5 research outputs found

    High voltage test bench for heavy ion beam probe diagnostics on T-15MD tokamak

    Get PDF
    D-shaped tokamak T-15MD is nowunder construction in the NRC β€œKurchatov Institute”. Heavy ion beam probing (HIBP) is an important part of T-15MD diagnostic system. Calculations of the probing ions trajectories show that the beam will pass through the plasma about 1.0…1.5 m, which can lead to its significant attenuation. HIBP operation requires obtaininga high-current long-focus probing beam of Tl+ ions (I = 200…400 ΞΌA, f = 4…6 m, d ≀ 10 mm). A high voltage (300 keV) test-benchto test such beams is eing created now. Numerical modeling shows the possibility of a beam formation with a current of 300 ΞΌA and diameter 12 mm at 6 m from the ion emitter.Π—Π°Ρ€Π°Π· Π² НДЦ Β«ΠšΡƒΡ€Ρ‡Π°Ρ‚ΠΎΠ²ΡΡŒΠΊΠΈΠΉ інститут» Π²Π΅Π΄Π΅Ρ‚ΡŒΡΡ Π±ΡƒΠ΄Ρ–Π²Π½ΠΈΡ†Ρ‚Π²ΠΎ Ρ‚ΠΎΠΊΠ°ΠΌΠ°ΠΊΠ° Π”-ΠΎΠ±Ρ€Π°Π·Π½ΠΎΠ³ΠΎ ΠΏΠ΅Ρ€Π΅Ρ€Ρ–Π·Ρƒ Π’-15ΠœΠ”. Зондування ΠΏΡƒΡ‡ΠΊΠΎΠΌ Π²Π°ΠΆΠΊΠΈΡ… Ρ–ΠΎΠ½Ρ–Π² (Π—ΠŸΠ’Π†) Ρ” ваТливою Ρ‡Π°ΡΡ‚ΠΈΠ½ΠΎΡŽ діагностичного комплСксу Π’-15ΠœΠ”. Π ΠΎΠ·Ρ€Π°Ρ…ΡƒΠ½ΠΊΠΈ Ρ‚Ρ€Π°Ρ”ΠΊΡ‚ΠΎΡ€Ρ–ΠΉ Π·ΠΎΠ½Π΄ΡƒΠ²Π°Π»ΡŒΠ½ΠΈΡ… Ρ–ΠΎΠ½Ρ–Π² ΠΏΠΎΠΊΠ°Π·ΡƒΡŽΡ‚ΡŒ, Ρ‰ΠΎ ΠΏΡƒΡ‡ΠΎΠΊ Π±ΡƒΠ΄Π΅ ΠΏΡ€ΠΎΡ…ΠΎΠ΄ΠΈΡ‚ΠΈ Ρƒ ΠΏΠ»Π°Π·ΠΌΡ– ΡˆΠ»ΡΡ… довТиною 1,0…1,5 ΠΌ, Ρ‰ΠΎ ΠΌΠΎΠΆΠ΅ ΠΏΡ€ΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚ΠΈ Π΄ΠΎ Π·Π½Π°Ρ‡Π½ΠΎΠ³ΠΎ ΠΉΠΎΠ³ΠΎ ослаблСння. Для забСзпСчСння моТливості Π²ΠΈΠΌΡ–Ρ€ΡŽΠ²Π°Π½ΡŒ ΠΏΠ°Ρ€Π°ΠΌΠ΅Ρ‚Ρ€Ρ–Π² ΠΏΠ»Π°Π·ΠΌΠΈ ΠΏΠΎΡ‚Ρ€Ρ–Π±Π½ΠΎ ΠΎΡ‚Ρ€ΠΈΠΌΠ°Ρ‚ΠΈ ΡΠΈΠ»ΡŒΠ½ΠΎΡΡ‚Ρ€ΡƒΠΌΠΎΠ²ΠΈΡ… довгофокусних Π·ΠΎΠ½Π΄ΡƒΠ²Π°Π»ΡŒΠ½ΠΈΡ… ΠΏΡƒΡ‡ΠΊΡ–Π² Tl+ (I = 200…400 мкА, f = 4…6 ΠΌ, d ≀ 10 ΠΌΠΌ). На Π΄Π°Π½ΠΈΠΉ час Ρƒ ΠšΡƒΡ€Ρ‡Π°Ρ‚ΠΎΠ²ΡΡŒΠΊΠΎΠΌΡƒ інституті ΡΡ‚Π²ΠΎΡ€ΡŽΡ”Ρ‚ΡŒΡΡ діагностичний стСнд для Π²ΠΈΡ€Ρ–ΡˆΠ΅Π½Π½Ρ Ρ†Ρ–Ρ”Ρ— Π·Π°Π΄Π°Ρ‡Ρ–. На Ρ†ΡŒΠΎΠΌΡƒ стСнді Π±ΡƒΠ΄ΡƒΡ‚ΡŒ проводитися СкспСримСнти ΠΏΠΎ Ρ„ΠΎΠΊΡƒΡΡƒΠ²Π°Π½Π½ΡŽ Ρ–ΠΎΠ½Π½ΠΈΡ… ΠΏΡƒΡ‡ΠΊΡ–Π² Π· Π΅Π½Π΅Ρ€Π³Ρ–Ρ”ΡŽ Π΄ΠΎ 300 ΠΊΠ΅Π’, Π° Ρ‚Π°ΠΊΠΎΠΆ вивчатися властивості Ρ‚Π΅Ρ€ΠΌΠΎΡ–ΠΎΠ½Π½ΠΈΡ… Π΅ΠΌΡ–Ρ‚Π΅Ρ€Ρ–Π² Ρ– час Ρ—Ρ… Тиття. Π ΠΎΠ·Ρ€Π°Ρ…ΡƒΠ½ΠΊΠΈ Ρ€ΡƒΡ…Ρƒ Ρ–ΠΎΠ½Ρ–Π² Π² Ρ–Π½ΠΆΠ΅ΠΊΡ‚ΠΎΡ€Ρ– ΠΏΠΎΠΊΠ°Π·ΡƒΡŽΡ‚ΡŒ ΠΌΠΎΠΆΠ»ΠΈΠ²Ρ–ΡΡ‚ΡŒ створСння ΠΏΡƒΡ‡ΠΊΠ° струмом 300 мкА, Π΄Ρ–Π°ΠΌΠ΅Ρ‚Ρ€ΠΎΠΌ 12 ΠΌΠΌ Π½Π° відстані 6 ΠΌ Π²Ρ–Π΄ Ρ–ΠΎΠ½Π½ΠΎΠ³ΠΎ Π΅ΠΌΡ–Ρ‚Π΅Ρ€Π°.Π’ НИЦ Β«ΠšΡƒΡ€Ρ‡Π°Ρ‚ΠΎΠ²ΡΠΊΠΈΠΉ институт» вСдСтся ΡΡ‚Ρ€ΠΎΠΈΡ‚Π΅Π»ΡŒΡΡ‚Π²ΠΎ Ρ‚ΠΎΠΊΠ°ΠΌΠ°ΠΊΠ° Π”-ΠΎΠ±Ρ€Π°Π·Π½ΠΎΠ³ΠΎ сСчСния Π’-15ΠœΠ”. Π—ΠΎΠ½Π΄ΠΈΡ€ΠΎΠ²Π°Π½ΠΈΠ΅ ΠΏΡƒΡ‡ΠΊΠΎΠΌ тяТСлых ΠΈΠΎΠ½ΠΎΠ² (Π—ΠŸΠ’Π˜) являСтся Π²Π°ΠΆΠ½ΠΎΠΉ Ρ‡Π°ΡΡ‚ΡŒΡŽ Π΅Π³ΠΎ диагностичСского комплСкса. РасчСты Ρ‚Ρ€Π°Π΅ΠΊΡ‚ΠΎΡ€ΠΈΠΉ Π·ΠΎΠ½Π΄ΠΈΡ€ΡƒΡŽΡ‰ΠΈΡ… ΠΈΠΎΠ½ΠΎΠ² ΠΏΠΎΠΊΠ°Π·Ρ‹Π²Π°ΡŽΡ‚, Ρ‡Ρ‚ΠΎ ΠΏΡƒΡ‡ΠΎΠΊ Π±ΡƒΠ΄Π΅Ρ‚ ΠΏΡ€ΠΎΡ…ΠΎΠ΄ΠΈΡ‚ΡŒ ΠΏΠΎ ΠΏΠ»Π°Π·ΠΌΠ΅ ΠΏΡƒΡ‚ΡŒ Π΄Π»ΠΈΠ½ΠΎΠΉ 1,0…1,5 ΠΌ, Ρ‡Ρ‚ΠΎ ΠΌΠΎΠΆΠ΅Ρ‚ ΠΏΡ€ΠΈΠ²ΠΎΠ΄ΠΈΡ‚ΡŒ ΠΊ Π·Π½Π°Ρ‡ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΌΡƒ Π΅Π³ΠΎ Π·Π°Ρ‚ΡƒΡ…Π°Π½ΠΈΡŽ. Π’ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ измСрСния ΠΏΠ°Ρ€Π°ΠΌΠ΅Ρ‚Ρ€ΠΎΠ² ΠΏΠ»Π°Π·ΠΌΡ‹ Ρ‚Ρ€Π΅Π±ΡƒΠ΅Ρ‚ получСния ΡΠΈΠ»ΡŒΠ½ΠΎΡ‚ΠΎΡ‡Π½Ρ‹Ρ… длиннофокусных Π·ΠΎΠ½Π΄ΠΈΡ€ΡƒΡŽΡ‰ΠΈΡ… ΠΏΡƒΡ‡ΠΊΠΎΠ² ΠΈΠΎΠ½ΠΎΠ² Tl+ (I = 200…400 мкА, f = 4…6 ΠΌ, d ≀ 10 ΠΌΠΌ). ВСстовый стСнд для этой Π·Π°Π΄Π°Ρ‡ΠΈ сСйчас создаСтся. На этом стСндС Π±ΡƒΠ΄ΡƒΡ‚ ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΡ‚ΡŒΡΡ экспСримСнты ΠΏΠΎ фокусировкС ΠΈΠΎΠ½Π½Ρ‹Ρ… ΠΏΡƒΡ‡ΠΊΠΎΠ² с энСргиСй Π΄ΠΎ 300 кэВ, Π° Ρ‚Π°ΠΊΠΆΠ΅ ΠΈΠ·ΡƒΡ‡Π°Ρ‚ΡŒΡΡ свойства Ρ‚Π΅Ρ€ΠΌΠΎΠΈΠΎΠ½Π½Ρ‹Ρ… эмиттСров ΠΈ врСмя ΠΈΡ… ΠΆΠΈΠ·Π½ΠΈ. РасчСты двиТСния заряТСнных частиц Π² ионнооптичСской систСмС ΠΈΠ½ΠΆΠ΅ΠΊΡ‚ΠΎΡ€Π° ΠΏΠΎΠΊΠ°Π·Ρ‹Π²Π°ΡŽΡ‚ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ создания ΠΏΡƒΡ‡ΠΊΠ° Ρ‚ΠΎΠΊΠΎΠΌ 300 мкА, Π΄ΠΈΠ°ΠΌΠ΅Ρ‚Ρ€ΠΎΠΌ 12 ΠΌΠΌ Π½Π° расстоянии 6 ΠΌ ΠΎΡ‚ ΠΈΠΎΠ½Π½ΠΎΠ³ΠΎ эмиттСра

    High-intensity cesium ion beams for HIBP diagnostics

    Get PDF
    The goal of the research is to expand the capabilities of the heavy ion beam probing (HIBP) diagnostic. HIBP is a unique diagnostic, capable to measure plasma potential, density and their fluctuations, as well as the poloidal magnetic field fluctuations in the core and edge plasmas. The sensitivity of the diagnostic is determined by the level of the output signal related to the instrumental noise. The level of the probing beam current should be as high as possible, especially for measurements at the periphery with low output signal due to low plasma density, and in the core, where the beam is attenuated due to the high plasma density. Optimization experiments have shown the possibility of ion beam forming in the current range from 40 to 800 ΞΌA.ΠœΠ΅Ρ‚Π° дослідТСння – Ρ€ΠΎΠ·ΡˆΠΈΡ€ΠΈΡ‚ΠΈ моТливості діагностики Π·Π° допомогою зондування ΠΏΠ»Π°Π·ΠΌΠΈ ΠΏΡƒΡ‡ΠΊΠΎΠΌ Π²Π°ΠΆΠΊΠΈΡ… Ρ–ΠΎΠ½Ρ–Π² (Π—ΠŸΠŸΠ’Π†). Π—ΠŸΠŸΠ’Π† – Ρ†Π΅ ΡƒΠ½Ρ–ΠΊΠ°Π»ΡŒΠ½Π° діагностика, Π·Π΄Π°Ρ‚Π½Π° Π²ΠΈΠΌΡ–Ρ€ΡŽΠ²Π°Ρ‚ΠΈ ΠΏΠΎΡ‚Π΅Π½Ρ†Ρ–Π°Π», густину ΠΏΠ»Π°Π·ΠΌΠΈ Ρ– Ρ—Ρ… Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†Ρ–Ρ—, Π° Ρ‚Π°ΠΊΠΎΠΆ Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†Ρ–Ρ— ΠΏΠΎΠ»ΠΎΡ–Π΄Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΠΌΠ°Π³Π½Ρ–Ρ‚Π½ΠΎΠ³ΠΎ поля Π² Ρ†Π΅Π½Ρ‚Ρ€Ρ– Ρ‚Π° ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€Ρ–Ρ— ΠΏΠ»Π°Π·ΠΌΠΈ. Π§ΡƒΡ‚Π»ΠΈΠ²Ρ–ΡΡ‚ΡŒ діагностики Π²ΠΈΠ·Π½Π°Ρ‡Π°Ρ”Ρ‚ΡŒΡΡ Ρ€Ρ–Π²Π½Π΅ΠΌ Π²ΠΈΡ…Ρ–Π΄Π½ΠΎΠ³ΠΎ сигналу, Ρ‰ΠΎΠ΄ΠΎ Ρ–Π½ΡΡ‚Ρ€ΡƒΠΌΠ΅Π½Ρ‚Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΡˆΡƒΠΌΡƒ. Π Ρ–Π²Π΅Π½ΡŒ струму Π·ΠΎΠ½Π΄ΡƒΠ²Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° ΠΏΠΎΠ²ΠΈΠ½Π΅Π½ Π±ΡƒΡ‚ΠΈ якомога Π±Ρ–Π»ΡŒΡˆ високим, особливо для Π²ΠΈΠΌΡ–Ρ€ΡŽΠ²Π°Π½ΡŒ Π½Π° ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€Ρ–Ρ— Π· низьким Π²ΠΈΡ…Ρ–Π΄Π½ΠΈΠΌ сигналом Ρ‡Π΅Ρ€Π΅Π· Π½ΠΈΠ·ΡŒΠΊΡƒ густину ΠΏΠ»Π°Π·ΠΌΠΈ, Π° Ρ‚Π°ΠΊΠΎΠΆ Ρƒ Ρ†Π΅Π½Ρ‚Ρ€Ρ–, Π΄Π΅ ΠΏΡƒΡ‡ΠΎΠΊ ΠΏΠΎΡΠ»Π°Π±Π»ΡŽΡ”Ρ‚ΡŒΡΡ Ρ‡Π΅Ρ€Π΅Π· високу густину ΠΏΠ»Π°Π·ΠΌΠΈ. ЕкспСримСнти Π· ΠΎΠΏΡ‚ΠΈΠΌΡ–Π·Π°Ρ†Ρ–Ρ— ΠΏΠΎΠΊΠ°Π·Π°Π»ΠΈ ΠΌΠΎΠΆΠ»ΠΈΠ²Ρ–ΡΡ‚ΡŒ формування Ρ–ΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° Π² Π΄Ρ–Π°ΠΏΠ°Π·ΠΎΠ½Ρ– струму 40…800 мкА.ЦСль исслСдования – Ρ€Π°ΡΡˆΠΈΡ€ΠΈΡ‚ΡŒ возмоТности диагностики с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ зондирования ΠΏΠ»Π°Π·ΠΌΡ‹ ΠΏΡƒΡ‡ΠΊΠΎΠΌ тяТСлых ΠΈΠΎΠ½ΠΎΠ² (Π—ΠŸΠŸΠ’Π˜). Π—ΠŸΠŸΠ’Π˜ – это ΡƒΠ½ΠΈΠΊΠ°Π»ΡŒΠ½Π°Ρ диагностика, способная ΠΈΠ·ΠΌΠ΅Ρ€ΡΡ‚ΡŒ ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π», ΠΏΠ»ΠΎΡ‚Π½ΠΎΡΡ‚ΡŒ ΠΏΠ»Π°Π·ΠΌΡ‹ ΠΈ ΠΈΡ… Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†ΠΈΠΈ, Π° Ρ‚Π°ΠΊΠΆΠ΅ Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†ΠΈΠΈ полоидального ΠΌΠ°Π³Π½ΠΈΡ‚Π½ΠΎΠ³ΠΎ поля Π² Ρ†Π΅Π½Ρ‚Ρ€Π΅ ΠΈ ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€ΠΈΠΈ ΠΏΠ»Π°Π·ΠΌΡ‹. Π§ΡƒΠ²ΡΡ‚Π²ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΡŒ диагностики опрСдСляСтся ΡƒΡ€ΠΎΠ²Π½Π΅ΠΌ Π²Ρ‹Ρ…ΠΎΠ΄Π½ΠΎΠ³ΠΎ сигнала ΠΎΡ‚Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ ΠΈΠ½ΡΡ‚Ρ€ΡƒΠΌΠ΅Π½Ρ‚Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΡˆΡƒΠΌΠ°. Π£Ρ€ΠΎΠ²Π΅Π½ΡŒ Ρ‚ΠΎΠΊΠ° Π·ΠΎΠ½Π΄ΠΈΡ€ΡƒΡŽΡ‰Π΅Π³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° Π΄ΠΎΠ»ΠΆΠ΅Π½ Π±Ρ‹Ρ‚ΡŒ ΠΊΠ°ΠΊ ΠΌΠΎΠΆΠ½ΠΎ Π±ΠΎΠ»Π΅Π΅ высоким, особСнно для ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ Π½Π° ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€ΠΈΠΈ с Π½ΠΈΠ·ΠΊΠΈΠΌ Π²Ρ‹Ρ…ΠΎΠ΄Π½Ρ‹ΠΌ сигналом ΠΈΠ·-Π·Π° Π½ΠΈΠ·ΠΊΠΎΠΉ плотности ΠΏΠ»Π°Π·ΠΌΡ‹, Π° Ρ‚Π°ΠΊΠΆΠ΅ Π² Ρ†Π΅Π½Ρ‚Ρ€Π΅, Π³Π΄Π΅ ΠΏΡƒΡ‡ΠΎΠΊ ослабляСтся ΠΈΠ·-Π·Π° высокой плотности ΠΏΠ»Π°Π·ΠΌΡ‹. ЭкспСримСнты ΠΏΠΎ ΠΎΠΏΡ‚ΠΈΠΌΠΈΠ·Π°Ρ†ΠΈΠΈ ΠΏΠΎΠΊΠ°Π·Π°Π»ΠΈ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ формирования ΠΈΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° Π² Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ Ρ‚ΠΎΠΊΠ° 40…800 мкА

    A dual heavy ion beam probe diagnostic on the TJ-II stellarator

    Get PDF
    The aim of the report is to show the development of HIBP diagnostics on the TJ-II stellarator and, as a result, the expansion of the range of plasma parameters measurements. The first Heavy Ion Beam Probe (HIBP-1) diagnostic is being used on TJ-II stellarator since 2000. It has been shown significant progress in the measurements of plasma profiles and oscillations. The second HIBP-2 system was installed on TJ-II in 2012. Dual HIBP system, consisting of two identical HIBP-1 and HIBP-2 located ΒΌ torus apart, provides the measurement of the long-range correlations of plasma parameters in the full plasma column. Low noise high gain (10⁷ V/A) preamplifiers with 1 Hz bandwidth sampling is used. They allow to study broadband turbulence and quasi-coherent modes like geodesic acoustic modes, Alfven eigenmodes, suprathermal electron induced modes, etc. New capabilities of the dual HIBP diagnostic in plasma potential and density investigations were demonstrated on TJ-II stellarator in the measurements of the correlation between fluctuations in different poloidal and toroidal locations: on the same field line, on the same magnetic surface or on different magnetic surfaces at different points, separated toroidally and/or poloidally.На стСлараторі TJ-II створСна ΠΏΠΎΠ΄Π²Ρ–ΠΉΠ½Π° систСма зондування ΠΏΠ»Π°Π·ΠΌΠΈ ΠΏΡƒΡ‡ΠΊΠΎΠΌ Π²Π°ΠΆΠΊΠΈΡ… Ρ–ΠΎΠ½Ρ–Π² (Π—ΠŸΠŸΠ’Π†). БистСма ΡΠΊΠ»Π°Π΄Π°Ρ”Ρ‚ΡŒΡΡ Π· Π΄Π²ΠΎΡ… Ρ–Π΄Π΅Π½Ρ‚ΠΈΡ‡Π½ΠΈΡ… комплСксів, Ρ€ΠΎΠ·Ρ‚Π°ΡˆΠΎΠ²Π°Π½ΠΈΡ… Π½Π° відстані ΒΌ Ρ‚ΠΎΡ€Π°. ΠŸΠ΅Ρ€ΡˆΠΈΠΉ діагностичний комплСкс ΠΏΠΎΡ‡Π°Π² діяти Π² 2000 Ρ€ΠΎΡ†Ρ–. Π”Ρ€ΡƒΠ³ΠΈΠΉ комплСкс Π±ΡƒΠ² встановлСний Π² 2012 Ρ€ΠΎΡ†Ρ–. Використання ΠΏΡ–Π΄ΡΠΈΠ»ΡŽΠ²Π°Ρ‡Ρ–Π² Π΄Π΅Ρ‚Π΅ΠΊΡ‚ΠΎΡ€Π½ΠΈΡ… сигналів Π· низьким Ρ€Ρ–Π²Π½Π΅ΠΌ ΡˆΡƒΠΌΡƒ (10⁷ Π’/A) Π· ΠΏΡ€ΠΎΠΏΡƒΡΠΊΠ½ΠΎΡŽ Π·Π΄Π°Ρ‚Π½Ρ–ΡΡ‚ΡŽ 1 ΠœΠ“Ρ† дозволяє Π²ΠΈΠ²Ρ‡Π°Ρ‚ΠΈ ΡˆΠΈΡ€ΠΎΠΊΠΎΡΠΌΡƒΠ³ΠΎΠ²Ρƒ Ρ‚ΡƒΡ€Π±ΡƒΠ»Π΅Π½Ρ‚Π½Ρ–ΡΡ‚ΡŒ Ρ‚Π° ΠΊΠ²Π°Π·Ρ–ΠΊΠΎΠ³Π΅Ρ€Π΅Π½Ρ‚Π½Ρ– Ρ€Π΅ΠΆΠΈΠΌΠΈ, Ρ‚Π°ΠΊΡ– як Π³Π΅ΠΎΠ΄Π΅Π·ΠΈΡ‡Π½Ρ– акустичні ΠΌΠΎΠ΄ΠΈ; Π°Π»ΡŒΡ„Π²Π΅Π½Ρ–Π²ΡΡŒΠΊΡ– ΠΌΠΎΠ΄ΠΈ; ΡΡƒΠΏΠ΅Ρ€Ρ‚Π΅Ρ€ΠΌΠ°Π»ΡŒΠ½Ρ– ΠΌΠΎΠ΄ΠΈ, які Π·Π±ΡƒΡ€ΡŽΡŽΡ‚ΡŒΡΡ швидкими Π΅Π»Π΅ΠΊΡ‚Ρ€ΠΎΠ½Π°ΠΌΠΈ, Ρ‚ΠΎΡ‰ΠΎ. Нові моТливості ΠΏΠΎΠ΄Π²Ρ–ΠΉΠ½ΠΎΡ— систСми Π±ΡƒΠ»ΠΈ продСмонстровані ΠΏΡ€ΠΈ Π²ΠΈΠΌΡ–Ρ€ΡŽΠ²Π°Π½Π½ΡΡ… Π΄Π°Π»Π΅ΠΊΠΈΡ… корСляцій ΠΌΡ–ΠΆ флуктуаціями Π² Ρ€Ρ–Π·Π½ΠΈΡ… ΠΏΠΎΠ»ΠΎΡ—Π΄Π°Π»ΡŒΠ½ΠΈΡ… Ρ‚Π° Ρ‚ΠΎΡ€ΠΎΡ—Π΄Π°Π»ΡŒΠ½ΠΈΡ… місцях: Π½Π° ΠΎΠ΄Π½Ρ–ΠΉ Π»Ρ–Π½Ρ–Ρ— ΠΌΠ°Π³Π½Ρ–Ρ‚Π½ΠΎΠ³ΠΎ поля, Π½Π° ΠΎΠ΄Π½Ρ–ΠΉ Π°Π±ΠΎ Π½Π° Ρ€Ρ–Π·Π½ΠΈΡ… ΠΌΠ°Π³Π½Ρ–Ρ‚Π½ΠΈΡ… повСрхнях Ρƒ Ρ€Ρ–Π·Π½ΠΈΡ… Ρ‚ΠΎΡ‡ΠΊΠ°Ρ…, Ρ€ΠΎΠ·Ρ‚Π°ΡˆΠΎΠ²Π°Π½ΠΈΡ… Ρ‚ΠΎΡ€ΠΎΡ—Π΄Π°Π»ΡŒΠ½ΠΎ Ρ‚Π°/Π°Π±ΠΎ ΠΏΠΎΠ»ΠΎΡ—Π΄Π°Π»ΡŒΠ½ΠΎ.На стСллараторС TJ-II создана двойная систСма зондирования ΠΏΠ»Π°Π·ΠΌΡ‹ ΠΏΡƒΡ‡ΠΊΠΎΠΌ тяТСлых ΠΈΠΎΠ½ΠΎΠ² (Π—ΠŸΠŸΠ’Π˜). БистСма состоит ΠΈΠ· Π΄Π²ΡƒΡ… ΠΈΠ΄Π΅Π½Ρ‚ΠΈΡ‡Π½Ρ‹Ρ… комплСксов, располоТСнных Π½Π° расстоянии ΒΌ Ρ‚ΠΎΡ€Π°. ΠŸΠ΅Ρ€Π²Ρ‹ΠΉ диагностичСский комплСкс Π½Π°Ρ‡Π°Π» Π΄Π΅ΠΉΡΡ‚Π²ΠΎΠ²Π°Ρ‚ΡŒ Π² 2000 Π³ΠΎΠ΄Ρƒ. Π’Ρ‚ΠΎΡ€ΠΎΠΉ комплСкс Π±Ρ‹Π» установлСн Π² 2012 Π³ΠΎΠ΄Ρƒ. ИспользованиС усилитСлСй Π΄Π΅Ρ‚Π΅ΠΊΡ‚ΠΎΡ€Π½Ρ‹Ρ… сигналов с Π½ΠΈΠ·ΠΊΠΈΠΌ ΡƒΡ€ΠΎΠ²Π½Π΅ΠΌ ΡˆΡƒΠΌΠ° (10⁷ Π’/A) ΠΈ полосой пропускания 1 ΠœΠ“Ρ† позволяСт ΠΈΠ·ΡƒΡ‡Π°Ρ‚ΡŒ ΡˆΠΈΡ€ΠΎΠΊΠΎΠΏΠΎΠ»ΠΎΡΠ½ΡƒΡŽ ΡƒΡ€Π±ΡƒΠ»Π΅Π½Ρ‚Π½ΠΎΡΡ‚ΡŒ ΠΈ ΠΊΠ²Π°Π·ΠΈΠΊΠΎΠ³Π΅Ρ€Π΅Π½Ρ‚Π½Ρ‹Π΅ ΠΌΠΎΠ΄Ρ‹, Ρ‚Π°ΠΊΠΈΠ΅ ΠΊΠ°ΠΊ гСодСзичСскиС акустичСскиС ΠΌΠΎΠ΄Ρ‹; Π°Π»ΡŒΡ„Π²Π΅Π½ΠΎΠ²ΡΠΊΠΈΠ΅ собствСнныС ΠΌΠΎΠ΄Ρ‹; ΠΌΠΎΠ΄Ρ‹, ΠΈΠ½Π΄ΡƒΡ†ΠΈΡ€ΠΎΠ²Π°Π½Π½Ρ‹Π΅ Π½Π°Π΄Ρ‚Π΅ΠΏΠ»ΠΎΠ²Ρ‹ΠΌΠΈ элСктронами ΠΈ Ρ‚.Π΄. НовыС возмоТности Π΄Π²ΠΎΠΉΠ½ΠΎΠΉ систСмы Π±Ρ‹Π»ΠΈ продСмонстрированы ΠΏΡ€ΠΈ измСрСниях Π΄Π°Π»ΡŒΠ½ΠΈΡ… коррСляций ΠΌΠ΅ΠΆΠ΄Ρƒ флуктуациями, ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½Π½Ρ‹ΠΌΠΈ Π² Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… ΠΏΠΎΠ»ΠΎΠΈΠ΄Π°Π»ΡŒΠ½ΠΈΡ… ΠΈ Ρ‚ΠΎΡ€ΠΎΠΈΠ΄Π°Π»ΡŒΠ½Ρ‹Ρ… полоТСниях: Π½Π° ΠΎΠ΄Π½ΠΎΠΉ ΠΈΠ»ΠΈ Π½Π° Ρ€Π°Π·Π½Ρ‹Ρ… ΠΌΠ°Π³Π½ΠΈΡ‚Π½Ρ‹Ρ… повСрхностях, Π² Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… Ρ‚ΠΎΡ‡ΠΊΠ°Ρ…, смСщСнных Ρ‚ΠΎΡ€ΠΎΠΈΠ΄Π°Π»ΡŒΠ½ΠΎ ΠΈ/ΠΈΠ»ΠΈ полоидально
    corecore