70 research outputs found

    Effectiveness of the “Timed Up and Go” (TUG) and the Chair Test as Screening Tools for Geriatric Fall Risk Assessment in the ED

    Get PDF
    OBJECTIVE: We sought to evaluate the effectiveness of the Timed Up and Go (TUG) and the Chair test as screening tools in the Emergency Department (ED), stratified by sex. METHODS: This prospective cohort study was conducted at a Level 1 Trauma center. After consent, subjects performed the TUG and the Chair test. Subjects were contacted for phone follow-up and asked to self-report interim falling. RESULTS: Data from 192 subjects were analyzed. At baseline, 71.4% (n = 137) screened positive for increased falls risk based on the TUG evaluation, and 77.1% (n = 148) scored below average on the Chair test. There were no differences by patient sex. By the six-month evaluation 51 (26.6%) study participants reported at least one fall. Females reported a non-significant higher prevalence of falls compared to males (29.7% versus 22.2%, p = 0.24). TUG test had a sensitivity of 70.6% (95% CI: 56.2%-82.5%), a specificity of 28.4% (95% CI: 21.1%-36.6%), a positive predictive (PP) value 26.3% (95% CI: 19.1%-34.5%) and a negative predictive (NP) value of 72.7% (95% CI: 59.0%-83.9%). Similar results were observed with the Chair test. It had a sensitivity of 78.4% (95% CI: 64.7%-88.7%), a specificity of 23.4% (95% CI: 16.7%-31.3%), a PP value 27.0% (95% CI: 20.1%-34.9%) and a NP value of 75.0% (95% CI: 59.7%-86.8%). No significant differences were observed between sexes. CONCLUSIONS: There were no sex specific significant differences in TUG or Chair test screening performance. Neither test performed well as a screening tool for future falls in the elderly in the ED setting

    Validity and reliability of dermoscopic criteria used to differentiate nevi from melanoma aweb-based international dermoscopy society study

    Get PDF
    IMPORTANCE The comparative diagnostic performance of dermoscopic algorithms and their individual criteria are not well studied. OBJECTIVES To analyze the discriminatory power and reliability of dermoscopic criteria used in melanoma detection and compare the diagnostic accuracy of existing algorithms. DESIGN, SETTING, AND PARTICIPANTS Thiswas a retrospective, observational study of 477 lesions (119 melanomas [24.9%] and 358 nevi [75.1%]), which were divided into 12 image sets that consisted of 39 or 40 images per set. A link on the International Dermoscopy Society website from January 1, 2011, through December 31, 2011, directed participants to the study website. Data analysis was performed from June 1, 2013, through May 31, 2015. Participants included physicians, residents, and medical students, and there were no specialty-Type or experience-level restrictions. Participants were randomly assigned to evaluate 1 of the 12 image sets. MAIN OUTCOMES AND MEASURES Associations with melanoma and intraclass correlation coefficients (ICCs) were evaluated for the presence of dermoscopic criteria. Diagnostic accuracy measures were estimated for the following algorithms: The ABCD rule, the Menzies method, the 7-point checklist, the 3-point checklist, chaos and clues, and CASH (color, architecture, symmetry, and homogeneity). RESULTS A total of 240 participants registered, and 103 (42.9%) evaluated all images. The 110 participants (45.8%) who evaluated fewer than 20 lesions were excluded, resulting in data from 130 participants (54.2%), 121 (93.1%) of whom were regular dermoscopy users. Criteria associated with melanoma included marked architectural disorder (odds ratio [OR], 6.6; 95%CI, 5.6-7.8), pattern asymmetry (OR, 4.9; 95%CI, 4.1-5.8), nonorganized pattern (OR, 3.3; 95%CI, 2.9-3.7), border score of 6 (OR, 3.3; 95%CI, 2.5-4.3), and contour asymmetry (OR, 3.2; 95%CI, 2.7-3.7) (P < .001 for all). Most dermoscopic criteria had poor to fair interobserver agreement. Criteria that reached moderate levels of agreement included comma vessels (ICC, 0.44; 95%CI, 0.40-0.49), absence of vessels (ICC, 0.46; 95%CI, 0.42-0.51), dark brown color (ICC, 0.40; 95%CI, 0.35-0.44), and architectural disorder (ICC, 0.43; 95%CI, 0.39-0.48). The Menziesmethod had the highest sensitivity for melanoma diagnosis (95.1%) but the lowest specificity (24.8%) compared with any other method (P < .001). The ABCD rule had the highest specificity (59.4%). All methods had similar areas under the receiver operating characteristic curves. CONCLUSIONS AND RELEVANCE Important dermoscopic criteria for melanoma recognition were revalidated by participants with varied experience. Six algorithms tested had similar but modest levels of diagnostic accuracy, and the interobserver agreement of most individual criteria was poor

    Validity and Reliability of Dermoscopic Criteria Used to Differentiate Nevi From Melanoma: A Web-Based International Dermoscopy Society Study.

    Get PDF
    IMPORTANCE: The comparative diagnostic performance of dermoscopic algorithms and their individual criteria are not well studied. OBJECTIVES: To analyze the discriminatory power and reliability of dermoscopic criteria used in melanoma detection and compare the diagnostic accuracy of existing algorithms. DESIGN, SETTING, AND PARTICIPANTS: This was a retrospective, observational study of 477 lesions (119 melanomas [24.9%] and 358 nevi [75.1%]), which were divided into 12 image sets that consisted of 39 or 40 images per set. A link on the International Dermoscopy Society website from January 1, 2011, through December 31, 2011, directed participants to the study website. Data analysis was performed from June 1, 2013, through May 31, 2015. Participants included physicians, residents, and medical students, and there were no specialty-type or experience-level restrictions. Participants were randomly assigned to evaluate 1 of the 12 image sets. MAIN OUTCOMES AND MEASURES: Associations with melanoma and intraclass correlation coefficients (ICCs) were evaluated for the presence of dermoscopic criteria. Diagnostic accuracy measures were estimated for the following algorithms: the ABCD rule, the Menzies method, the 7-point checklist, the 3-point checklist, chaos and clues, and CASH (color, architecture, symmetry, and homogeneity). RESULTS: A total of 240 participants registered, and 103 (42.9%) evaluated all images. The 110 participants (45.8%) who evaluated fewer than 20 lesions were excluded, resulting in data from 130 participants (54.2%), 121 (93.1%) of whom were regular dermoscopy users. Criteria associated with melanoma included marked architectural disorder (odds ratio [OR], 6.6; 95% CI, 5.6-7.8), pattern asymmetry (OR, 4.9; 95% CI, 4.1-5.8), nonorganized pattern (OR, 3.3; 95% CI, 2.9-3.7), border score of 6 (OR, 3.3; 95% CI, 2.5-4.3), and contour asymmetry (OR, 3.2; 95% CI, 2.7-3.7) (P < .001 for all). Most dermoscopic criteria had poor to fair interobserver agreement. Criteria that reached moderate levels of agreement included comma vessels (ICC, 0.44; 95% CI, 0.40-0.49), absence of vessels (ICC, 0.46; 95% CI, 0.42-0.51), dark brown color (ICC, 0.40; 95% CI, 0.35-0.44), and architectural disorder (ICC, 0.43; 95% CI, 0.39-0.48). The Menzies method had the highest sensitivity for melanoma diagnosis (95.1%) but the lowest specificity (24.8%) compared with any other method (P < .001). The ABCD rule had the highest specificity (59.4%). All methods had similar areas under the receiver operating characteristic curves. CONCLUSIONS AND RELEVANCE: Important dermoscopic criteria for melanoma recognition were revalidated by participants with varied experience. Six algorithms tested had similar but modest levels of diagnostic accuracy, and the interobserver agreement of most individual criteria was poor

    Comparison of Airway Intubation Devices When Using a Biohazard Suit: A Feasibility Study

    Get PDF
    OBJECTIVES: We set out to compare emergency medicine residents\u27 intubating times and success rates for direct laryngoscopy (DL), GlideScope-assisted intubation (GS), and the Supraglottic Airway Laryngopharyngeal Tube (SALT) airway with and without biohazard gear. METHODS: Each resident passed through 2 sets of 3 testing stations (DL, GS, SALT) in succession, intubating Laerdal mannequin heads with the 3 modalities after randomization to start with or without biohazard gear. RESULTS: Thirty-seven residents participated, and 27 were male (73%); 14 (37.8%) had prior experience intubating in biohazard suits. There was a statistically significant difference in those who had prior intubation experience between DL (37, 100%), GS (32, 86.5%), and SALT (12, 32.4%) (P \u3c .001) and in median time to intubation (48 seconds, no suit; 57 seconds, with suits) (P = .03). There was no statistically significant difference between the overall times to intubate for the 3 devices. First-pass success was highest for DL (91.2%, no suit; 83.7%, suit) followed by GS (89%, no suit; 78.3%, suit) and SALT (51%, no suit; 67.6%, suit). CONCLUSION: A minority of participants had prior experience intubating in biohazard suits. Use of biohazard suits extends time to successful intubation. There was no difference in time to intubation for the 3 devices, but first-pass success was highest for DL (with or without biohazard gear)

    Nevi in Children and Adults: Dermoscopic Patterns and the Development of New Nevi

    No full text
    Nevi are the strongest risk factor for melanoma, as the risk of melanoma rises in individuals with a high number of melanocytic nevi. Yet, the melanocytic nevi in an individual change throughout one’s lifetime. By definition, acquired nevi appear after birth; the number of acquired nevi increases in the early decades, followed by a decrease in later life. According to the prevailing wisdom, individuals acquire nevi which then senesce and ultimately disappear; however, the process of nevogenesis may, in fact, be more dynamic. Although dermoscopy can provide greater insights into nevogenesis, there are relatively few studies that closely follow the development of nevi over an individual’s lifetime. Cross-sectional and longitudinal studies regarding the dermoscopic pattern of nevi and the number of melanocytic nevi in both children and adults will be discussed below

    Total Body Skin Examination Practices: A Survey Study Amongst Dermatologists at High-Risk Skin Cancer Clinics

    Get PDF
    Background/Objectives Although total body skin examination (TBSE) is the primary screening mechanism for melanoma, there is no consensus on which anatomic sites a screening TBSE should include. We sought to establish which anatomic sites are examined during routine (>90%) TBSEs of patients at high risk for skin cancer. Methods A Google survey was emailed to 173 international dermatologist skin cancer specialists. Results More than 75% of participants reported routinely examining the scalp, ears, face and neck, trunk, breasts, inframammary areas, axillae, extremities, palms and soles, nails, interdigital spaces, and buttocks. The least frequently inspected anatomic sites included genitalia, with male genitalia more frequently examined than female (penis n = 39; 52%; labia majora n = 21; 28%; P = 0.003), the perianal region (n = 26; 34.7%), and the ocular conjunctiva and oral mucosa (n = 35; 46.7%). Participants cited not screening these areas because of perceived patient discomfort, low prevalence of malignancy, and the expectation that other specialists examine the area. Conclusions The role of routine surveillance of neglected anatomic sites is unclear and warrants further discussion weighing potential mortality benefit against the incidence of melanoma in obscure sites, morbidity of intervention in sensitive sites, cost-effectiveness, and potential for patient discomfort
    corecore