14 research outputs found
Electrochemical method for the determination of arsenic 'in the field' using screen-printed grid electrodes
This project describes development and problem solving efforts to realise a viable
portable sensor for arsenic, applicable to drinking water. The work is the first
dedicated effort towards this goal, after the preliminary investigations previously
conducted at Cranfield University (Cooper, 2004 and Noh, 2005). Using polymeric
gold ink BQ331 (DuPont Microcircuit Materials, Bristol, UK) as working electrode
on screen printed strips, the electrochemical procedure was studied. Due to the wealth
of research on electrochemical and non electrochemical methods for arsenic
determination, this project attempts to capitalise on the unique advantages of the
screen-printed gold surface.
In particular, the issues surrounding the performance of the sensor were evaluated by
electrochemical and spectroscopic means (including infrared, nuclear magnetic
resonance and X-ray photoelectron spectroscopy). A number of custom screen printed
electrodes were prepared in house comparing sensor performance on compositional
factors. An interference coming from silver interaction with chloride in the reference
electrode was identified. As such, the design of the sensor needs to change to include
either an immobilising layer, such as Nafion, over the silver, or to omit screen-printed
silver altogether. The Nafion was presumed to work by excluding (or at least much
reducing) the passage of negatively charged chloride ions to the silver surface
preventing formation of soluble silver chloride complexes.
The design of the sensor was considered in light of performance and sensitivity. The
screen-printed electrodes were cut to facilitate a microband design lending favourable
diffusive to capacitive current characteristics. With this design, As(III) detection was
demonstrated comfortably at 5 ppb (in a copper tolerant 4 M HCl electrolyte) without
electrode need for additional preparation procedures. This is below the World Health
Organisation (WHO) guideline and United States Environmental Protection Agency
(USEPA) regulation level of 10 ppb in drinking water. The electrode materials are
already mass manufacturable at an estimated cost less than ÂŁ 0.5 per electrode. Themicroband design could, in principle, be applied to mercury and other metal ions. The
procedure for As(V) either with chemical or electrochemical reduction and
determination still needs to be assessed. However, the presented electrode system
offers a viable alternative to the colorimetric test kits presently employed around the
world for arsenic in drinking water.
Also, the Nicholson Method (Nicholson, 1965a), used for characterising electron
transfer kinetics at electrode surfaces, was extended for application to rough surfaces
using a fractal parameter introduced by Nyikos and Pajkossy (1988). This work
includes mathematical derivation and numerical evaluation and gives a number of
predictions for electrochemical behaviour. These predictions could not be tested
experimentally, as yet, since the physical conditions must be carefully controlled
Microband sensor for As(III) analysis: Reduced matrix interference
A portable sensor based on a microband design for arsenic detection in drinking water is presented. The work was focused to minimize interference encountered with a standard screen-printed electrodes featuring an onboard gold working electrode, carbon counter and silverâsilver chloride pseudo-reference electrodes as composite coatings on plastic surface. The interference effect was identified as chloride ions interacting with the silver surface of the reference electrode and formation of soluble silver chloride complexes such as AgCl43â. By modification of the reference electrodes with Nafion membrane (5â% in alcohols), the interference was entirely eliminated. However, membrane coverage and uniformity can impact the electrodes reproducibility and performance. Hence, the sensor design was further considered and a microband format was produced lending favorable diffusive to capacitive current characteristics. Using the microband electrodes allowed As(III) detection with limit of detection of 0.8â
ppb (in 4â
M HCl electrolyte), inherently avoiding the problems of electrode fouling and maximizing analyte signal in river water samples. This is below the World Health Organization limit of 10â
ÎŒgâLâ1 (ppb). The electrolyte system was chosen so as to avoid problems from other common metal ions, most notably Cu(II). The presented electrode system is cost effective and offers a viable alternative to the colorimetric test kits presently employed for arsenic analysis in drinking water
Electrochemical method for the determination of arsenic 'in the field' using screen-printed gold electrodes
This project describes development and problem solving efforts to realise a viable portable sensor for arsenic, applicable to drinking water. The work is the first dedicated effort towards this goal, after the preliminary investigations previously conducted at Cranfield University (Cooper, 2004 and Noh, 2005). Using polymeric gold ink BQ331 (DuPont Microcircuit Materials, Bristol, UK) as working electrode on screen printed strips, the electrochemical procedure was studied. Due to the wealth of research on electrochemical and non electrochemical methods for arsenic determination, this project attempts to capitalise on the unique advantages of the screen-printed gold surface. In particular, the issues surrounding the performance of the sensor were evaluated by electrochemical and spectroscopic means (including infrared, nuclear magnetic resonance and X-ray photoelectron spectroscopy). A number of custom screen printed electrodes were prepared in house comparing sensor performance on compositional factors. An interference coming from silver interaction with chloride in the reference electrode was identified. As such, the design of the sensor needs to change to include either an immobilising layer, such as Nafion, over the silver, or to omit screen-printed silver altogether. The Nafion was presumed to work by excluding (or at least much reducing) the passage of negatively charged chloride ions to the silver surface preventing formation of soluble silver chloride complexes. The design of the sensor was considered in light of performance and sensitivity. The screen-printed electrodes were cut to facilitate a microband design lending favourable diffusive to capacitive current characteristics. With this design, As(III) detection was demonstrated comfortably at 5 ppb (in a copper tolerant 4 M HCl electrolyte) without electrode need for additional preparation procedures. This is below the World Health Organisation (WHO) guideline and United States Environmental Protection Agency (USEPA) regulation level of 10 ppb in drinking water. The electrode materials are already mass manufacturable at an estimated cost less than ÂŁ 0.5 per electrode. Themicroband design could, in principle, be applied to mercury and other metal ions. The procedure for As(V) either with chemical or electrochemical reduction and determination still needs to be assessed. However, the presented electrode system offers a viable alternative to the colorimetric test kits presently employed around the world for arsenic in drinking water. Also, the Nicholson Method (Nicholson, 1965a), used for characterising electron transfer kinetics at electrode surfaces, was extended for application to rough surfaces using a fractal parameter introduced by Nyikos and Pajkossy (1988). This work includes mathematical derivation and numerical evaluation and gives a number of predictions for electrochemical behaviour. These predictions could not be tested experimentally, as yet, since the physical conditions must be carefully controlled.EThOS - Electronic Theses Online ServiceGBUnited Kingdo
Empirical models of the electron concentration of the ionosphere and their value for radio communications purposes
The availability of representative empirical models of the variation of the electron concentration with height in the ionosphere is one critical element in the development of practical schemes for providing reliable HF radio propagation predictions. The degree to which a specific model succeeds must be judged against three criteria: (1) quality of profile match: the model must reproduce the range of N(h) profiles encountered in practice; this match should be maintained in the first and second derivatives with height; (2) availability and simplicity of the external data required for profile specification: input data which consist of only those parameters routinely scaled from ionograms and available from CCIR predictions best fit this criterion; (3) numerical complexity: preferably the mathematical algorithms describing the model should be as simple as possible. These criteria conflict so that schemes have been developed optimized with respect to one or two of them at the expense of the other(s), the choice being driven by the application. In this paper, four such schemes are reviewed and contrasted in the light of these criteria and usage in practice. It is concluded that the Booker (1977) âskeletonâ profile approach is best for simulating a known profile for precision radio wave studies, while the Dudeney (1978) technique provides good overall performance for general purpose communications predictions. The performance of the scheme currently recommended by the CCIR (Bradley and Dudeney, 1973a) cannot match these two, and should be superceded except where the need for mathematical simplicity is of overriding importance. The International Reference Ionosphere profile is found to have significant disadvantages for communications work with respect to all three criteria
Magnitude and timing of nictitating membrane movements during classical conditioning of the rabbit (Oryctolagus cuniculus).
A trial-by-trial, subject-by-subject analysis was conducted to determine whether generation of the conditioned response (CR) occurs on a continuous or all-or-none basis. Three groups of rabbits were trained on different partial reinforcement schedules with the conditioned stimulus presented alone on 10%, 30%, or 50%, respectively, of all trials. Plots of each rabbit's nictitating membrane movements revealed that their magnitude rose in a continuous fashion. Response growth during acquisition followed a sigmoidal curve, and the timing of CR-sized movements was largely stable throughout the experiment. The results are discussed with respect to alternative models of CR generation