7 research outputs found

    Elbow Joint Loads during Simulated Activities of Daily Living:Implications for Formulating Recommendations after Total Elbow Arthroplasty.

    Get PDF
    Background: Overloading of the elbow joint prosthesis following total elbow arthroplasty can lead to implant failure. Joint moments during daily activities are not well-contextualized for a prosthesis' failure limits and the effect of the current postoperative instruction on elbow joint loading is unclear. This study investigates the difference in elbow joint moments between simulated daily tasks and between flexion-extension, pronation-supination, varus-valgus movement directions. Additionally, the effect of the current postoperative instruction on elbow joint load is examined.Methods: Nine healthy participants (age 45.8 ± 17 years, 3 males) performed eight tasks; driving a car, opening a door, rising from chair, lifting, sliding, combing hair, drinking, emptying cup, without and with the instruction "not lifting more than 1 kg". Upper limb kinematics and hand contact forces were measured. Elbow joint angles and net moments were analyzed using inverse dynamic analysis, where the net moments are estimated from movement data and external forces.Results: Peak elbow joint moments differed significantly between tasks (p &lt; 0.01) and movement directions (p &lt; 0.01). The most and least demanding tasks were, rising from a chair (13.4 Nm extension, 5.0 Nm supination, 15.2 Nm valgus) and sliding (4.3 Nm flexion, 1.7 Nm supination, 2.6 Nm varus). Net moments were significantly reduced after instruction only in the chair task (p &lt; 0.01).Conclusion: This study analyzed elbow joint moments in different directions during daily tasks. The outcomes question whether postoperative instruction can lead to decreasing elbow loads. Future research might focus on reducing elbow loads in the flexion-extension and varus-valgus directions.<br/

    Epidemiology and etiology of Parkinson’s disease: a review of the evidence

    Full text link

    Elbow joint biomechanics during ADL focusing on total elbow arthroplasty - a scoping review

    Get PDF
    Abstract Background Overloading is hypothesized to be one of the failure mechanisms following total elbow arthroplasty (TEA). It is unclear whether the current post-operative loading instruction is compliant with reported failure mechanisms. Aim is therefore to evaluate the elbow joint load during activities of daily living (ADL) and compare these loads with reported failure limits from retrieval and finite element studies. Methods A scoping review of studies until 23 November 2021 investigating elbow joint load during ADL were identified by searching PubMed/Medline and Web of Science. Studies were eligible when: (1) reporting on the elbow joint load in native elbows or elbows with an elbow arthroplasty in adults; (2) full-text article was available. Results Twenty-eight studies with a total of 256 participants were included. Methodological quality was low in 3, moderate in 22 and high in 3 studies. Studies were categorized as 1) close to the body and 2) further away from the body. Tasks were then subdivided into: 1) cyclic flexion/extension, 2) push-up, 3) reaching, 4) self-care, 5) work. Mean flexion–extension joint load was 17 Nm, mean varus-valgus joint load 9 Nm, mean pronation-supination joint load 8 Nm and mean bone-on-bone contact force 337 N. Conclusion The results of our scoping review give a first overview of the current knowledge on elbow joint loads during ADL. Surprisingly, the current literature is not sufficient to formulate a postoperative instruction for elbow joint loading, which is compliant with failure limits of the prosthesis. In addition, our current instruction does not appear to be evidence-based. Our recommendations offer a starting point to assist clinicians in providing informed decisions about post-operative instructions for their patients

    Elbow joint biomechanics during ADL focusing on total elbow arthroplasty - a scoping review

    No full text
    Background: Overloading is hypothesized to be one of the failure mechanisms following total elbow arthroplasty (TEA). It is unclear whether the current post-operative loading instruction is compliant with reported failure mechanisms. Aim is therefore to evaluate the elbow joint load during activities of daily living (ADL) and compare these loads with reported failure limits from retrieval and finite element studies. Methods: A scoping review of studies until 23 November 2021 investigating elbow joint load during ADL were identified by searching PubMed/Medline and Web of Science. Studies were eligible when: (1) reporting on the elbow joint load in native elbows or elbows with an elbow arthroplasty in adults; (2) full-text article was available. Results: Twenty-eight studies with a total of 256 participants were included. Methodological quality was low in 3, moderate in 22 and high in 3 studies. Studies were categorized as 1) close to the body and 2) further away from the body. Tasks were then subdivided into: 1) cyclic flexion/extension, 2) push-up, 3) reaching, 4) self-care, 5) work. Mean flexion–extension joint load was 17 Nm, mean varus-valgus joint load 9 Nm, mean pronation-supination joint load 8 Nm and mean bone-on-bone contact force 337 N. Conclusion: The results of our scoping review give a first overview of the current knowledge on elbow joint loads during ADL. Surprisingly, the current literature is not sufficient to formulate a postoperative instruction for elbow joint loading, which is compliant with failure limits of the prosthesis. In addition, our current instruction does not appear to be evidence-based. Our recommendations offer a starting point to assist clinicians in providing informed decisions about post-operative instructions for their patients

    Elbow joint biomechanics during ADL focusing on total elbow arthroplasty - a scoping review

    No full text
    Abstract Background Overloading is hypothesized to be one of the failure mechanisms following total elbow arthroplasty (TEA). It is unclear whether the current post-operative loading instruction is compliant with reported failure mechanisms. Aim is therefore to evaluate the elbow joint load during activities of daily living (ADL) and compare these loads with reported failure limits from retrieval and finite element studies. Methods A scoping review of studies until 23 November 2021 investigating elbow joint load during ADL were identified by searching PubMed/Medline and Web of Science. Studies were eligible when: (1) reporting on the elbow joint load in native elbows or elbows with an elbow arthroplasty in adults; (2) full-text article was available. Results Twenty-eight studies with a total of 256 participants were included. Methodological quality was low in 3, moderate in 22 and high in 3 studies. Studies were categorized as 1) close to the body and 2) further away from the body. Tasks were then subdivided into: 1) cyclic flexion/extension, 2) push-up, 3) reaching, 4) self-care, 5) work. Mean flexion–extension joint load was 17 Nm, mean varus-valgus joint load 9 Nm, mean pronation-supination joint load 8 Nm and mean bone-on-bone contact force 337 N. Conclusion The results of our scoping review give a first overview of the current knowledge on elbow joint loads during ADL. Surprisingly, the current literature is not sufficient to formulate a postoperative instruction for elbow joint loading, which is compliant with failure limits of the prosthesis. In addition, our current instruction does not appear to be evidence-based. Our recommendations offer a starting point to assist clinicians in providing informed decisions about post-operative instructions for their patients

    Letter. Magnitude and distribution of linkage disequilibrium in population isolates and implications for genome-wide association studies

    No full text
    The genome-wide distribution of linkage disequilibrium (LD) determines the strategy for selecting markers for association studies, but it varies between populations. We assayed LD in large samples (200 individuals) from each of 11 well-described population isolates and an outbred European-derived sample, using SNP markers spaced across chromosome 22. Most isolates show substantially higher levels of LD than the outbred sample and many fewer regions of very low LD (termed 'holes'). Young isolates known to have had relatively few founders show particularly extensive LD with very few holes; these populations offer substantial advantages for genome-wide association mapping

    Mouse Models of Huntington’s Disease

    No full text
    corecore