140 research outputs found

    High Bleeding Risk Patients Treated with Very Thin-Strut Biodegradable Polymer or Thin-Strut Durable Polymer Drug-Eluting Stents in the BIO-RESORT Trial

    Get PDF
    Purpose: Patients with high bleeding risk (HBR) who undergo percutaneous coronary intervention also have an increased risk of ischemic events and represent an overall high-risk population. The coating of durable polymer drug-eluting stents (DP-DES) may induce inflammation and delay arterial healing, which might be reduced by novel biodegradable polymer DES (BP-DES). We aimed to evaluate the safety and efficacy of treating HBR patients with very thin-strut BP-DES versus thin-strut DP-DES. Methods: Participants in BIO-RESORT (NCT01674803), an investigator-initiated multicenter, randomized all-comers trial, were treated with very thin-strut BP-DES (Synergy or Orsiro) or thin-strut DP-DES (Resolute Integrity). For the present analysis, patients were classified following HBR criteria based on previous trials. The primary endpoint was target vessel failure: a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization at 1 year. Results: Of all 3514 patients, 1009 (28.7%) had HBR. HBR patients were older (p < 0.001) and had more co-morbidities than non-HBR patients (p < 0.001). At 1-year follow-up, HBR patients had significantly higher rates of target vessel failure (6.7 vs. 4.2%, p = 0.003), cardiac death (1.9 vs. 0.4%, p < 0.001), and major bleeding (3.3 vs. 1.5%, p = 0.001). Of all 1009 HBR patients, 673 (66.7%) received BP-DES and 336 (33.3%) had DP-DES. The primary endpoint was met by 43/673 (6.5%) patients treated with BP-DES and 24/336 (7.3%) treated with DP-DES (HR 0.88 [95%CI 0.54–1.46], p = 0.63). There were no significant between-group differences in the most global patient-oriented clinical endpoint (9.7 vs. 10.5%, HR 0.92 [95%CI 0.61–1.39], p = 0.69) and other secondary endpoints. Conclusions: At 1-year follow-up, very thin-strut BP-DES showed similar safety and efficacy for treating HBR patients as thin-strut DP-DES

    Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents (BIONYX):Rationale and design of the randomized TWENTE IV multicenter trial

    Get PDF
    Aim: The aim was to compare in a noninferiority trial the efficacy and safety of 2 contemporary drug-eluting stents (DESs): a novel, durable polymer-coated stent versus an established bioabsorbable polymer-coated stent. Methods and results: The BIONYX trial (ClinicalTrials.gov-no.NCT02508714) is an investigator-initiated, prospective, randomized, patient- and assessor-blinded, international, multicenter study in all-comer patients with all types of clinical syndromes and lesions who require percutaneous coronary interventions with DES. Patients at 7 study sites in the Netherlands, Belgium, and Israel were randomly assigned (1:1, stratified for gender and diabetes mellitus) to treatment with the novel, zotarolimus-eluting, durable polymer-coated Resolute Onyx stent that has a radiopaque, thin-strut, CoreWire stent platform versus the sirolimus-eluting, bioresorbable polymer-coated Orsiro stent (reference device) that has a very thin-strut, cobalt-chromium stent backbone. The primary end point is the 1-year incidence of the composite clinical end point target vessel failure consisting of cardiac death, target vessel–related myocardial infarction, or clinically indicated target vessel revascularization. A power calculation, assuming a target vessel failure rate of 6.0% (noninferiority margin 2.5%), revealed that 2,470 study patients would give the study 80% power (α level 5%), allowing for up to 3% loss to follow-up. The first patient was enrolled on October 7, 2015; on December 23, 2016, the last patient entered the study. Conclusions: BIONYX is a large-scale, prospective, randomized, international, multicenter trial comparing a novel DES with durable coating versus a reference DES with biodegradable coating in all-comers. The study is the first randomized assessment of the Resolute Onyx stent, which is an often-used DES outside the United States

    Final 5-Year Report of the Randomized BIO-RESORT Trial Comparing 3 Contemporary Drug-Eluting Stents in All-Comers

    Get PDF
    BACKGROUND: In a previous trial, higher 5‐year mortality was observed following treatment with biodegradable polymer Orsiro sirolimus‐eluting stents (SES). We assessed 5‐year safety and efficacy of all‐comers as well as patients with diabetes treated with SES or Synergy everolimus‐eluting stents (EES) versus durable polymer Resolute Integrity zotarolimus‐eluting stents (ZES). METHODS AND RESULTS: The randomized BIO‐RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug‐Eluting Stents in an All Comers Population) trial enrolled 3514 all‐comer patients at 4 Dutch cardiac centers. Patients aged ≄18 years who required percutaneous coronary intervention were eligible. Participants were stratified for diabetes and randomized to treatment with SES, EES, or ZES (1:1:1). The main end point was target vessel failure (cardiac mortality, target vessel myocardial infarction, or target vessel revascularization). Five‐year follow‐up was available in 3183 of 3514 (90.6%) patients. The main end point target vessel failure occurred in 142 of 1169 (12.7%) patients treated with SES, 130 of 1172 (11.6%) treated with EES, versus 157 of 1173 (14.1%) treated with ZES (hazard ratio [HR], 0.89 [95% CI, 0.71–1.12], P (log‐rank)=0.31; and HR, 0.82 [95% CI, 0.65–1.04], P (log‐rank)=0.10, respectively). Individual components of target vessel failure showed no significant between‐stent difference. Very late definite stent thrombosis rates were low and similar (SES, 1.1%; EES, 0.6%; ZES, 0.9%). In patients with diabetes, target vessel failure did not differ significantly between stent‐groups (SES, 19.8%; EES, 19.2%; versus ZES, 21.1% [P (log‐rank)=0.69 and P (log‐rank)=0.63]). CONCLUSIONS: Orsiro SES, Synergy EES, and Resolute Integrity ZES showed similar 5‐year outcomes of safety and efficacy, including mortality. A prespecified stent comparison in patients with diabetes also revealed no significant differences in 5‐year clinical outcomes. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01674803

    Characteristics, Treatment Strategies and Outcome in Cardiogenic Shock Complicating Acute Myocardial Infarction:A Contemporary Dutch Cohort

    Get PDF
    Cardiogenic shock (CS) complicating acute myocardial infarction (AMI) is associated with high morbidity and mortality. Our study aimed to gain insights into patient characteristics, outcomes and treatment strategies in CS patients. Patients with CS who underwent percutaneous coronary intervention (PCI) between 2017 and 2021 were identified in a nationwide registry. Data on medical history, laboratory values, angiographic features and outcomes were retrospectively assessed. A total of 2328 patients with a mean age of 66 years and of whom 73% were male, were included. Mortality at 30 days was 39% for the entire cohort. Non-survivors presented with a lower mean blood pressure and increased heart rate, blood lactate and blood glucose levels (p-value for all &lt;0.001). Also, an increased prevalence of diabetes, multivessel coronary artery disease and a prior coronary event were found. Of all patients, 24% received mechanical circulatory support, of which the majority was via intra-aortic balloon pumps (IABPs). Furthermore, 79% of patients were treated with at least one vasoactive agent, and multivessel PCI was performed in 28%. In conclusion, a large set of hemodynamic, biochemical and patient-related characteristics was identified to be associated with mortality. Interestingly, multivessel PCI and IABPs were frequently applied despite a lack of evidence.</p

    Physiological aspects of the determination of comprehensive arterial inflows in the lower abdomen assessed by Doppler ultrasound

    Get PDF
    Non-invasive measurement of splanchnic hemodynamics has been utilized in the clinical setting for diagnosis of gastro-intestinal disease, and for determining reserve blood flow (BF) distribution. However, previous studies that measured BF in a "single vessel with small size volume", such as the superior mesenteric and coeliac arteries, were concerned solely with the target organ in the gastrointestinal area, and therefore evaluation of alterations in these single arterial BFs under various states was sometimes limited to "small blood volumes", even though there was a relatively large change in flow. BF in the lower abdomen (BFAb) is potentially a useful indicator of the influence of comprehensive BF redistribution in cardiovascular and hepato-gastrointestinal disease, in the postprandial period, and in relation to physical exercise. BFAb can be determined theoretically using Doppler ultrasound by subtracting BF in the bilateral proximal femoral arteries (FAs) from BF in the upper abdominal aorta (Ao) above the coeliac trunk. Prior to acceptance of this method of determining a true BFAb value, it is necessary to obtain validated normal physiological data that represent the hemodynamic relationship between the three arteries. In determining BFAb, relative reliability was acceptably high (range in intra-class correlation coefficient: 0.85-0.97) for three arterial hemodynamic parameters (blood velocity, vessel diameter, and BF) in three repeated measurements obtained over three different days. Bland-Altman analysis of the three repeated measurements revealed that day-to-day physiological variation (potentially including measurement error) was within the acceptable minimum range (95% of confidence interval), calculated as the difference in hemodynamics between two measurements. Mean BF (ml/min) was 2951 ± 767 in Ao, 316 ± 97 in left FA, 313 ± 83 in right FA, and 2323 ± 703 in BFAb, which is in agreement with a previous study that measured the sum of BF in the major part of the coeliac, mesenteric, and renal arteries. This review presents the methodological concept that underlies BFAb, and aspects of its day-to-day relative reliability in terms of the hemodynamics of the three target arteries, relationship with body surface area, respiratory effects, and potential clinical usefulness and application, in relation to data previously reported in original dedicated research

    Molecular diagnosis reveals genetic heterogeneity for the overlapping MKKS and BBS phenotypes

    Get PDF
    Hydrometrocolpos and polydactyly diagnosed in the prenatal period or early childhood may raise diagnostic dilemmas especially in distinguishing McKusick-Kaufman syndrome (MKKS) and the Bardet-Biedl syndrome (BBS). These two conditions can initially overlap. With time, the additional features of BBS appearing in childhood, such as retinitis pigmentosa, obesity, learning disabilities and progressive renal dysfunction allow clear differentiation between BBS and MKKS. Genotype overlap also exists, as mutations in the MKKS-BBS6 gene are found in both syndromes. We report 7 patients diagnosed in the neonatal period with hydrometrocolpos and polydactyly who carry mutations in various BBS genes (BBS6, BBS2, BBS10, BBS8 and BBS12), stressing the importance of wide BBS genotyping in patients with this clinical association for diagnosis, prognosis and genetic counselling
    • 

    corecore