesions
Red mark syndrome (RMS) is a skin disorder affecting rainbow trout (Oncorhynchus mykiss). The present work aimed to correlate the gross skin lesions affecting 46 fish sampled from farms surveyed for RMS with their microscopic features, identifying histological parameters that may be suggestive of disease progression. Skin lesions were grossly included in one of three categories (types I, II and III) according to the progressive degree of severity. Histological parameters and anti-proliferating cell nuclear antigen (PCNA) tissue immunoreactivity were semi-quantitatively assessed. In the dermis, PCNA-positive lymphocytes, fibroblasts and endothelial cells were indicative of active phlogosis. A significant increase in PCNA-immunoreactive lymphocytes, from gross type I to type III cases, was found only in the hypodermis. The histological parameters significantly associated with the gross lesion severity were progressive loss of the epithelium and scales, recruitment of inflammatory cells in the stratum compactum, loss of architecture of the stratum compactum, perivascular and perineural granulomatous inflammation and increase in lymphocyte infiltration of the muscular layer. In the type II and type III categories, inflammation in the hypodermis and muscle displayed a granulomatous pattern, reinforcing the hypothesis of an immunopathological mechanism. The morphological diagnosis of “deep chronic dermatitis associated to panniculitis and myositis, characterised by lympho-histiocytic and granulomatous reaction” is suggested
Search for strange quark matter and Q-balls with the SLIM experiment
We report on the search for Strange Quark Matter (SQM) and charged Q-balls
with the SLIM experiment at the Chacaltaya High Altitude Laboratory (5230 m
a.s.l.) from 2001 to 2005. The SLIM experiment was a 427 m array of
Nuclear Track Detectors (NTDs) arranged in modules of cm
area. SLIM NTDs were exposed to the cosmic radiation for 4.22 years after which
they were brought back to the Bologna Laboratory where they were etched and
analyzed. We estimate the properties and energy losses in matter of nuclearites
(large SQM nuggets), strangelets (small charged SQM nuggets) and Q-balls; and
discuss their detection with the SLIM experiment. The flux upper limits in the
CR of such downgoing particles are at the level of /cm/s/sr
(90% CL).Comment: 4 pages, 7 eps figures. Talk given at the 24th International
Conference on Nuclear Tracks in Solids, Bologna, Italy, 1-5 September 200
Bulk Etch Rate Measurements and Calibrations of Plastic Nuclear Track Detectors
New calibrations of CR39 and Makrofol nuclear track detectors have been
obtained using 158 A GeV Pb (82+) and In (49+) ions; a new method for the bulk
etch rate determination, using both cone height and base diameter measurements
was developed. The CR39 charge resolution based on the etch-pit base area
measurement is adequate to identify nuclear fragments in the interval 7 <=
Z/beta <= 49. For CR39 the detection threshold is at REL~50 MeV cm^2/g,
corresponding to a nuclear fragment with Z/beta~7. Base cone area distributions
for Makrofol foils exposed to Pb (82+) ions have shown for the first time all
peaks due to nuclear fragments with Z > 50; the distribution of the etched cone
heights shows well separated individual peaks for Z/beta = 78 - 83 (charge
pickup). The Makrofol detection threshold is at REL 2700 MeV cm^2/g,
corresponding to a nuclear fragment with Z/beta~50.Comment: 11 pages, 5 EPS figures. Submitted to Nucl. Instr. Meth.
WARNING: Physics Envy May Be Hazardous To Your Wealth!
The quantitative aspirations of economists and financial analysts have for
many years been based on the belief that it should be possible to build models
of economic systems - and financial markets in particular - that are as
predictive as those in physics. While this perspective has led to a number of
important breakthroughs in economics, "physics envy" has also created a false
sense of mathematical precision in some cases. We speculate on the origins of
physics envy, and then describe an alternate perspective of economic behavior
based on a new taxonomy of uncertainty. We illustrate the relevance of this
taxonomy with two concrete examples: the classical harmonic oscillator with
some new twists that make physics look more like economics, and a quantitative
equity market-neutral strategy. We conclude by offering a new interpretation of
tail events, proposing an "uncertainty checklist" with which our taxonomy can
be implemented, and considering the role that quants played in the current
financial crisis.Comment: v3 adds 2 reference
A narrow band neutrino beam with high precision flux measurements
The ENUBET facility is a proposed narrow band neutrino beam where lepton
production is monitored at single particle level in the instrumented decay
tunnel. This facility addresses simultaneously the two most important
challenges for the next generation of cross section experiments: a superior
control of the flux and flavor composition at source and a high level of
tunability and precision in the selection of the energy of the outcoming
neutrinos. We report here the latest results in the development and test of the
instrumentation for the decay tunnel. Special emphasis is given to irradiation
tests of the photo-sensors performed at INFN-LNL and CERN in 2017 and to the
first application of polysiloxane-based scintillators in high energy physics.Comment: Poster presented at NuPhys2017 (London, 20-22 December 2017). 5
pages, 2 figure
Prospect for Charge Current Neutrino Interactions Measurements at the CERN-PS
Tensions in several phenomenological models grew with experimental results on
neutrino/antineutrino oscillations at Short-Baseline (SBL) and with the recent,
carefully recomputed, antineutrino fluxes from nuclear reactors. At a
refurbished SBL CERN-PS facility an experiment aimed to address the open issues
has been proposed [1], based on the technology of imaging in ultra-pure
cryogenic Liquid Argon (LAr). Motivated by this scenario a detailed study of
the physics case was performed. We tackled specific physics models and we
optimized the neutrino beam through a full simulation. Experimental aspects not
fully covered by the LAr detection, i.e. the measurements of the lepton charge
on event-by-event basis and their energy over a wide range, were also
investigated. Indeed the muon leptons from Charged Current (CC) (anti-)neutrino
interactions play an important role in disentangling different phenomenological
scenarios provided their charge state is determined. Also, the study of muon
appearance/disappearance can benefit of the large statistics of CC muon events
from the primary neutrino beam. Results of our study are reported in detail in
this proposal. We aim to design, construct and install two Spectrometers at
"NEAR" and "FAR" sites of the SBL CERN-PS, compatible with the already proposed
LAr detectors. Profiting of the large mass of the two Spectrometers their
stand-alone performances have also been exploited.Comment: 70 pages, 38 figures. Proposal submitted to SPS-C, CER
A combined analysis technique for the search for fast magnetic monopoles with the MACRO detector
We describe a search method for fast moving ()
magnetic monopoles using simultaneously the scintillator, streamer tube and
track-etch subdetectors of the MACRO apparatus. The first two subdetectors are
used primarily for the identification of candidates while the track-etch one is
used as the final tool for their rejection or confirmation. Using this
technique, a first sample of more than two years of data has been analyzed
without any evidence of a magnetic monopole. We set a 90% CL upper limit to the
local monopole flux of in the
velocity range and for nucleon decay
catalysis cross section smaller than .Comment: 29 pages (12 figures). Accepted by Astroparticle Physic
The ENUBET Beamline
The ENUBET ERC project (2016-2021) is studying a narrow band neutrino beam
where lepton production can be monitored at single particle level in an
instrumented decay tunnel. This would allow to measure and
cross sections with a precision improved by about one order of
magnitude compared to present results. In this proceeding we describe a first
realistic design of the hadron beamline based on a dipole coupled to a pair of
quadrupole triplets along with the optimisation guidelines and the results of a
simulation based on G4beamline. A static focusing design, though less efficient
than a horn-based solution, results several times more efficient than
originally expected. It works with slow proton extractions reducing drastically
pile-up effects in the decay tunnel and it paves the way towards a time-tagged
neutrino beam. On the other hand a horn-based transferline would ensure higher
yields at the tunnel entrance. The first studies conducted at CERN to implement
the synchronization between a few ms proton extraction and a horn pulse of 2-10
ms are also described.Comment: Poster presented at NuPhys2018 (London 19-21 December 2018). 4 pages,
3 figure
- …