58 research outputs found

    Ultrasound in Space Medicine

    Get PDF
    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed

    Diagnostic Imaging in the Medical Support of the Future Missions to the Moon

    Get PDF
    This viewgraph presentation is a course that reviews the diagnostic imaging techniques available for medical support on the future moon missions. The educational objectives of the course are to: 1) Update the audience on the curreultrasound imaging in space flight; 2) Discuss the unique aspects of conducting ultrasound imaging on ISS, interplanetary transit, ultrasound imaging on ISS, interplanetary transit, and lunar surface operations; and 3) Review preliminary data obtained in simulations of medical imaging in lunar surface operations

    Dose-Response Evaluation of Braslet-M Occlusion Cuffs

    Get PDF
    Introduction: Braslet-M is a set of special elasticized thigh cuffs used by the Russian space agency to reduce the effects of the head-ward fluid shift during early adaptation to microgravity by sequestering fluid in the lower extremities. Currently, no imaging modalities are used in the calibration of the device, and the pressure required to produce a predictable physiological response is unknown. This investigation intends to relate the pressure exerted by the cuffs to the extent of fluid redistribution and commensurate physiological effects. Materials and Methods: Ten healthy subjects with standardized fluid intake participated in the study. Data collection included femoral and internal jugular vein imaging in two orthogonal planes, pulsed Doppler of cervical and femoral vessels and middle cerebral artery, optic nerve imaging, and echocardiography. Braslet-M cuff pressure was monitored at the skin interface using pre-calibrated pressure sensors. Using 6 and 30 head-down tilt in two separate sessions, the effect of Braslet-M was assessed while incrementally tightening the cuffs. Cuffs were then simultaneously released to document the resulting hemodynamic change. Results: Preliminary analysis shows correlation between physical pressure exerted by the Braslet-M device and several parameters such as jugular and femoral vein cross-sections, resistivity of the lower extremity vascular bed, and others. A number of parameters reflect blood redistribution and will be used to determine the therapeutic range of the device and to prevent unsafe application. Conclusion: Braslet-M exerts a physical effect that can be measured and correlated with many changes in central and peripheral hemodynamics. Analysis of the full data set will be required to make definitive recommendations regarding the range of safe therapeutic application. Objective data and subjective responses suggest that a safer and equally effective use of Braslet can be achieved when compared with the current non-imaging calibration techniques

    Evaluating Trauma Sonography for Operational Use in the Microgravity Environment

    Get PDF
    Sonography is the only medical imaging modality aboard the ISS, and is likely to remain the leading imaging modality in future human space flight programs. While trauma sonography (TS) has been well recognized for terrestrial trauma settings, the technique had to be evaluated for suitability in space flight prior to adopting it as an operational capability. The authors found the following four-phased evaluative approach applicable to this task: 1) identifying standard or novel terrestrial techniques for potential use in space medicine; 2) developing and testing these techniques with suggested modifications on the ground (1g) either in clinical settings or in animal models, as appropriate; 3) evaluating and refining the techniques in parabolic flight (0g); and 4) validating and implementing for clinical use in space. In Phase I of the TS project, expert opinion and literature review suggested TS to be a potential screening tool for trauma in space. In Phase II, animal models were developed and tested in ground studies, and clinical studies were carried out in collaborating trauma centers. In Phase III, animal models were flight-tested in the NASA KC-135 Reduced Gravity Laboratory. Preliminary results of the first three phases demonstrated potential clinical utility of TS in microgravity. Phase IV studies have begun to address crew training issues, on-board imaging protocols, and data transfer procedures necessary to offer the modified TS technique for space use

    Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using Ultrasound and Braslet-M Occlusion Cuffs

    Get PDF
    The objective of this joint U.S. - Russian project was the development and validation of an in-flight methodology to assess a number of cardiac and vascular parameters associated with circulating volume and its manipulation in long-duration space flight. Responses to modified Valsalva and Mueller maneuvers were measured by cardiac and vascular ultrasound (US) before, during, and after temporary volume reduction by means of Braslet-M thigh occlusion cuffs (Russia). Materials and Methods: The study protocol was conducted in 14 sessions on 9 ISS crewmembers, with an average exposure to microgravity of 122 days. Baseline cardiovascular measurements were taken by echocardiography in multiple modes (including tissue Doppler of both ventricles) and femoral and jugular vein imaging on the International Space Station (ISS). The Braslet devices were then applied and measurements were repeated after >10 minutes. The cuffs were then released and the hemodynamic recovery process was monitored. Modified Valsalva and Mueller maneuvers were used throughout the protocol. All US data were acquired by the HDI-5000 ultrasound system aboard the ISS (ATL/Philips, USA) during remotely guided sessions. The study protocol, including the use of Braslet-M for this purpose, was approved by the ISS Human Research Multilateral Review Board (HRMRB). Results: The effects of fluid sequestration on a number of echocardiographic and vascular parameters were readily detectable by in-flight US, as were responses to respiratory maneuvers. The overall volume status assessment methodology appears to be valid and practical, with a decrease in left heart lateral E (tissue Doppler) as one of the most reliable measures. Increase in the femoral vein cross-sectional areas was consistently observed with Braslet application. Other significant differences and trends within the extensive cardiovascular data were also observed. (Decreased - RV and LV preload indices, Cardiac Output, LV E all maneuvers, LV Stroke Volume). Conclusions: This Study: 1) Addressed specific aspects of operational space medicine and space physiology, including assessment of circulating volume disturbances 2) Expanded the applications of diagnostic ultrasound imaging and Doppler techniques in microgravity. 3) Used respiratory maneuvers against the background of acute circulating volume manipulations which appear to enhance our ability to noninvasively detect volume-dependency in a number of cardiac and vascular parameters. 4) Determined that Tei index is not clinically changed therefore contractility not altered in the face of reduced preload. 5) Determined that increased Femoral Vein Area indicating blood being sequestered in lower extremities correlates with reduced preload and cardiac output. 6) That Braslet may be the only feasible means of acutely treating high pressure pulmonary edema in reduced gravity environments

    Right Ventricular Tissue Doppler in Space Flight

    Get PDF
    Tissue Doppler (TD) registers movement of a given sample of cardiac tissue throughout the cardiac cycle. TD spectra of the right ventricle (RV) were obtained from a long-duration ISS crewmember as a portion of an ongoing experiment ("Braslet" test objective). To our knowledge, this is the first report of RV TD conducted in space flight, and the data represent reproducibility and fidelity of this application in space and serve as the first "space normal" data set. Methods RV TD was performed by astronaut scientists remotely guided by an ultrasound expert from Mission Control Center, Houston, TX. In four of the subjects, RV TD was acquired from the free wall near the tricuspid annulus in two separate sessions 4 to 7 days apart. A fifth subject had only one session. All digital DICOM frames were exported for off-line analysis. Systolic (S ), early diastolic (E ) and late diastolic (A ) velocities were measured. RV Tei-index was calculated using diastolic and systolic time intervals as a combined measure of myocardial performance. Results and Discussion The mean values from the first 4 subjects (8 sessions) were used as the on-orbit reference data, and subject 5 was considered as a hypothetical patient for comparison (see Table). The greatest difference was in the early diastolic A (31 %) yet the standard deviation (a) for A amongst the reference subjects was 2.25 (mean = 16.02). Of interest is the Tei index, a simple and feasible indicator of overall ventricular function; it was similar amongst all the subjects. The late diastolic A seems to compensate for the variance in E . Normal Tei index for the RV is < 0.3, yet our data show all but one subject consistently above this level, notwithstanding their nominal responses to daily exercise in microgravity. These data remind us that the physiology of RV preload in altered gravity environments is still not completely understood

    Cardiac and Vascular Responses to Thigh Cuffs and Respiratory Maneuvers on Crewmembers of the International Space Station

    Get PDF
    The transition to microgravity eliminates the hydrostatic gradients in the vascular system. The resulting fluid redistribution commonly manifests as facial edema, engorgement of the external neck veins, and a decrease in leg diameter. This experiment examined the responses to modified Valsalva and Mueller maneuvers measured by cardiac and vascular ultrasound (ECHO) in a baseline steady state and during preload reduction introduced with thigh occlusion cuffs used as a counter-measure device (Braslet cuffs) measured by cardiac and vascular ultrasound examinations. Methods: Nine International Space Station crewmember subjects (Expeditions 16 - 20) were examined in 15 experiment sessions 101 +/- 46.days after launch (mean +/- SD; 33 - 185). Twenty Seven cardiac and vascular parameters were obtained with/without respiratory maneuvers before and after tightening of the Braslet cuffs. Results: Non-physicians performed diagnostic-quality cardiac and vascular ultrasound examinations using remote guidance. Three of 27 combinations of maneuvers and Braslet or Braslet alone were identified as being significant changed when compared to baseline. Eleven of 81 differences between combinations of Mueller, Valsalva or baseline were significant and related to cardiac preload reduction or increase in lower extremity venous volume. Conclusions: Acute application of Braslet occlusion cuffs causes lower extremity fluid sequestration and exerts commensurate measurable effects on cardiac performance in microgravity. Ultrasound techniques to measure the hemodynamic effects of thigh cuffs in combination with respiratory maneuvers may serve as an invaluable tool in determining the volume status of the cardiac patient at the 'microgravity bedside'

    Rapid Diagnosis of an Ulnar Fracture with Portable Hand-Held Ultrasound

    Get PDF
    Orthopedic fractures are a common injury in operational activities, injuries that often occur in isolated or hostile environments. Clinical ultrasound devices have become more user friendly and lighter allowing them to be easily transported with forward medical teams. The bone-soft tissue interface has a very large acoustic impedance, with a high reflectance that can be used to visualize breaks in contour including fractures. Herein reported is a case of an ulnar fracture that was quickly visualized in the early phase of a multi-system trauma resuscitation with a hand-held ultrasound device. The implications for operational medicine are discussed

    On-Orbit Prospective Echocardiography on International Space Station

    Get PDF
    A number of echocardiographic research projects and experiments have been flown on almost every space vehicle since 1970, but validation of standard methods and the determination of Space Normal cardiac function has not been reported to date. Advanced Diagnostics in Microgravity (ADUM) -remote guided echocardiographic technique provides a novel and effective approach to on-board assessment of cardiac physiology and structure using a just-in-time training algorithm and real-time remote guidance aboard the International Space Station (ISS). The validation of remotely guided echocardiographic techniques provides the procedures and protocols to perform scientific and clinical echocardiography on the ISS and the Moon. The objectives of this study were: 1.To confirm the ability of non-physician astronaut/cosmonaut crewmembers to perform clinically relevant remotely guided echocardiography using the Human Research Facility on board the ISS. 2.To compare the preflight, postflight and in-flight echocardiographic parameters commonly used in clinical medicine

    Ultrasound Fracture Diagnosis in Space

    Get PDF
    Introduction: This ground-based investigation accumulated high-level clinical evidence on the sensitivity and specificity of point of care ultrasound performed by expert and novice users for the rapid diagnosis of musculoskeletal (MSK) injuries. We developed preliminary educational methodologies to provide just-in-time training of novice users by creating multi-media training tools and imaging procedures for non expert operators and evaluated the sensitivity and specificity of non-expert performed musculoskeletal ultrasound to diagnose acute injuries in a Level 1 Trauma Center. Methods: Patients with potential MSK injuries were identified in the emergency room. A focused MSK ultrasound was performed by expert operators and compared to standard radiographs. A repeat examination was performed by non-expert operators who received a short, just-in-time multimedia education aid. The sensitivity and specificity of the expert and novice ultrasound examinations were compared to gold standard radiography. Results: Over 800 patients were enrolled in this study. The sensitivity and specificity of expert performed ultrasound exceeded 98% for MSK injuries. Novice operators achieved 97% sensitivity and 99% specificity for targeted examinations with the greatest error in fractures involving the hand and foot. Conclusion: Point of care ultrasound is a sensitive and specific diagnostic test for MSK injury when performed by experts and just-in-time trained novice operators
    • …
    corecore