15 research outputs found

    International multi-center study of iatrogenic retinal tears in pars plana vitrectomy

    Get PDF
    AIM: To study and compare the effect of different surgical settings on the development of iatrogenic retinal tears (IRT) in conventional (20-gauge) and microincisional vitrectomy. METHODS: An international retrospective comparative study of 394 patients who had simple vitrectomy at three tertiary centers. Surgeries were performed by four retina surgeons using different viewing systems. Two groups of eyes were compared: microincisional vitrectomy (327 eyes) and conventional (67 eyes) vitrectomy. An iatrogenic tear was defined as the occurrence of one or more peripheral retinal tears during surgery or at any visit in the first 6wk postoperatively. RESULTS: Mean age was 67+/-12y and 55% were female. Iatrogenic tears occurred in 11/394 (2.8%) of eyes. The rate of tears was similar among different surgeons and viewing systems (P=0.93 and P=0.76, respectively). Surgical indication, preexisting pseudophakia/aphakia, induction of posterior vitreous detachment (PVD) during surgery, and the use triamcinolone acetonide didn\u27t significantly affect the rate of tears (P \u3e 0.1 for all factors). A higher rate of tears was found in the conventional group compared to the microincisional group (respectively, 7.5%, 1.8%, P=0.02). CONCLUSION: The rate of IRT in vitrectomy is not significantly affected by surgical indication, preexisting PVD or pseudophakia, or use of triamcinolone or different viewing systems but is significantly higher in conventional vitrectomy. Microincisional platforms improve the safety of vitrectomy regardless of the viewing system used

    Fracture strength of endocrown maxillary restorations using different preparation designs and materials.

    Get PDF
    PURPOSE This study investigated the impact of preparation design and material types on fracture strength in maxillary premolars endocrowns after thermodynamic aging. MATERIALS AND METHODS Eighty two-rooted maxillary premolar crowns underwent endodontic treatment (N = 80, n = 10). The teeth were categorized into ten groups (4-mm deep with no intracanal extension lithium disilicate glass ceramic & multilayer zirconia endocrowns (LE0 & ZE0); 4-mm deep with 4-mm intracanal extension in one canal (LE1 & ZE1); 4-mm deep with 2-mm intracanal extensions in both canals (LE2 & ZE2); flat overlays with no endocore (LO & ZO); glass fiber reinforced post & core and crown (LC & ZC)). After cementation, all specimens were subjected to 1500 thermocycles and 1,200,000 chewing cycles with an axial occlusal load of 49 N. A static loading test was performed at a non-axial 45° loading using a universal testing machine and failure modes (Type I: restoration debonding; Type II: restoration fracture; Type III: restoration/tooth complex fracture above bone level; Type IV: restoration/tooth complex fracture below bone level) were evaluated using a stereoscope. Data were ananalzed using 2-way ANOVA and Tukey's tests (alpha = 0.05). RESULTS The endocrowns manufactured from multilayered zirconia and pressed lithium disilicate glass ceramic exhibited a fracture load ranging between 1334 ± 332 N and 756 ± 150 N, with ZC presenting the highest and LE2 the lowest values. The differences were not statistically significant (p > 0.05). CONCLUSION All endocrowns tested in this study performed similar considering the different designs and materials tested. The distribution of fracture modes did not differ significantly depending on the design of the restoration and the type of material used

    Protective Effects of Aryl Hydrocarbon Receptor Signaling in Celiac Disease Mucosa and in Poly I:C-Induced Small Intestinal Atrophy Mouse Model

    Get PDF
    Aryl hydrocarbon receptor (AhR), a transcription factor activated by a large number of natural and synthetic agents, modulates the activity of immune cells in the gut and represents an important link between the environment and immune-mediated pathologies. In this study, we investigated the role of AhR in celiac disease (CD), a gluten-driven enteropathy. AhR expression was evaluated in intestinal biopsies taken from patients with CD and controls by real-time polymerase chain reaction (PCR), immunohistochemistry and flow cytometry. AhR was also analyzed in ex vivo organ cultures of duodenal biopsies taken from inactive CD patients incubated in presence or absence of peptic-tryptic digest of gliadin. IFN-γ, TNF-α, granzyme B, and perforin expression was evaluated in anti-CD3/CD28-activated intestinal lamina propria mononuclear cells (LPMC) and intestinal intra-epithelial cells (IEL) of active CD patients cultured in the presence or absence of the AhR agonist 6-formylindolo(3, 2-b)carbazole (Ficz). Finally, the protective role of AhR was evaluated in a mouse model of poly I:C-driven small intestine damage. AhR RNA transcripts were reduced in active CD samples as compared to inactive CD and normal controls. Flow cytometry confirmed such results and showed a reduction of AhR in both IEL and LPMC of active CD patients. The addition of a peptic-tryptic digest of gliadin to ex vivo organ cultures of duodenal biopsies taken from inactive CD patients reduced AhR expression. Treatment of CD IEL and LPMC with Ficz reduced the levels of inflammatory cytokines, granzyme B and perforin. Mice injected with Ficz were protected against poly I:C-induced intestinal lesions. Our findings suggest that defective AhR-driven signals could contribute to amplify pathogenic responses in the gut of CD patients

    Clinical care pathway program versus open-access system: a study on appropriateness, quality, and efficiency in the delivery of colonoscopy in the colorectal cancer

    Get PDF
    Open-access colonoscopy (OAC), whereby the colonoscopy is performed without a prior office visit with a gastroenterologist, is affected by inappropriateness which leads to overprescription and reduced availability of the procedure in case of alarming symptoms. The clinical care pathway (CCP) is a healthcare management tool promoted by national health systems to organize work-up of various morbidities. Recently, we started a CCP dedicated to colorectal cancer (CRC), including a colonoscopy session for CRC diagnosis and prevention. We aimed to evaluate the appropriateness, the quality, and the efficiency in the delivery of colonoscopy with the open-access system and a CCP program in the CRC. Quality indicators for colonoscopy in subjects in the CCP were compared to referrals by general practitioners (OAC) or by non-gastroenterologist physicians (non-gastroenterologist physician colonoscopy, NGPC). Attendance rate to colonoscopy was greater in the CCP group and NGPC group than in the OAC group (99%, 99%, and 86%, respectively). Waiting time in the CCP group was shorter than in the OAC group (3.88 ± 2.27 vs. 32 ± 22.31 weeks, respectively). Appropriateness of colonoscopy prescription was better in the CCP group than in the OAC group (92 vs. 50%, respectively). OAC is affected by the lack of timeliness and low appropriateness of prescription. A CCP reduces the number of inappropriate colonoscopies, especially for post-polypectomy surveillance, and improves the delivery of colonoscopy in patients requiring a fast-track examination. The high rate of inappropriate OAC suggests that this modality of healthcare should be widely reviewed

    Success of 3-Unit Posterior All-Ceramic Inlay-Retained Fixed Dental Prostheses: A Narrative Literature Review

    Full text link
    PURPOSE OF REVIEW: This narrative review aimed to offer evidence on 3-unit all-ceramic posterior inlay-retained prostheses (IRFDPs) with an emphasis on material choice and design principles. Clinical trials and in vitro studies were identified using an electronic search in PubMed database. Overall, 16 in vitro publications and 8 clinical trials were included that reported on retainer designs, connector dimensions, and tooth preparation designs and detailed bonding techniques, evaluated replacement of posterior teeth, were clinical studies (follow-up ≥ 1 year), or addressed survival or failure rate, based on in vitro chewing simulator, fracture load, and in vivo technical or biological complications. RECENT FINDINGS: Material properties, restoration design, and adhesive technique showed a high impact on performance of IRFDPs. High-strength zirconia ceramics with intracoronal design bonded to enamel seem to perform well in the posterior region of the mouth. Furthermore, air abrasion at moderate pressure in combination with phosphate-containing resins provides durable bonding to zirconia ceramics. SUMMARY: Despite the advances in ceramic materials, there have been few scientific evidence to support the ideal preparation design that might improve clinical performance and restoration lifetime of 3-unit IRFDPs

    Fracture strength of endocrown maxillary restorations using different preparation designs and materials

    Get PDF
    PURPOSE: This study investigated the impact of preparation design and material types on fracture strength in maxillary premolars endocrowns after thermodynamic aging. MATERIALS AND METHODS: Eighty two-rooted maxillary premolar crowns underwent endodontic treatment (N = 80, n = 10). The teeth were categorized into ten groups (4-mm deep with no intracanal extension lithium disilicate glass ceramic & multilayer zirconia endocrowns (LE0 & ZE0); 4-mm deep with 4-mm intracanal extension in one canal (LE1 & ZE1); 4-mm deep with 2-mm intracanal extensions in both canals (LE2 & ZE2); flat overlays with no endocore (LO & ZO); glass fiber reinforced post & core and crown (LC & ZC)). After cementation, all specimens were subjected to 1500 thermocycles and 1,200,000 chewing cycles with an axial occlusal load of 49 N. A static loading test was performed at a non-axial 45° loading using a universal testing machine and failure modes (Type I: restoration debonding; Type II: restoration fracture; Type III: restoration/tooth complex fracture above bone level; Type IV: restoration/tooth complex fracture below bone level) were evaluated using a stereoscope. Data were ananalzed using 2-way ANOVA and Tukey's tests (alpha = 0.05). RESULTS: The endocrowns manufactured from multilayered zirconia and pressed lithium disilicate glass ceramic exhibited a fracture load ranging between 1334 ± 332 N and 756 ± 150 N, with ZC presenting the highest and LE2 the lowest values. The differences were not statistically significant (p > 0.05). CONCLUSION: All endocrowns tested in this study performed similar considering the different designs and materials tested. The distribution of fracture modes did not differ significantly depending on the design of the restoration and the type of material used

    The Effect of Visual Impairment and Its Severity on Vision-Related and Health-Related Quality of Life in Jordan: A Comparative Cross-Sectional Study

    Get PDF
    Purpose: To assess the effect of visual impairment (VI), its severity, and ocular diseases on vision-related and health-related quality of life (QoL) in Jordan. Patients and Methods: A comparative, cross-sectional, hospital-based study was conducted among a group of 278 patients with VI aged ≥ 18 years, and age and sex-matched control group of 278 individuals with no VI. An interviewer administered the National Eye Institute Visual Function Questionnaire (NEI VFQ-25) and the Medical Outcomes Study 12-Item Short Form Health Survey (SF-12) to all participants. Results: All the mean VFQ-25 subscales scores, physical component scale (PCS) and the mental component scale (MCS) of the SF-12 were significantly lower in patients with VI compared to controls with no VI. The VFQ-25 subscales (except general health and ocular pain), PCS, and MCS scores significantly decreased with more severity of VI. In the adjusted multivariate analysis, lower level of education (p=0.013), male sex (p=0.016), and the presence of cerebrovascular disease (p=0.019) were significantly associated with lower VFQ-25 composite scores in visually impaired patients compared to controls. Ocular disease duration of >5 years and progressive VI were significantly associated with lower VFQ-25 composite scores (p= 0.026 and p<0.001) respectively, in patients with VI. Glaucoma had a significantly larger reduction in mean scores of all the VFQ-25 subscales, and the PCS of the SF-12 compared to all other ocular diseases. Conclusion: Both VI and increasing severity of impairment were associated with reduced vision-related and health-related quality of life in adult Jordanians. Glaucoma patients and less educated people were particularly affected. Routine assessment of QoL in visually impaired patients and improving referral protocols to vision rehabilitation services is recommended to improve the QoL in those patients.This work was funded by the deanship of research, Jordan University of Science and Technology, Grant No: [20210196]

    Vitreous Levels of Vascular Endothelial Growth Factor and Platelet-Derived Growth Factor in Patients with Proliferative Diabetic Retinopathy: A Clinical Correlation

    No full text
    Background: The global epidemic status of diabetic retinopathy (DR) and its burden presents an ongoing challenge to health-care systems. It is of great interest to investigate potential prognostic biomarkers of DR. Such markers could aid in detecting early stages of DR, predicting DR progression and its response to therapeutics. Herein, we investigate the prognostic value of intravitreal concentrations of vascular endothelial growth factor (VEGF) and platelet-derived growth factor (PDGF) in a DR cohort. Materials and methods: Vitreous sample acquisition was conducted at King Abdullah University Hospital (KAUH) between December 2020 and June 2022. Samples were obtained from any patient scheduled to undergo a pars plana vitrectomy (PPV) for any indication. Included patients were categorized into a DR group or a corresponding non-diabetic (ND) control group. Demographics, clinicopathological variables, standardized laboratory tests results, and optical coherence tomography (OCT) data were obtained for each included individual. Intravitreal concentrations of VEGF and PDGF were assessed using commercial enzyme-linked immunosorbent assay (ELISA). Results: A total of 80 eyes from 80 patients (DR group: n = 42 and ND control group: n = 38) were included in the analysis. The vitreous VEGF levels were significantly higher in the DR group compared to the ND control group (DR group 5744.06 ± 761.5 pg/mL versus ND control group 817.94 ± 403.1 pg/mL, p = 0.0001). In addition, the vitreous PDGF levels were also significantly higher in the DR group than those in the ND control group (DR group 4031.51 ± 410.2 pg/mL versus ND control group 2691.46 ± 821.0 pg/mL, p = 0.001). Bassline differences between test groups and clinical factors impacting VEGF and PDGF concentrations were investigated as well. Multiple regression analysis indicated PDGF as the sole independent risk factor affecting best-corrected visual acuity (BCVA) at the last follow-up visit: the higher the PDGF vitreous levels, the worst the BCVA. Conclusions: Vitreous concentrations of VEGF and PDGF are correlated with DR severity and may exhibit a possible prognostic potential value in DR. Further clinical and experimental data are warranted to confirm the observed findings and to help incorporate them into daily practice

    Clinical efficacy of simulated vitreoretinal surgery to prepare surgeons for the upcoming intervention in the operating room

    No full text
    Purpose: To evaluate the efficacy of the virtual reality training simulator Eyesi to prepare surgeons for performing pars plana vitrectomies and its potential to predict the surgeons’ performance. Methods: In a preparation phase, four participating vitreoretinal surgeons performed repeated simulator training with predefined tasks. If a surgeon was assigned to perform a vitrectomy for the management of complex retinal detachment after a surgical break of at least 60 hours it was randomly decided whether a warmup training on the simulator was required (n = 9) or not (n = 12). Performance at the simulator was measured using the built-in scoring metrics. The surgical performance was determined by two blinded observers who analyzed the video-recorded interventions. One of them repeated the analysis to check for intra-observer consistency. The surgical performance of the interventions with and without simulator training was compared. In addition, for the surgeries with simulator training, the simulator performance was compared to the performance in the operating room. Results: Comparing each surgeon’s performance with and without warmup trainingshowed a significant effect of warmup training onto the final outcome in the operating room. For the surgeries that were preceeded by the warmup procedure, the performance at the simulator was compared with the operating room performance. We found that there is a significant relation. The governing factor of low scores in the simulator were iatrogenic retinal holes, bleedings and lens damage. Surgeons who caused minor damage in the simulation also performed well in the operating room. Conclusions: Despite the large variation of conditions, the effect of a warmup training as well as a relation between the performance at the simulator and in the operating room was found with statistical significance. Simulator training is able to serve as a warmup to increase the average performance
    corecore