76 research outputs found

    Ultrasound Guided Placement of Single-Lumen Peripheral Intravenous Catheters in the Internal Jugular Vein

    Get PDF
    Introduction: The peripheral internal jugular (IJ), also called the “easy IJ,” is an alternative to peripheral venous access reserved for patients with difficult intravenous (IV) access. The procedure involves placing a single-lumen catheter in the IJ vein under ultrasound (US) guidance. As this technique is relatively new, the details regarding the ease of the procedure, how exactly it should be performed, and the safety of the procedure are uncertain. Our primary objective was to determine the success rate for peripheral IJ placement. Secondarily, we evaluated the time needed to complete the procedure and assessed for complications. Methods: This was a prospective, single-center study of US-guided peripheral IJ placement using a 2.5-inch, 18-gauge catheter on a convenience sample of patients with at least two unsuccessful attempts at peripheral IV placement by nursing staff. Peripheral IJ lines were placed by emergency medicine (EM) attending physicians and EM residents who had completed at least five IJ central lines. All physicians who placed lines for the study watched a 15-minute lecture about peripheral IJ technique. A research assistant monitored each line to assess for complications until the patient was discharged. Results: We successfully placed a peripheral IJ in 34 of 35 enrolled patients (97.1%). The median number of attempts required for successful cannulation was one (interquartile range (IQR): 1 to 2). The median time to successful line placement was 3 minutes and 6 seconds (IQR: 59 seconds to 4 minutes and 14 seconds). Two lines failed after placement, and one of the 34 successfully placed peripheral IJ lines (2.9%) had a complication – a local hematoma. There were, however, no arterial punctures or pneumothoraces. Although only eight of 34 lines were placed using sterile attire, there were no line infections. Conclusion: Our research adds to the growing body of evidence supporting US-guided peripheral internal jugular access as a safe and convenient procedure alternative for patients who have difficult IV access

    Regional development gaps in Argentina: A multidimensional approach to identify the location of policy priorities

    Get PDF
    Spatial inequalities within Latin American countries have historically attracted the interest ofacademics, policy-makers, and international agencies. This article aims to provide amultidimensional diagnosis of provincial development gaps in Argentina, in order to identifythe location of policy priorities. Therefore, we built a large database, which covers sevendevelopment dimensions, and applied multivariate analysis techniques to overcome someanalytical limitations of previous studies. Results show the stability of provincial developmentgaps between 2003 and 2013 and some heterogeneity within geographic regions. Instead,cluster analysis offers a better classification of Argentine provinces according to theirdevelopment gaps, which can help the government to prioritize the places wheredevelopment policies are strategic.Fil: Niembro, Andrés Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Patagonia Norte; Argentina. Universidad Nacional de Río Negro; ArgentinaFil: Sarmiento, Jesica Isabel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Patagonia Norte; Argentina. Universidad Nacional de Río Negro; Argentin

    The stigma turbine:A theoretical framework for conceptualizing and contextualizing marketplace stigma

    Get PDF
    Stigmas, or discredited personal attributes, emanate from social perceptions of physical characteristics, aspects of character, and “tribal” associations (e.g., race; Goffman 1963). Extant research emphasizes the perspective of the stigma target, with some scholars exploring how social institutions shape stigma. Yet the ways stakeholders within the socio-commercial sphere create, perpetuate, or resist stigma remain overlooked. We introduce and define marketplace stigma as the labeling, stereotyping, and devaluation by and of commercial stakeholders (consumers, companies and their employees, stockholders, institutions) and their offerings (products, services, experiences). We offer the Stigma Turbine (ST) as a unifying conceptual framework that locates marketplace stigma within the broader sociocultural context, and illuminates its relationship to forces that exacerbate or blunt stigma. In unpacking the ST, we reveal the critical role market stakeholders can play in (de)stigmatization, explore implications for marketing practice and public policy, and offer a research agenda to further our understanding of marketplace stigma and stakeholder welfare

    ATLAS detector and physics performance: Technical Design Report, 1

    Get PDF

    A library of model fragments on sustainability

    No full text

    A library of model fragments on sustainability

    No full text

    Mistakes and Pitfalls Associated with Two-Point Compression Ultrasound for Deep Vein Thrombosis

    No full text
    Two-point compression ultrasound is purportedly a simple and accurate means to diagnose proximal lower extremity deep vein thrombosis (DVT), but the pitfalls of this technique have not been fully elucidated. The objective of this study is to determine the accuracy of emergency medicine resident-performed two-point compression ultrasound, and to determine what technical errors are commonly made by novice ultrasonographers using this technique. Methods: This was a prospective diagnostic test assessment of a convenience sample of adult emergency department (ED) patients suspected of having a lower extremity DVT. After brief training on the technique, residents performed two-point compression ultrasounds on enrolled patients. Subsequently a radiology department ultrasound was performed and used as the gold standard. Residents were instructed to save videos of their ultrasounds for technical analysis. Results: Overall, 288 two-point compression ultrasound studies were performed. There were 28 cases that were deemed to be positive for DVT by radiology ultrasound. Among these 28, 16 were identified by the residents with two-point compression. Among the 260 cases deemed to be negative for DVT by radiology ultrasound, 10 were thought to be positive by the residents using two-point compression. This led to a sensitivity of 57.1% (95% CI [38.8-75.5]) and a specificity of 96.1% (95% CI [93.8-98.5]) for resident-performed two-point compression ultrasound. This corresponds to a positive predictive value of 61.5% (95% CI [42.8-80.2]) and a negative predictive value of 95.4% (95% CI [92.9-98.0]). The positive likelihood ratio is 14.9 (95% CI [7.5-29.5]) and the negative likelihood ratio is 0.45 (95% CI [0.29-0.68]). Video analysis revealed that in four cases the resident did not identify a DVT because the thrombus was isolated to the superior femoral vein (SFV), which is not evaluated by two-point compression. Moreover, the video analysis revealed that the most common mistake made by the residents was inadequate visualization of the popliteal vein. Conclusion: Two-point compression ultrasound does not identify isolated SFV thrombi, which reduces its sensitivity. Moreover, this technique may be more difficult than previously reported, in part because novice ultrasonographers have difficulty properly assessing the popliteal vein
    • 

    corecore