    First-in-human technique translation of oxygen-enhanced MRI to an MR Linac system in patients with head and neck cancer

    Get PDF
    BACKGROUND AND PURPOSE: Tumour hypoxia is prognostic in head and neck cancer (HNC), associated with poor loco-regional control, poor survival and treatment resistance. The advent of hybrid MRI - radiotherapy linear accelerator or 'MR Linac' systems - could permit imaging for treatment adaptation based on hypoxic status. We sought to develop oxygen-enhanced MRI (OE-MRI) in HNC and translate the technique onto an MR Linac system. MATERIALS AND METHODS: MRI sequences were developed in phantoms and 15 healthy participants. Next, 14 HNC patients (with 21 primary or local nodal tumours) were evaluated. Baseline tissue longitudinal relaxation time (T1) was measured alongside the change in 1/T1 (termed ΔR1) between air and oxygen gas breathing phases. We compared results from 1.5 T diagnostic MR and MR Linac systems. RESULTS: Baseline T1 had excellent repeatability in phantoms, healthy participants and patients on both systems. Cohort nasal concha oxygen-induced ΔR1 significantly increased (p < 0.0001) in healthy participants demonstrating OE-MRI feasibility. ΔR1 repeatability coefficients (RC) were 0.023-0.040 s-1 across both MR systems. The tumour ΔR1 RC was 0.013 s-1 and the within-subject coefficient of variation (wCV) was 25% on the diagnostic MR. Tumour ΔR1 RC was 0.020 s-1 and wCV was 33% on the MR Linac. ΔR1 magnitude and time-course trends were similar on both systems. CONCLUSION: We demonstrate first-in-human translation of volumetric, dynamic OE-MRI onto an MR Linac system, yielding repeatable hypoxia biomarkers. Data were equivalent on the diagnostic MR and MR Linac systems. OE-MRI has potential to guide future clinical trials of biology guided adaptive radiotherapy

    Initial Clinical Experience of MR-Guided Radiotherapy for Non-Small Cell Lung Cancer.

    Get PDF
    Curative-intent radiotherapy plays an integral role in the treatment of lung cancer and therefore improving its therapeutic index is vital. MR guided radiotherapy (MRgRT) systems are the latest technological advance which may help with achieving this aim. The majority of MRgRT treatments delivered to date have been stereotactic body radiation therapy (SBRT) based and include the treatment of (ultra-) central tumors. However, there is a move to also implement MRgRT as curative-intent treatment for patients with inoperable locally advanced NSCLC. This paper presents the initial clinical experience of using the two commercially available systems to date: the ViewRay MRIdian and Elekta Unity. The challenges and potential solutions associated with MRgRT in lung cancer will also be highlighted

    Reirradiation Options for Previously Irradiated Prostate cancer (RO-PIP): Feasibility study investigating toxicity outcomes following reirradiation with stereotactic body radiotherapy (SBRT) versus high-dose-rate brachytherapy (HDR-BT).

    Get PDF
    IntroductionRadiotherapy is the most common curative treatment for non-metastatic prostate cancer; however, up to 13% of patients will develop local recurrence within 10 years. Patients can undergo further and potentially curative treatment including salvage surgery, brachytherapy (BT), external beam radiotherapy, high-intensity focused ultrasound and cryotherapy. Systematic review shows that high-dose-rate (HDR) BT and stereotactic body radiotherapy (SBRT) have the best outcomes in terms of biochemical control and lowest side effects. The reirradiation options for previously irradiated prostate cancer (RO-PIP) trial aims to determine the feasibility of recruitment to a trial randomising patients to salvage HDR-BT or SBRT and provide prospective data on patient recorded toxicity outcomes that will inform a future phase III trial.Methods and analysisThe primary endpoint of the RO-PIP feasibility study is to evaluate the patient recruitment potential over 2 years to a trial randomising to either SBRT or HDR-BT for patients who develop local recurrence of prostate cancer following previous radiation therapy. The aim is to recruit 60 patients across 3 sites over 2 years and randomise 1:1 to SBRT or HDR-BT. Secondary objectives include recording clinician and patient-reported outcome measures to evaluate treatment-related toxicity. In addition, the study aims to identify potential imaging, genomic and proteomic biomarkers that are predictive of toxicity and outcome based on hypoxia status, a prognostic marker of prostate cancer.Ethics and disseminationThis study has been approved by the Yorkshire and The Humber-Bradford Leeds Research Ethics Committee (Reference: 21/YH/0305, IRAS: 297060, January 2022). The results will be presented in national and international conferences, published in peer-reviewed journals and will be communicated to relevant stakeholders. A plain English report will be shared with the study participants, patients' organisations and media.Trial registration numberISRCTN 12238218 (Amy Ackroyd NIHR CPMS Team)

    Magnetic resonance imaging in precision radiation therapy for lung cancer

    No full text
    Radiotherapy remains the cornerstone of curative treatment for inoperable locally advanced lung cancer, given concomitantly with platinum-based chemotherapy. With poor overall survival, research efforts continue to explore whether integration of advanced radiation techniques will assist safe treatment intensification with the potential for improving outcomes. One advance is the integration of magnetic resonance imaging (MRI) in the treatment pathway, providing anatomical and functional information with excellent soft tissue contrast without exposure of the patient to radiation. MRI may complement or improve the diagnostic staging accuracy of F-18 fluorodeoxyglucose position emission tomography and computerized tomography imaging, particularly in assessing local tumour invasion and is also effective for identification of nodal and distant metastatic disease. Incorporating anatomical MRI sequences into lung radiotherapy treatment planning is a novel application and may improve target volume and organs at risk delineation reproducibility. Furthermore, functional MRI may facilitate dose painting for heterogeneous target volumes and prediction of normal tissue toxicity to guide adaptive strategies. MRI sequences are rapidly developing and although the issue of intra-thoracic motion has historically hindered the quality of MRI due to the effect of motion, progress is being made in this field. Four-dimensional MRI has the potential to complement or supersede 4D CT and 4D F-18-FDG PET, by providing superior spatial resolution. A number of MR-guided radiotherapy delivery units are now available, combining a radiotherapy delivery machine (linear accelerator or cobalt-60 unit) with MRI at varying magnetic field strengths. This novel hybrid technology is evolving with many technical challenges to overcome. It is anticipated that the clinical benefits of MR-guided radiotherapy will be derived from the ability to adapt treatment on the fly for each fraction and in real-time, using 'beam-on' imaging. The lung tumour site group of the Atlantic MR-Linac consortium is working to generate a challenging MR-guided adaptive workflow for multi-institution treatment intensification trials in this patient group

    MRI commissioning of 1.5T MR-linac systems – a multi-institutional study

    No full text
    Background: Magnetic Resonance linear accelerator (MR-linac) systems represent a new type of technology that allows for online MR-guidance for high precision radiotherapy (RT). Currently, the first MR-linac installations are being introduced clinically. Since the imaging performance of these integrated MR-linac systems is critical for their application, a thorough commissioning of the MRI performance is essential. However, guidelines on the commissioning of MR-guided RT systems are not yet defined and data on the performance of MR-linacs are not yet available. Materials & methods: Here we describe a comprehensive commissioning protocol, which contains standard MRI performance measurements as well as dedicated hybrid tests that specifically assess the interactions between the Linac and the MRI system. The commissioning results of four MR-linac systems are presented in a multi-center study. Results: Although the four systems showed similar performance in all the standard MRI performance tests, some differences were observed relating to the hybrid character of the systems. Field homogeneity measurements identified differences in the gantry shim configuration, which was later confirmed by the vendor. Conclusion: Our results highlight the importance of dedicated hybrid commissioning tests and the ability to compare the machines between institutes at this very early stage of clinical introduction. Until formal guidelines and tolerances are defined the tests described in this study may be used as a practical guideline. Moreover, the multi-center results provide initial bench mark data for future MR-linac installations
    corecore