84 research outputs found
Optical Phonon Lasing in Semiconductor Double Quantum Dots
We propose optical phonon lasing for a double quantum dot (DQD) fabricated in
a semiconductor substrate. We show that the DQD is weakly coupled to only two
LO phonon modes that act as a natural cavity. The lasing occurs for pumping the
DQD via electronic tunneling at rates much higher than the phonon decay rate,
whereas an antibunching of phonon emission is observed in the opposite regime
of slow tunneling. Both effects disappear with an effective thermalization
induced by the Franck-Condon effect in a DQD fabricated in a carbon nanotube
with a strong electron-phonon coupling.Comment: 8 pages, 4 figure
Non-Equilibrium Edge Channel Spectroscopy in the Integer Quantum Hall Regime
Heat transport has large potentialities to unveil new physics in mesoscopic
systems. A striking illustration is the integer quantum Hall regime, where the
robustness of Hall currents limits information accessible from charge
transport. Consequently, the gapless edge excitations are incompletely
understood. The effective edge states theory describes them as prototypal
one-dimensional chiral fermions - a simple picture that explains a large body
of observations and calls for quantum information experiments with quantum
point contacts in the role of beam splitters. However, it is in ostensible
disagreement with the prevailing theoretical framework that predicts, in most
situations, additional gapless edge modes. Here, we present a setup which gives
access to the energy distribution, and consequently to the energy current, in
an edge channel brought out-of-equilibrium. This provides a stringent test of
whether the additional states capture part of the injected energy. Our results
show it is not the case and thereby demonstrate regarding energy transport, the
quantum optics analogy of quantum point contacts and beam splitters. Beyond the
quantum Hall regime, this novel spectroscopy technique opens a new window for
heat transport and out-of-equilibrium experiments.Comment: 13 pages including supplementary information, Nature Physics in prin
On Fano schemes of complete intersections
We provide enumerative formulas for the degrees of varieties parameterizing
hypersurfaces and complete intersections which contain pro-jective subspaces
and conics. Besides, we find all cases where the Fano scheme of the general
complete intersection is irregular of dimension at least 2, and for the Fano
surfaces we deduce formulas for their holomorphic Euler characteristic.Comment: Added lacking references, corrected acknowledgments, minor editorial
change
Electrons surfing on a sound wave as a platform for quantum optics with flying electrons
Electrons in a metal are indistinguishable particles that strongly interact
with other electrons and their environment. Isolating and detecting a single
flying electron after propagation to perform quantum optics like experiments at
the single electron level is therefore a challenging task. Up to date, only few
experiments have been performed in a high mobility two-dimensional electron gas
where the electron propagates almost ballistically. Flying electrons were
detected via the current generated by an ensemble of electrons and electron
correlations were encrypted in the current noise. Here we demonstrate the
experimental realisation of high efficiency single electron source and single
electron detector for a quantum medium where a single electron is propagating
isolated from the other electrons through a one-dimensional channel. The moving
potential is excited by a surface acoustic wave, which carries the single
electron along the 1D-channel at a speed of 3\mum/ns. When such a quantum
channel is placed between two quantum dots, a single electron can be
transported from one quantum dot to the other, which is several micrometres
apart, with a quantum efficiency of emission and detection of 96% and 92%,
respectively. Furthermore, the transfer of the electron can be triggered on a
timescale shorter than the coherence time T2* of GaAs spin qubits6. Our work
opens new avenues to study the teleportation of a single electron spin and the
distant interaction between spatially separated qubits in a condensed matter
system.Comment: Total 25 pages. 12 pages main text, 4 figures, 5 pages supplementary
materia
Structural and Electrical Characterization of Bi2Se3 Nanostructures Grown by Metalorganic Chemical Vapor Deposition
We characterize nanostructures of Bi2Se3 that are grown via metalorganic
chemical vapor deposition using the precursors diethyl selenium and trimethyl
bismuth. By adjusting growth parameters, we obtain either single-crystalline
ribbons up to 10 microns long or thin micron-sized platelets. Four-terminal
resistance measurements yield a sample resistivity of 4 mOhm-cm. We observe
weak anti-localization and extract a phase coherence length l_phi = 178 nm and
spin-orbit length l_so = 93 nm at T = 0.29 K. Our results are consistent with
previous measurements on exfoliated samples and samples grown via physical
vapor deposition.Comment: Related papers at http://pettagroup.princeton.ed
Morbidity and mortality after anaesthesia in early life: results of the European prospective multicentre observational study, neonate and children audit of anaesthesia practice in Europe (NECTARINE)
Background: Neonates and infants requiring anaesthesia are at risk of physiological instability and complications, but triggers for peri-anaesthetic interventions and associations with subsequent outcome are unknown. Methods: This prospective, observational study recruited patients up to 60 weeks' postmenstrual age undergoing anaesthesia for surgical or diagnostic procedures from 165 centres in 31 European countries between March 2016 and January 2017. The primary aim was to identify thresholds of pre-determined physiological variables that triggered a medical intervention. The secondary aims were to evaluate morbidities, mortality at 30 and 90 days, or both, and associations with critical events. Results: Infants (n=5609) born at mean (standard deviation [SD]) 36.2 (4.4) weeks postmenstrual age (35.7% preterm) underwent 6542 procedures within 63 (48) days of birth. Critical event(s) requiring intervention occurred in 35.2% of cases, mainly hypotension (>30% decrease in blood pressure) or reduced oxygenation (SpO2 <85%). Postmenstrual age influenced the incidence and thresholds for intervention. Risk of critical events was increased by prior neonatal medical conditions, congenital anomalies, or both (relative risk [RR]=1.16; 95% confidence interval [CI], 1.04–1.28) and in those requiring preoperative intensive support (RR=1.27; 95% CI, 1.15–1.41). Additional complications occurred in 16.3% of patients by 30 days, and overall 90-day mortality was 3.2% (95% CI, 2.7–3.7%). Co-occurrence of intraoperative hypotension, hypoxaemia, and anaemia was associated with increased risk of morbidity (RR=3.56; 95% CI, 1.64–7.71) and mortality (RR=19.80; 95% CI, 5.87–66.7). Conclusions: Variability in physiological thresholds that triggered an intervention, and the impact of poor tissue oxygenation on patient's outcome, highlight the need for more standardised perioperative management guidelines for neonates and infants. Clinical trial registration: NCT02350348
Difficult tracheal intubation in neonates and infants. NEonate and Children audiT of Anaesthesia pRactice IN Europe (NECTARINE): a prospective European multicentre observational study
Background: Neonates and infants are susceptible to hypoxaemia in the perioperative period. The aim of this study was to analyse interventions related to anaesthesia tracheal intubations in this European cohort and identify their clinical consequences. Methods: We performed a secondary analysis of tracheal intubations of the European multicentre observational trial (NEonate and Children audiT of Anaesthesia pRactice IN Europe [NECTARINE]) in neonates and small infants with difficult tracheal intubation. The primary endpoint was the incidence of difficult intubation and the related complications. The secondary endpoints were the risk factors for severe hypoxaemia attributed to difficult airway management, and 30 and 90 day outcomes. Results: Tracheal intubation was planned in 4683 procedures. Difficult tracheal intubation, defined as two failed attempts of direct laryngoscopy, occurred in 266 children (271 procedures) with an incidence (95% confidence interval [CI]) of 5.8% (95% CI, 5.1e6.5). Bradycardia occurred in 8% of the cases with difficult intubation, whereas a significant decrease in oxygen saturation (SpO2<90% for 60 s) was reported in 40%. No associated risk factors could be identified among comorbidities, surgical, or anaesthesia management. Using propensity scoring to adjust for confounders, difficult anaesthesia tracheal intubation did not lead to an increase in 30 and 90 day morbidity or mortality. Conclusions: The results of the present study demonstrate a high incidence of difficult tracheal intubation in children less than 60 weeks post-conceptual age commonly resulting in severe hypoxaemia. Reassuringly, the morbidity and mortality at 30 and 90 days was not increased by the occurrence of a difficult intubation event. Clinical trial registration: NCT02350348
Difficult tracheal intubation in neonates and infants. NEonate and Children audiT of Anaesthesia pRactice IN Europe (NECTARINE): a prospective European multicentre observational study
BACKGROUND: Neonates and infants are susceptible to hypoxaemia in the perioperative period. The aim of this study was to analyse interventions related to anaesthesia tracheal intubations in this European cohort and identify their clinical consequences. METHODS: We performed a secondary analysis of tracheal intubations of the European multicentre observational trial (NEonate and Children audiT of Anaesthesia pRactice IN Europe [NECTARINE]) in neonates and small infants with difficult tracheal intubation. The primary endpoint was the incidence of difficult intubation and the related complications. The secondary endpoints were the risk factors for severe hypoxaemia attributed to difficult airway management, and 30 and 90 day outcomes. RESULTS: Tracheal intubation was planned in 4683 procedures. Difficult tracheal intubation, defined as two failed attempts of direct laryngoscopy, occurred in 266 children (271 procedures) with an incidence (95% confidence interval [CI]) of 5.8% (95% CI, 5.1–6.5). Bradycardia occurred in 8% of the cases with difficult intubation, whereas a significant decrease in oxygen saturation (SpO2<90% for 60 s) was reported in 40%. No associated risk factors could be identified among co-morbidities, surgical, or anaesthesia management. Using propensity scoring to adjust for confounders, difficult anaesthesia tracheal intubation did not lead to an increase in 30 and 90 day morbidity or mortality. CONCLUSIONS: The results of the present study demonstrate a high incidence of difficult tracheal intubation in children less than 60 weeks post-conceptual age commonly resulting in severe hypoxaemia. Reassuringly, the morbidity and mortality at 30 and 90 days was not increased by the occurrence of a difficult intubation event
- …