31 research outputs found

    Pericarditis Constrictiva in a 10-Year-Old Boy After Influenza A Virus Infection

    Get PDF
    Pericarditis constrictiva is caused by fibrotic degeneration of the pericardium and leads to impaired diastolic ventricular filling. The diagnosis of constrictive pericarditis in children remains challenging and often requires a multimodal approach. We present a case of a pericarditis constrictiva in a 10-year old boy after influenza A virus infection. Clinicians should be aware of this complication, especially in patients with symptoms of exertional dyspnea and congestive heart failur

    Reference ranges ("normal values") for cardiovascular magnetic resonance (CMR) in adults and children: 2020 update

    Get PDF
    Cardiovascular magnetic resonance (CMR) enables assessment and quantification of morphological and functional parameters of the heart, including chamber size and function, diameters of the aorta and pulmonary arteries, flow and myocardial relaxation times. Knowledge of reference ranges ("normal values") for quantitative CMR is crucial to interpretation of results and to distinguish normal from disease. Compared to the previous version of this review published in 2015, we present updated and expanded reference values for morphological and functional CMR parameters of the cardiovascular system based on the peer-reviewed literature and current CMR techniques. Further, databases and references for deep learning methods are included

    Feasibility of perfusion cardiovascular magnetic resonance in paediatric patients

    Get PDF
    AIMS: As coronary artery disease may also occur during childhood in some specific conditions, we sought to assess the feasibility and accuracy of perfusion cardiovascular magnetic resonance (CMR) in paediatric patients. METHODS AND RESULTS: First-pass perfusion CMR studies were performed under pharmacological stress with adenosine and by using a hybrid echo-planar pulse sequence with slice-selective saturation recovery preparation. Fifty-six perfusion CMR examinations were performed in 47 patients. The median age was 12 years (1 month-18 years), and weight 42.8 kg (2.6-82 kg). General anaesthesia was required in 18 patients. Mean examination time was 67 +/- 19 min. Diagnostic image quality was obtained in 54/56 examinations. In 23 cases the acquisition parameters were adapted to patient's size. Perfusion CMR was abnormal in 16 examinations. The perfusion defects affected the territory of the left anterior descending coronary artery in 11, of the right coronary artery in 3, and of the circumflex coronary artery in 2 cases. Compared to coronary angiography, perfusion CMR showed a sensitivity of 87% (CI 52-97%) and a specificity of 95% (CI 79-99%). CONCLUSION: In children, perfusion CMR is feasible and accurate. In very young children (less than 1 year old), diagnostic image quality may be limited

    Intra-observer and interobserver variability of biventricular function, volumes and mass in patients with congenital heart disease measured by CMR imaging

    Get PDF
    Cardiovascular magnetic resonance (CMR) imaging provides highly accurate measurements of biventricular volumes and mass and is frequently used in the follow-up of patients with acquired and congenital heart disease (CHD). Data on reproducibility are limited in patients with CHD, while measurements should be reproducible, since CMR imaging has a main contribution to decision making and timing of (re)interventions. The aim of this study was to assess intra-observer and interobserver variability of biventricular function, volumes and mass in a heterogeneous group of patients with CHD using CMR imaging. Thirty-five patients with CHD (7–62 years) were included in this study. A short axis set was acquired using a steady-state free precession pulse sequence. Intra-observer and interobserver variability was assessed for left ventricular (LV) and right ventricular (RV) volumes, function and mass by calculating the coefficient of variability. Intra-observer variability was between 2.9 and 6.8% and interobserver variability was between 3.9 and 10.2%. Overall, variations were smallest for biventricular end-diastolic volume and highest for biventricular end-systolic volume. Intra-observer and interobserver variability of biventricular parameters assessed by CMR imaging is good for a heterogeneous group of patients with CHD. CMR imaging is an accurate and reproducible method and should allow adequate assessment of changes in ventricular size and global ventricular function

    Indications for cardiovascular magnetic resonance in children with congenital and acquired heart disease: an expert consensus paper of the Imaging Working Group of the AEPC and the Cardiovascular Magnetic Resonance Section of the EACVI.

    Get PDF
    This article provides expert opinion on the use of cardiovascular magnetic resonance (CMR) in young patients with congenital heart disease (CHD) and in specific clinical situations. As peculiar challenges apply to imaging children, paediatric aspects are repeatedly discussed. The first section of the paper addresses settings and techniques, including the basic sequences used in paediatric CMR, safety, and sedation. In the second section, the indication, application, and clinical relevance of CMR in the most frequent CHD are discussed in detail. In the current era of multimodality imaging, the strengths of CMR are compared with other imaging modalities. At the end of each chapter, a brief summary with expert consensus key points is provided. The recommendations provided are strongly clinically oriented. The paper addresses not only imagers performing CMR, but also clinical cardiologists who want to know which information can be obtained by CMR and how to integrate it in clinical decision-making

    Review of journal of cardiovascular magnetic resonance 2010

    Get PDF
    There were 75 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2010, which is a 34% increase in the number of articles since 2009. The quality of the submissions continues to increase, and the editors were delighted with the recent announcement of the JCMR Impact Factor of 4.33 which showed a 90% increase since last year. Our acceptance rate is approximately 30%, but has been falling as the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. Last year for the first time, the Editors summarized the papers for the readership into broad areas of interest or theme, which we felt would be useful to practitioners of cardiovascular magnetic resonance (CMR) so that you could review areas of interest from the previous year in a single article in relation to each other and other recent JCMR articles [1]. This experiment proved very popular with a very high rate of downloading, and therefore we intend to continue this review annually. The papers are presented in themes and comparison is drawn with previously published JCMR papers to identify the continuity of thought and publication in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication

    Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease

    Full text link

    Anatomical reconstruction of proximal coronary artery stenosis in children

    Full text link
    OBJECTIVES Timing and method of surgical reconstruction for non-sclerotic proximal coronary artery stenosis, occurring de novo or post-coronary artery transfer, are evolving. We have pursued a technique of anatomical reconstruction of ostial and short segment proximal coronary artery stenosis and atresia in children, using patch plasty or interposition vein graft. Here, we discuss the medium- to long-term outcomes. METHODS Nine consecutive children undergoing 10 left main coronary artery reconstructions using autologous great saphenous vein patch (n = 4), autologous pericardium (n = 4), xenopericardium (n = 1) or great saphenous vein interposition graft (n = 1) were retrospectively analysed. Complementary wedge resection of the stenotic coronary ostium was performed in chronic cases. RESULTS The aetiology of coronary artery stenosis was post-arterial switch operation (n = 6), Takayasu's arteritis (n = 1), idiopathic left main coronary artery atresia (n = 1) and anomalous origin of the left coronary artery from the pulmonary artery (n = 1). The median age and weight at operation were 0.15 (range 0.01-13.1) years and 4.4 (range 3-13.1) kg, respectively. Survival was 100% at the medi follow-up of 12.6 (range 1-19.2) years. All patients showed normal left ventricular ejection fraction on transthoracic echocardiogram. In 1 patient, kinking of the proximal left circumflex artery resulted in non-significant obstruction. In all other cases, follow-up catheter angiography revealed unobstructed coronary arteries. Cardiac magnetic resonance tomography showed no significant perfusion deficit in any child. CONCLUSIONS Anatomical reconstruction of the proximal left coronary artery using autologous saphenous vein may allow optimal restoration of physiological coronary blood flow, keeping the option of future coronary bypass operation open

    Anatomical reconstruction of proximal coronary artery stenosis in children.

    No full text
    Timing and method of surgical reconstruction for non-sclerotic proximal coronary artery stenosis, occurring de novo or post-coronary artery transfer, are evolving. We have pursued a technique of anatomical reconstruction of ostial and short segment proximal coronary artery stenosis and atresia in children, using patch plasty or interposition vein graft. Here, we discuss the medium- to long-term outcomes. Nine consecutive children undergoing 10 left main coronary artery reconstructions using autologous great saphenous vein patch (n = 4), autologous pericardium (n = 4), xenopericardium (n = 1) or great saphenous vein interposition graft (n = 1) were retrospectively analysed. Complementary wedge resection of the stenotic coronary ostium was performed in chronic cases. The aetiology of coronary artery stenosis was post-arterial switch operation (n = 6), Takayasu's arteritis (n = 1), idiopathic left main coronary artery atresia (n = 1) and anomalous origin of the left coronary artery from the pulmonary artery (n = 1). The median age and weight at operation were 0.15 (range 0.01-13.1) years and 4.4 (range 3-13.1) kg, respectively. Survival was 100% at the medi follow-up of 12.6 (range 1-19.2) years. All patients showed normal left ventricular ejection fraction on transthoracic echocardiogram. In 1 patient, kinking of the proximal left circumflex artery resulted in non-significant obstruction. In all other cases, follow-up catheter angiography revealed unobstructed coronary arteries. Cardiac magnetic resonance tomography showed no significant perfusion deficit in any child. Anatomical reconstruction of the proximal left coronary artery using autologous saphenous vein may allow optimal restoration of physiological coronary blood flow, keeping the option of future coronary bypass operation open
    corecore