1,224 research outputs found
A Cosmic Ray Measurement Facility for ATLAS Muon Chambers
Monitored Drift Tube (MDT) chambers will constitute the large majority of
precision detectors in the Muon Spectrometer of the ATLAS experiment at the
Large Hadron Collider at CERN. For commissioning and calibration of MDT
chambers, a Cosmic Ray Measurement Facility is in operation at Munich
University. The objectives of this facility are to test the chambers and
on-chamber electronics, to map the positions of the anode wires within the
chambers with the precision needed for standalone muon momentum measurement in
ATLAS, and to gain experience in the operation of the chambers and on-line
calibration procedures.
Until the start of muon chamber installation in ATLAS, 88 chambers built at
the Max Planck Institute for Physics in Munich have to be commissioned and
calibrated. With a data taking period of one day individual wire positions can
be measured with an accuracy of 8.3 micrometers in the chamber plane and 27
micrometers in the direction perpendicular to that plane.Comment: 14+1 pages, 11 figures, contributed paper to the EPS2003 conference,
Aache
Rate effects in high-resolution drift chambers
The impact of high counting rates on the spatial resolution of cylindrical drift tubes is investigated in detail and the results are compared with simulations. Electronics effects and space-charge effects are quantitatively analysed. A spatial resolution of can be achieved even at rates as high as 1500\,Hz/cm wire length (300\,kHz per wire)
Resolution limits of drift tubes
Measurements of the drift-tube response to charged particle tracks are compared with a complete simulation. The measured resolution of typically 80\,m agrees well with the simulation and allows the individual factors limiting the resolution such as diffusion, charge deposit fluctuations, gas gain fluctuations and signal processing to be studied. The results with respect to the dependence of the drift chamber resolution on gas gain, gas pressure and electronics parameters are reported
Front-end electronics for drift tubes in a high-rate environment
A front-end electronics readout for drift tubes in a high-rate environment is presented. This system allows us to encode several pieces of information (leading edge time, trailing edge time, signal charge and piled-up hits from multiple tracks) into a single readout channel that is presented to the TDC. The advantage of active baseline restoration compared to bipolar signal shaping is discussed
Dependence of Drift Tube Performance on the Anode Wire Diameter
Cylindrical pressurized drift tubes with different anode wire diameters wereoperated in a 170~GeV muon test beam. The dependences of spatialresolution, efficiency and streamer probability on the anode wirediameter were measured. The resolution measurements are compared with a simulation
Sedentary behavior and subclinical atherosclerosis in African Americans: cross-sectional analysis of the Jackson heart study
BACKGROUND: Previous studies have reported conflicting results as to whether an association exists between sedentary time and cardiovascular disease (CVD) risk among African Americans. These studies, however, were limited by lack of consideration of sedentary behavior in leisure versus non-leisure settings. To elucidate this relation, we investigated the associations of television (TV) viewing time and occupational sitting with carotid intima-media thickness (CIMT), a subclinical atherosclerosis measure, in a community-based sample of African Americans. METHODS: We studied 3410 participants from the Jackson Heart Study, a single-site, community-based study of African Americans residing in Jackson, MS. CIMT was assessed by ultrasonography and represented mean far-wall thickness across right and left sides of the common carotid artery. TV viewing time, a measure of leisure sedentary behavior, and occupational sitting, a measure of non-leisure sedentary behavior, were assessed by questionnaire. RESULTS: In a multivariable regression model that included physical activity and CVD risk factors, longer TV viewing time (2-4 h/day and >4 h/day) was associated with greater CIMT (adjusted mean ± SE difference from referent [4 h/day; P-trend =0.001). In contrast, more frequent occupational sitting ('sometimes' and 'often/always') was associated with lower CIMT (adjusted mean ± SE difference from referent ['never/seldom']:-0.021 ± 0.009 mm for 'sometimes', and-0.018 ± 0.008 mm for 'often/always'; P-trend = 0.042). CONCLUSIONS: Longer TV viewing time was associated with greater CIMT, while occupational sitting was associated with lower CIMT. These findings suggest the role of sedentary behaviors in the pathogenesis of CVD among African Americans may vary by whether individuals engage in leisure versus non-leisure sedentary behaviors
Wii-Fit for Improving Gait and Balance in an Assisted Living Facility: A Pilot Study
Objectives. To determine the effects on balance and gait of a Wii-Fit program compared to a walking program in subjects with mild Alzheimer's dementia (AD). Methods. A prospective randomized (1 : 1) pilot study with two intervention arms was conducted in an assisted living facility with twenty-two mild AD subjects. In both groups the intervention occurred under supervision for 30 minutes daily, five times a week for eight weeks. Repeated measures ANOVA and paired t-tests were used to analyze changes. Results. Both groups showed improvement in Berg Balance Scale (BBS), Tinetti Test (TT) and Timed Up and Go (TUG) over 8 weeks. However, there was no statistically significant difference between the groups over time. Intragroup analysis in the Wii-Fit group showed significant improvement on BBS (P = 0.003), and TT (P = 0.013). The walking group showed a trend towards improvement on BBS (P = 0.06) and TUG (P = 0.07) and significant improvement in TT (P = 0.06). Conclusion. This pilot study demonstrates the safety and efficacy of Wii-Fit in an assisted living facility in subjects with mild AD. Use of Wii-Fit resulted in significant improvements in balance and gait comparable to those in the robust monitored walking program. These results need to be confirmed in a larger, methodologically sound study
Measurement of the hadronic photon structure function F_{2}^{γ} at LEP2
The hadronic structure function of the photon F_{2}^{γ} (x, Q²) is measured as a function of Bjorken x and of the photon virtuality Q² using deep-inelastic scattering data taken by the OPAL detector at LEP at e⁺e⁻ centre-of-mass energies from 183 to 209 GeV. Previous OPAL measurements of the x dependence of F_{2}^{γ} are extended to an average Q² of 〈Q²〉=780 GeV² using data in the kinematic range 0.15<x<0.98. The Q² evolution of F_{2}^{γ} is studied for 12.1<〈Q²〉<780 GeV² using three ranges of x. As predicted by QCD, the data show positive scaling violations in F_{2}^{γ} with F_{2}^{γ} (Q²)/α = (0.08±0.02⁺⁰·⁰⁵_₀.₀₃) + (0.13±0.01⁺⁰·⁰¹_₀.₀₁) lnQ², where Q² is in GeV², for the central x region 0.10–0.60. Several parameterisations of F_{2}^{γ} are in qualitative agreement with the measurements whereas the quark-parton model prediction fails to describe the data
Measurement of the charm structure function F_{2,c)^{γ} of the photon at LEP
The production of charm quarks is studied in deep-inelastic electron–photon scattering using data recorded by the OPAL detector at LEP at nominal e⁺e⁻ centre-of-mass energies from 183 to 209 GeV. The charm quarks have been identified by full reconstruction of charged D* mesons using their decays into D⁰π with the D⁰ observed in two decay modes with charged particle final states, Kπ and Kπππ. The cross-section σ^{D*} for production of charged D* in the reaction e⁺e⁻→e⁺e⁻D*Χ is measured in a restricted kinematical region using two bins in Bjorken x, 0.00140.1 the perturbative QCD calculation at next-to-leading order agrees perfectly with the measured cross-section. For x<0.1 the measured cross-section is 43.8±14.3±6.3±2.8 pb with a next-to-leading order prediction of 17.0⁺²·⁹_₂.₃ pb
Determination of alpha_s using Jet Rates at LEP with the OPAL detector
Hadronic events produced in e+e- collisions by the LEP collider and recorded
by the OPAL detector were used to form distributions based on the number of
reconstructed jets. The data were collected between 1995 and 2000 and
correspond to energies of 91 GeV, 130-136 GeV and 161-209 GeV. The jet rates
were determined using four different jet-finding algorithms (Cone, JADE, Durham
and Cambridge). The differential two-jet rate and the average jet rate with the
Durham and Cambridge algorithms were used to measure alpha(s) in the LEP energy
range by fitting an expression in which order alpah_2s calculations were
matched to a NLLA prediction and fitted to the data. Combining the measurements
at different centre-of-mass energies, the value of alpha_s (Mz) was determined
to be
alpha(s)(Mz)=0.1177+-0.0006(stat.)+-0.0012$(expt.)+-0.0010(had.)+-0.0032(theo.)
\.Comment: 40 pages, 17 figures, Submitted to Euro. Phys. J.
- …