278 research outputs found

    Interrelations between dry bulk forward freight agreements and the dry bulk spot market

    Get PDF

    Determination of longitudinal bunch shape by means of coherent Smith-Purcell radiation

    Get PDF
    Coherent enhancement of the Smith-Purcell radiation produced from the interaction of a 1.8 MeV electron beam with a grating has been observed. The emitted radiation has been measured at angles in the 40° to 120° range, which correspond to wavelengths from 0.65 to 4 mm, approximately. The radiated power was 320 mW at 90°. Its angular distribution agrees well with the description of the process in terms of induced surface currents and has been used to infer the longitudinal profile of the electron bunch. It is concluded that the bunch has an approximately triangular profile, with 85% of the bunch particles contained within 14 ps. The possibilities of the technique as a bunch-shape diagnostic tool are also discussed

    Determination of longitudinal bunch shape by means of coherent Smith-Purcell radiation

    Get PDF
    Coherent enhancement of the Smith-Purcell radiation produced from the interaction of a 1.8 MeV electron beam with a grating has been observed. The emitted radiation has been measured at angles in the 40° to 120° range, which correspond to wavelengths from 0.65 to 4 mm, approximately. The radiated power was 320 mW at 90°. Its angular distribution agrees well with the description of the process in terms of induced surface currents and has been used to infer the longitudinal profile of the electron bunch. It is concluded that the bunch has an approximately triangular profile, with 85% of the bunch particles contained within 14 ps. The possibilities of the technique as a bunch-shape diagnostic tool are also discussed. © 2002 The American Physical Society

    A beta-alpha coincidence counting system for measurement of trace quantities of 238U and 232Th in aqueous samples at the Sudbury Neutrino Observatory

    Get PDF
    The Sudbury Neutrino Observatory experiment was built to measure the total flux of 8B solar neutrinos via the neutral current disintegration deuterium nuclei. This process can be mimicked by daughter isotopes of 232Th and 238U which can photo-disintegrate the deuterium nucleus. Measurement of the concentration of such radioisotopes in the heavy water was critical to the success of the experiment. A radium assay technique using Hydrous Titanium Oxide coated filters was developed for this purpose and it was used in conjunction with a delayed beta-alpha coincidence counting system. The design, calibration and operation of this counting system are described in this paper. The counting efficiency for 232Th (224Ra) and 238U (226Ra) were measured to be 50 +/- 5% and 62 +/- 7

    Reconstruction of longitudinal electrons bunch profiles at FACET, SLAC

    No full text
    Work supported by funding from Universite Paris Sud, program "Attractivite" and by the ANR under contract ANR-12-JS05-0003-01 - http://accelconf.web.cern.ch/AccelConf/IPAC2014/papers/thpme093.pdfInternational audienceThe E-203 collaboration is testing a device on FACET at SLAC to measure the longitudinal profile of electron bunches using Smith-Purcell radiation [1]. At FACET the electron bunches have an energy of 20 GeV and a duration of a few hundred femtoseconds [2]. Smith-Purcell radiation is emitted when a charged particle passes close to the sur- face of a metallic grating. We have studied the stability of the measurement from pulse to pulse and the resolution of the measure depending on the number of gratings used

    Four methods for determining the composition of trace radioactive surface contamination of low-radioactivity metal

    Full text link
    Four methods for determining the composition of low-level uranium- and thorium-chain surface contamination are presented. One method is the observation of Cherenkov light production in water. In two additional methods a position-sensitive proportional counter surrounding the surface is used to make both a measurement of the energy spectrum of alpha particle emissions and also coincidence measurements to derive the thorium-chain content based on the presence of short-lived isotopes in that decay chain. The fourth method is a radiochemical technique in which the surface is eluted with a weak acid, the eluate is concentrated, added to liquid scintillator and assayed by recording beta-alpha coincidences. These methods were used to characterize two `hotspots' on the outer surface of one of the He-3 proportional counters in the Neutral Current Detection array of the Sudbury Neutrino Observatory experiment. The methods have similar sensitivities, of order tens of ng, to both thorium- and uranium-chain contamination.Comment: 22 pages, 19 figure

    High sensitivity measurement of 224Ra and 226Ra in water with an improved hydrous titanium oxide technique at the Sudbury Neutrino Observatory

    Full text link
    The existing hydrous titanium oxide (HTiO) technique for the measurement of 224Ra and 226Ra in the water at the Sudbury Neutrino Observatory (SNO) has been changed to make it faster and less sensitive to trace impurities in the HTiO eluate. Using HTiO-loaded filters followed by cation exchange adsorption and HTiO co-precipitation, Ra isotopes from 200-450 tonnes of heavy water can be extracted and concentrated into a single sample of a few millilitres with a total chemical efficiency of 50%. Combined with beta-alpha coincidence counting, this method is capable of measuring 2.0x10^3 uBq/kg of 224Ra and 3.7x10^3 uBq/kg of 226Ra from the 232Th and 238U decay chains, respectively, for a 275 tonne D2O assay, which are equivalent to 5x10^16 g Th/g and 3x10^16 g U/g in heavy water.Comment: 8 Pages, 2 figures and 2 table

    Spectra of Coherent Smith-Purcell Radiation Observed from Short Electron Bunches: Numerical and Experimental Studies

    No full text
    MOPWA056 - ISBN978-3-95450-122-9International audienceThere is a significant interest in the development of compact particle accelerators within research areas including X-ray and THz (T-ray) sources of radiation, particle physics and medical sciences. To support the progress in these areas, non-invasive, electron beam diagnostics that are capable of measuring a single femtosecond electron bunch are required. At the current stage such beam diagnostics for femtosecond-long electron bunches are still not available. The goal of the work presented is to understand the spectral characteristics of coherent Smith-Purcell radiation to enable its quick and reliable interpretation including the longitudinal profile reconstruction of electron bunches. The research presented comprises results from numerical modelling and experimental studies. Using the numerical data, we discuss the radiated spectra dependence on the electron bunch profile and analyse the results. We also discuss the experimental data and compare it with theoretical predictions

    Maximal Spontaneous Photon Emission and Energy Loss from Free Electrons

    Full text link
    Free electron radiation such as Cerenkov, Smith--Purcell, and transition radiation can be greatly affected by structured optical environments, as has been demonstrated in a variety of polaritonic, photonic-crystal, and metamaterial systems. However, the amount of radiation that can ultimately be extracted from free electrons near an arbitrary material structure has remained elusive. Here we derive a fundamental upper limit to the spontaneous photon emission and energy loss of free electrons, regardless of geometry, which illuminates the effects of material properties and electron velocities. We obtain experimental evidence for our theory with quantitative measurements of Smith--Purcell radiation. Our framework allows us to make two predictions. One is a new regime of radiation operation---at subwavelength separations, slower (nonrelativistic) electrons can achieve stronger radiation than fast (relativistic) electrons. The second is a divergence of the emission probability in the limit of lossless materials. We further reveal that such divergences can be approached by coupling free electrons to photonic bound states in the continuum (BICs). Our findings suggest that compact and efficient free-electron radiation sources from microwaves to the soft X-ray regime may be achievable without requiring ultrahigh accelerating voltages.Comment: 7 pages, 4 figure

    Measurement of 222Rn dissolved in water at the Sudbury Neutrino Observatory

    Full text link
    The technique used at the Sudbury Neutrino Observatory (SNO) to measure the concentration of 222Rn in water is described. Water from the SNO detector is passed through a vacuum degasser (in the light water system) or a membrane contact degasser (in the heavy water system) where dissolved gases, including radon, are liberated. The degasser is connected to a vacuum system which collects the radon on a cold trap and removes most other gases, such as water vapor and nitrogen. After roughly 0.5 tonnes of H2O or 6 tonnes of D2O have been sampled, the accumulated radon is transferred to a Lucas cell. The cell is mounted on a photomultiplier tube which detects the alpha particles from the decay of 222Rn and its daughters. The overall degassing and concentration efficiency is about 38% and the single-alpha counting efficiency is approximately 75%. The sensitivity of the radon assay system for D2O is equivalent to ~3 E(-15) g U/g water. The radon concentration in both the H2O and D2O is sufficiently low that the rate of background events from U-chain elements is a small fraction of the interaction rate of solar neutrinos by the neutral current reaction.Comment: 14 pages, 6 figures; v2 has very minor change
    corecore