Total Aortic Arch Replacement: Superior Ventriculo-Arterial Coupling with Decellularized Allografts Compared with Conventional Prostheses.
BACKGROUND: To date, no experimental or clinical study provides detailed analysis of vascular impedance changes after total aortic arch replacement. This study investigated ventriculoarterial coupling and vascular impedance after replacement of the aortic arch with conventional prostheses vs. decellularized allografts. METHODS: After preparing decellularized aortic arch allografts, their mechanical, histological and biochemical properties were evaluated and compared to native aortic arches and conventional prostheses in vitro. In open-chest dogs, total aortic arch replacement was performed with conventional prostheses and compared to decellularized allografts (n = 5/group). Aortic flow and pressure were recorded continuously, left ventricular pressure-volume relations were measured by using a pressure-conductance catheter. From the hemodynamic variables end-systolic elastance (Ees), arterial elastance (Ea) and ventriculoarterial coupling were calculated. Characteristic impedance (Z) was assessed by Fourier analysis. RESULTS: While Ees did not differ between the groups and over time (4.1+/-1.19 vs. 4.58+/-1.39 mmHg/mL and 3.21+/-0.97 vs. 3.96+/-1.16 mmHg/mL), Ea showed a higher increase in the prosthesis group (4.01+/-0.67 vs. 6.18+/-0.20 mmHg/mL, P<0.05) in comparison to decellularized allografts (5.03+/-0.35 vs. 5.99+/-1.09 mmHg/mL). This led to impaired ventriculoarterial coupling in the prosthesis group, while it remained unchanged in the allograft group (62.5+/-50.9 vs. 3.9+/-23.4%). Z showed a strong increasing tendency in the prosthesis group and it was markedly higher after replacement when compared to decellularized allografts (44.6+/-8.3dyn.sec.cm-5 vs. 32.4+/-2.0dyn.sec.cm-5, P<0.05). CONCLUSIONS: Total aortic arch replacement leads to contractility-afterload mismatch by means of increased impedance and invert ventriculoarterial coupling ratio after implantation of conventional prostheses. Implantation of decellularized allografts preserves vascular impedance thereby improving ventriculoarterial mechanoenergetics after aortic arch replacement
Measuring aesthetic emotions : a review of the literature and a new assessment tool
Aesthetic perception and judgement are not merely cognitive processes, but also involve feelings. Therefore, the empirical study of these experiences requires conceptualization and measurement of aesthetic emotions. Despite the long-standing interest in such emotions, we still lack an assessment tool to capture the broad range of emotions that occur in response to the perceived aesthetic appeal of stimuli. Elicitors of aesthetic emotions are not limited to the arts in the strict sense, but extend to design, built environments, and nature. In this article, we describe the development of a questionnaire that is applicable across many of these domains: the Aesthetic Emotions Scale (Aesthemos). Drawing on theoretical accounts of aesthetic emotions and an extensive review of extant measures of aesthetic emotions within specific domains such as music, literature, film, painting, advertisements, design, and architecture, we propose a framework for studying aesthetic emotions. The Aesthemos, which is based on this framework, contains 21 subscales with two items each, that are designed to assess the emotional signature of responses to stimuli’s perceived aesthetic appeal in a highly differentiated manner. These scales cover prototypical aesthetic emotions (e.g., the feeling of beauty, being moved, fascination, and awe), epistemic emotions (e.g., interest and insight), and emotions indicative of amusement (humor and joy). In addition, the Aesthemos subscales capture both the activating (energy and vitality) and the calming (relaxation) effects of aesthetic experiences, as well as negative emotions that may contribute to aesthetic displeasure (e.g., the feeling of ugliness, boredom, and confusion)