24 research outputs found

    Performance of clear vacuum-formed thermoplastic retainers depending on retention protocol: a systematic review

    Get PDF
    We aimed at comparing the performance of vacuum-formed thermoplastic retainers (VFR) worn either full-time or part-time, in maintaining orthodontic treatment results in terms of tooth alignment, arch form and occlusion. We reviewed randomized and prospective controlled clinical trials comparing VFR wearing protocols and searched databases, without restrictions, for published and unpublished literature. The risk of bias was assessed using the Cochrane Risk of Bias tool and the overall level of certainty in the evidence following ADA methodology. 184 studies were initially identified and reduced to the 3 randomized controlled trials included in the systematic review by means of specific criteria. One study followed patients 1 year into retention, and the other two for 6 months. Little's Irregularity Index, intermolar and intercanine width, arch length, overjet and PAR score did not differ significantly between the patients wearing their retainers part time or full time. We observed a slight increase in the overbite in the part-time group in only one trial. With a moderate level of certainty, we found that during the observation period, full-time VFR wear is not superior to part-time, bearing in mind the potential implications for health burden, retainer longevity and cost-effectiveness, as well as patient satisfaction and compliance

    Torque efficiency of square and rectangular archwires into 0.018 and 0.022 in. conventional brackets

    No full text
    Background: The aim of this study was to compare the torque efficacy of square and rectangular wires in 0.018- and 0.022-in. conventionally ligated brackets. Methods: Brackets of the same prescription were evaluated in both slot dimensions. Identical acrylic resin models of the maxilla were bonded with the brackets and mounted on the Orthodontic Measurement and Simulation System. Ten 0.018 × 0.018 in., 0.018 × 0.022 in., and 0.018 × 0.025 in. stainless steel wires were evaluated in the 0.018-in. brackets and ten 0.019 × 0.019 in., 0.019 × 0.025 in., and 0.019 × 0.026 in. stainless steel wires were evaluated in the 0.022-in. brackets. A 15° buccal root torque was gradually applied to the right central incisor bracket, and the moments were recorded at this position. One-way ANOVA was applied for both bracket slot sizes along with post hoc analysis for the various archwire sizes. Results: The mean measured moments varied between 10.78 and 30.60 Nmm among the assessed wire-and-bracket combinations. Both square and rectangular archwires in the 0.018-in. bracket system exerted statistically significantly higher moments in comparison with their counterparts in the 0.022-in. bracket system. Rectangular archwires exerted statistically significantly higher moments than square archwires, both for the 0.018- and the 0.022-in. bracket system. Conclusions: Rectangular archwires seem to be more efficient in torque exertion, especially in 0.018-in. brackets. © 2016 Papageorgiou et al

    Immunohistochemical evaluation of the mTOR pathway in intra-oral minor salivary gland neoplasms

    No full text
    Objectives: The aim of this study was to investigate the expression of upstream and downstream molecules of the oncogenic mTOR signaling pathway in intra-oral minor salivary gland tumors (SGTs). Materials and Methods: Tissue samples consisted of 39 malignant and 13 benign minor SGTs, and 8 controls of normal minor salivary glands (NMSG). An immunohistochemical analysis for phosphorylated Akt, 4EBP1 and S6 (total and phosphorylated), and eIF4E was performed. Results: Expression of pAkt and 4EBP1 was observed in all SGTs and in most NMSG. p4EBP1 was detected in almost all SGT cases, NMSG being negative. S6 immunoreactivity was observed in 37.5% of NMSG, 92.3% of benign and 100% of malignant SGTs, while pS6 expression was observed in 77% of benign and 95% of malignant SGTs, but not in NMSG. Finally, eIF4E was expressed in 12.5% of NMSG, 69.2% of benign, and 76.9% of malignant tumors. All molecules studied had statistically significantly lower expression in NMSG compared with SGTs. Moreover, malignant neoplasms received higher scores compared with benign tumors for all molecules with the exception of eIF4E. Conclusion: The mTOR signaling pathway is activated in SGTs, especially in malignancies. Therefore, the possible therapeutic role of targeting the mTOR pathway by rapamycin analogs in SGTs needs further investigation. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Lt

    Gingival thickness assessment at the mandibular incisors with four methods: A cross-sectional study.

    No full text
    BACKGROUND This study was conducted to determine accuracy, precision and repeatability of four different methods for assessing gingival thickness METHODS: This cross-sectional study evaluated gingival thickness on 200 consecutively included orthodontic patients. Gingival thickness was assessed at both central mandibular incisors with: 1) transgingival probing with a standard periodontal probe, 2) transgingival probing with a stainless-steel acupuncture needle, 3) ultrasound, and 4) a color-coded periodontal probe. Intra-examiner reproducibility and method error were also evaluated. RESULTS Transgingival measurements with the standard periodontal probe were found to be more accurate than those with the acupuncture needle, after method error assessment. Acupuncture needle and ultrasound device yielded higher values than the probe. Expected differences between the two methods were 22% more for the mandibular left central incisor (95% confidence interval (CI) = 11% to 32%) and 26% more (95% CI = 13% to 39%) for the mandibular right central incisor when measured with the needle. Ultrasound measurements exceeded probe measurements on average by 0.16 mm at mandibular left central incisor (95% CI = 0.14 to 0.18) and by 0.11 mm for mandibular right central incisor (95% CI = 0.08 to 0.13). Intraclass correlation coefficient concluded good agreement for the color-coded periodontal probe (0.624). CONCLUSIONS Within the inherent limit of the uncertainty about the true value of gingival thickness, the present results demonstrate the differences between the tested methods, as far as accuracy and reproducibility are concerned. Based on the reproducibility, the transgingival probing with the periodontal probe as well as the ultrasound determination, seem to present an adequate choice for every day practice

    Reporting quality of randomised controlled trials published in prosthodontic and implantology journals

    Get PDF
    The purpose of this study was to examine the reporting quality of randomised controlled trials (RCTs) published in prosthodontic and implantology journals. Thirty issues of nine journals in prosthodontics and implant dentistry were searched for RCTs, covering the years 2005-2012: The Journal of Prosthetic Dentistry, Journal of Oral Rehabilitation, The International Journal of Prosthodontics, The International Journal of Periodontics & Restorative Dentistry, Clinical Oral Implants Research, Clinical Implant Dentistry & Related Research, The International Journal of Oral & Maxillofacial Implants, Implant Dentistry and Journal of Dentistry. The reporting quality was assessed using a modified Consolidated Standards of Reporting Trials (CONSORT) statement checklist. Data were analysed using descriptive statistics followed by univariable and multivariable examination of statistical associations (α = 0·05). A total of 147 RCTs were identified with a mean CONSORT score of 69·4 (s.d. = 9·7). Significant differences were found among journals with the Journal of Oral Rehabilitation achieving the highest score (80·6, s.d. = 5·5) followed by Clinical Oral Implants Research (73·7, s.d. = 8·3). Involvement of a statistician/methodologist was significantly associated with increased CONSORT scores. Overall, the reporting quality of RCTs in major prosthodontic and implantology journals requires improvement. This is of paramount importance considering that optimal reporting of RCTs is an important prerequisite for clinical decision-making

    BPA qualtitative and quantitative assessment associated with orthodontic bonding in vivo

    No full text
    Objective To assess the in vivo amount of BPA released from a visible light-cured orthodontic adhesive, immediately after bracket bonding. Methods 20 orthodontic patients were recruited after obtaining informed consent. All patients received 24 orthodontic brackets in both dental arches. In Group A (11 patients), 25 ml of tap water were used for mouth rinsing, whereas in Group B (9 patients) a simulated mouth rinse formulation was used: a mixture of 20 ml de-ionized water plus 5 ml absolute ethanol. Rinsing solutions were collected before, immediately after placing the orthodontic appliances and after washing out the oral cavity and were then stored in glass tubes. Rinsing was performed in a single phase for 60 s with the entire volume of each liquid. The BPA analysis was performed by gas chromatography-mass spectrometry. Results An increase in BPA concentration immediately after the 1st post-bonding rinse was observed, for both rinsing media, which was reduced after the 2nd post-bonding rinse. Water exhibited higher levels of BPA concentration than water/ethanol after 1st and 2nd post-bonding rinses. Two-way mixed Repeated Measures ANOVA showed that the primary null hypothesis declaring mean BPA concentration to be equal across rinsing medium and rinsing status was rejected (p-value <0.001). The main effects of the rinsing medium and status, as well as their interaction were found to be statistically significant (p-values 0.048, <0.001 and 0.011 respectively). Significance A significant pattern of increase of BPA concentration, followed by a decrease that reached the initial values was observed. The amount of BPA was relatively low and far below the reference limits of tolerable daily intake. © 2015 Published by Elsevier Ltd on behalf of Academy of Dental Materials. All rights reserved

    Ιntra-species grafting induces epigenetic and metabolic changes accompanied by alterations in fruit size and shape of Cucurbita pepo L.

    No full text
    To further understand the impact of grafting on fruit characteristics and to comprehend the mechanisms involved in graft-induced changes we studied homo- and hetero- grafted Cucurbita pepo cultivars (cv.) that vary in fruit size and shape. C. pepo cv. ‘Munchkin’ and cv. ‘Big Moose’ as well as cv. ‘Round green’ and cv. ‘Princess’ were homo-grafted and reciprocally hetero-grafted. The results show significant changes in fruit size when ‘Big Moose’ was grafted onto ‘Munchkin’ rootstocks in comparison to homo-grafted controls. Statistically significant changes were also observed in fruit shape when cv. ‘Princess’ was grafted on cv. ‘Round green’. This is the first report of such phenotypic changes after intra-species/inter-cultivar grafting in Cucurbitaceae. Additionally, we found significant changes in (i) secondary metabolite profile, (ii) global DNA methylation pattern and (iii) miRNA expression patterns in grafted scions and (iv) DNA methylation on graft-induced phenotypic changes in grafted plants. Our results contribute to further understanding graft-induced effects on fruit morphology in intra-species grafting. Furthermore, our results pave the way for understanding the role of phenolic metabolites and epigenetic molecular mechanisms on the phenotypic changes recorded
    corecore