19 research outputs found

    Detection and Differentiation of Intraretinal Hemorrhage in Spectral Domain Optical Coherence Tomography.

    No full text
    PURPOSE The purpose of this study was to classify and detect intraretinal hemorrhage (IRH) in spectral domain optical coherence tomography (SD-OCT). METHODS Initially the presentation of IRH in BRVO-patients in SD-OCT was described by one reader comparing color-fundus (CF) and SD-OCT using dedicated software. Based on these established characteristics, the presence and the severity of IRH in SD-OCT and CF were assessed by two other masked readers and the inter-device and the inter-observer agreement were evaluated. Further the area of IRH was compared. RESULTS About 895 single B-scans of 24 eyes were analyzed. About 61% of SD-OCT scans and 46% of the CF-images were graded for the presence of IRH (concordance: 73%, inter-device agreement: k = 0.5). However, subdivided into previously established severity levels of dense (CF: 21.3% versus SD-OCT: 34.7%, k = 0.2), flame-like (CF: 15.5% versus SD-OCT: 45.5%, k = 0.3), and dot-like (CF: 32% versus SD-OCT: 24.4%, k = 0.2) IRH, the inter-device agreement was weak. The inter-observer agreement was strong with k = 0.9 for SD-OCT and k = 0.8 for CF. The mean area of IRH detected on SD-OCT was significantly greater than on CF (SD-OCT: 11.5 ± 4.3 mm(2) versus CF: 8.1 ± 5.5 mm(2), p = 0.008). CONCLUSIONS IRH seems to be detectable on SD-OCT; however, the previously established severity grading agreed weakly with that assessed by CF

    Multimodal Imaging of Cotton Wool Spots in Branch Retinal Vein Occlusion.

    Get PDF
    PURPOSE: To describe and follow cotton wool spots (CWS) in branch retinal vein occlusion (BRVO) using multimodal imaging. METHODS: In this prospective cohort study including 24 patients with new-onset BRVO, CWS were described and analyzed in color fundus photography (CF), spectral domain optical coherence tomography (SD-OCT), infrared (IR) and fluorescein angiography (FA) every 3 months for 3 years. The CWS area on SD-OCT and CF was evaluated using OCT-Tool-Kit software: CWS were marked in each single OCT B-scan and the software calculated the area by interpolation. RESULTS: 29 central CWS lesions were found. 100% of these CWS were visible on SD-OCT, 100% on FA and 86.2% on IR imaging, but only 65.5% on CF imaging. CWS were visible for 12.4 ± 7.5 months on SD-OCT, for 4.4 ± 3 months and 4.3 ± 3.4 months on CF and on IR, respectively, and for 17.5 ± 7.1 months on FA. The evaluated CWS area on SD-OCT was larger than on CF (0.26 ± 0.17 mm(2) vs. 0.13 ± 0.1 mm(2), p < 0.0001). The CWS area on SD-OCT and surrounding pathology such as intraretinal cysts, avascular zones and intraretinal hemorrhage were predictive for how long CWS remained visible (r(2) = 0.497, p < 0.002). CONCLUSIONS: The lifetime and presentation of CWS in BRVO seem comparable to other diseases. SD-OCT shows a higher sensitivity for detecting CWS compared to CF. The duration of visibility of CWS varies among different image modalities and depends on the surrounding pathology and the CWS size

    Intravitreal Dexamethasone Implant (Ozurdex ®

    No full text
    Purpose: To evaluate the efficacy and safety of intravitreal 0.7-mg dexamethasone implant (DEX-I) (Ozurdex (R)) in the treatment of extensive exudative retinal detachment (RD) associated with uveal melanoma treated using proton beam therapy (PBT). Methods: Data from 10 patients with exudative RD after PBT treated with intravitreal injection of 0.7-mg DEX-I were reviewed retrospectively. The main outcome measures were resolution of exudative RD, visual acuity, and safety profile. Results: Mean age was 55.6 years (range 34-85). Mean time between PBT and DEX-I was 12.4 months (range 3-25). Mean follow-up was 9.9 months (range 4-15). Intravitreal Ozurdex (R) reduced exudative RD in 7 cases (70%) on average 3.1 months after injection with complete resolution of RD in 6 of these (60%). For half of the patients, their level of vision remained stable; the other half experienced a deterioration in visual acuity at the end of follow-up. No adverse effects were observed. Conclusions: In this small case series, treatment with intravitreal DEX-I reduced exudative RD in the majority of cases and had an acceptable safety profile
    corecore