24 research outputs found

    Use of the iliac-outlet and iliac-inlet combined views in percutaneous posterior column retrograde screw fixation

    Get PDF
    Posterior column fractures are common acetabular injuries. Although displaced fractures require open reduction and fixation, undisplaced patterns may benefit from percutaneous screw fixation. The combination of iliac oblique with inlet and outlet views offers an intuitive and panoramic rendering of the bony corridor into the posterior column; lateral cross table view completes the sequence of fluoroscopic projections. Herein we describe the use of outlet/inlet iliac views and a detailed procedure for percutaneous retrograde posterior column screw fixation

    A case report of femoral head fracture with osteochondral lesion treated by osteosynthesis and biomimetic scaffold: 2-year clinical and radiological follow-up

    Get PDF
    The aim of the present study was to present clinical and radiological outcome of a hip fracture-dislocation of the femoral head treated with biomimetic osteochondral scaffold. An 18-year-old male was admitted to the hospital after a motorcycle-accident. He presented with an obturator hip dislocation with a type IVA femoral head fracture according to Brumback classification system. The patient underwent surgery 5 days after accident. The largest osteochondral fragment was reduced and stabilized with 2 screws, and the small fragments were removed. The residual osteochondral area was replaced by a biomimetic nanostructured osteochondral scaffold. At 1-year follow-up the patient did not complain of hip pain and could walk without limp. At 2-year follow-up he was able to run with no pain and he returned to practice sports. Repeated radiographs and magnetic resonance imaging studies of the hip showed no signs of osteoarthritis or evidence of avascular necrosis. A hyaline-like signal on the surface of the scaffold was observed with restoration of the articular surface and progressive decrease of the subchondral edema. The results of the present study showed that the biomimetic nanostructured osteochondral scaffold could be a promising and safe option for the treatment of traumatic osteochondral lesions of the femoral head. Study Design: Case report

    Implant retention with serial debridement and use of antibiotic-loaded calcium sulfate beads in acute fracture-related infection (FRI) after pelvic ring or acetabular fractures: A retrospective case series of 7 cases

    Get PDF
    Background: The development of a pelvic wound infection in the presence of hardware after open reduction and internal fixation presents a clinical dilemma and there is little literature to aid in decision-making. The purpose of this study was to describe the possibility of debridement, antibiotic pearls and retention of the implant (DAPRI) procedure to eradicate the infection. Methods: Tumor-like debridement, antibiotic pearls and retention of the implant (DAPRI) aimed to remove the biofilm allowing a higher and prolonged local antibiotic concentration by using calcium sulfate antibiotic-added beads. Wound status, radiological signs of bone healing, gait and functional activity of the patient were evaluated. Results: Seven patients underwent this technique. The mean follow up time was nine months (range: 6 -16 months). Complete wound healing was achieved in all the patients with no major complications. Average time of bony union was 4.3 months (range: 3-6 months) with no need for implant removal. Conclusion: The DAPRI technique might represent a safe and more conservative treatment for management of early fracture-related infections (FRI) of the pelvis and acetabulum

    Pseudo-aneurysm of a lumbar artery after flexion-distraction injury of the thoraco-lumbar spine and surgical realignment: rupture treated by endovascular embolization

    No full text
    A unique case of pseudo-aneurysm of a lumbar artery after injury of the thoracolumbar spine was presented. Injury of a lumbar artery represents a potential cause of massive, life-threatening, retroperitoneal bleeding. It may be associated with lesions of the abdomen, lower limbs, pelvic bones, and spinal column. Fracture of a transverse process may be responsible for direct laceration of a lumbar artery, but formation of a pseudo-aneurysm is an uncommon event. The diagnosis is difficult and often delayed. The treatment of choice is endovascular embolization. In a patient who had a posttraumatic severe thoracolumbar vertebral dislocation with complete spinal cord lesion after road accident, we performed surgical reduction and stabilization via posterior approach. After 7 days, he developed a progressive anemia due to retroperitoneal hemorrhage and formation of a pseudo-aneurysm of the lumbar artery at L1 level. Endovascular embolization achieved resolution of the pseudo-aneurysm, regression of the hematoma and progressive recovery of the patient during a period of 6 months. Pseudo-aneurysm of a lumbar artery has never previously been described in association with flexion-distraction type vertebral fracture, in which the spinal column is subjected to greater, shear-type, forces. Stretching of the arterial wall due to the traumatic dislocation of the spine and subsequent surgical realignment may be considered as the mechanism of formation and rupture of the pseudo-aneurysm. Dangerous bleeding in the retroperitoneal space and in the operative field can be effectively managed by endovascular intervention

    Use of patient-specific guides and 3D model in scapula osteotomy for symptomatic malunion

    Get PDF
    Abstract Background Scapular osteotomy for malunion can lead to resolution of pain and functional improvement in scapula fracture sequelae. Understanding three-dimensional bone morphology and analysing post-traumatic deformity is the main step of planning and the key to success of the procedure. 3D models and patient-specific guides are a growing technology to enhance accuracy of planning and to assist during surgery. Case presentation We report the case of a 50 years old male, complaining of pain and limited function after a malunited scapular body fracture. Clinical assessment showed a severe impairment of shoulder function with active and passive forward flexion limited to 80°, absent external rotation, and internal rotation limited to the buttock. X-rays and CT scan showed an excessive lateral border offset of 53 mm and complete displacement of the glenoid segment anteriorly and medially to the scapular body, with impingement between the lateral most prominent scapular bone spur and humeral shaft. Glenopolar angle was 19°, scapular body angulation on the sagittal plane was 12°. Corrective osteotomy was planned on a virtual interactive rendering and on 3D printed models. Patient-specific guides were developed to perform a body-spine osteotomy with removal of a bone wedge, and a glenoid-spine osteotomy; a patient-specific wedge spacer was used to hold the reduction during plate fixation. Follow-up up to 12 months after surgery demonstrated improvement in scapula anatomy, shoulder girdle function, and patient-reported outcomes. Conclusions For the first time in scapula malunion surgery, patient-specific osteotomy guides were succesfully used during surgery to perform osteotomies and to assist in reduction maneuvers

    Ventriculoatrial shunt in adults. A case series, with emphasis on atrial catheter migration

    No full text
    Objectives: Few studies have described retrograde migration of the atrial catheter tip in ventriculoatrial shunt to treat adult hydrocephalus. Methods: We placed ventriculoatrial shunts in 25 selected adult patients with a previous complicated abdominal surgery or concurrent bowel disease and in patients with persistent symptoms after a ventriculoperitoneal, potentially due to conflicting internal abdominal pressure. Clinical and radiological follow-ups were performed at least 18 months postoperatively. Results: No mortality or early or late infection occurred in the series of patients. At the long-term clinical and radiological follow-up (mean 4.5 years), eight patients died due to causes unrelated to shunt surgery. All other patients were able to live independently but some experienced neurological decline related to their neurodegenerative disease. In five patients (20%), atrial catheter migration was detected on a control chest x-ray; in four patients, it was associated with worsening of their clinical condition. These patients underwent surgical substitution of the atrial catheter. The remaining asymptomatic patient was managed conservatively. Conclusions: The ventriculoatrial shunt was a safe, effective procedure for treating hydrocephalus in adult patients. Retrograde migration of the atrial catheter tip in symptomatic patients required surgical substitution of the atrial catheter. Keywords: Cardiac catheter, Complication, Endovascular procedure, Hydrocephalus, Migration, Normal-pressure, Shunt, Surgical procedur

    Management of distal femoral fractures with metaphyseal and articular comminution (AO/OTA 33C) using nail and plate fixation: a technical note and case series of 14 patients

    No full text
    PurposeTo describe the surgical technique and the outcome of a case series of comminuted intra-articular distal femur fractures (AO/OTA 33C) treated with a nail-plate combination (NPC) implant.MethodsWe retrospectively analyzed a case series of 14 patients with comminuted intra-articular distal femur fractures (DFF) treated with an intramedullary retrograde nail in combination with a lateral low-contact condylar locking plate, in a period between June 2020 and January 2023 at a Level 1 trauma center. Baseline demographic and clinical data were recorded. Time to bone healing, function using Schatzker Lambert Score, and complications were documented.ResultsFourteen patients, 8 males and 6 females, with a total of 15 NPC implants, were included in this study. Eight out of 14 patients had open fractures, all with a Gustilo Anderson type IIIA exposure. The mean age was 48.5 +/- 18.05 years. The median follow-up was 392 days, with only one patient lost to follow-up. 11 out of 15 implants achieved complete radiographic consolidation during follow-up, at a mean of 5.40 +/- 1.07 months. At the 12-month follow-up, all patients could fully bear weight painlessly or with mild pain. Schatzker Lambert Score was excellent for 4 patients, good for 2 patients, fair for 5 patients, and failure for 2 patients. The main postoperative complications were rigidity (3 cases), limb shortening (2 cases), and septic non-union (1 case).ConclusionThis study suggests that the nail-plate combination (NPC) may provide a more effective surgical technique for addressing the challenges associated with comminuted intra-articular distal femur fractures (AO/OTA 33C)

    [Pregnancy and heart disease: the role of the Pregnancy Heart Team]

    No full text
    : A significant risk of maternal and fetal morbidity and mortality has been shown to be associated with congenital heart disease or heart disease occurring during pregnancy. Given the increasing number of patients with corrected congenital heart disease who reach fertile age and the more and more common advanced maternal age associated with preexisting or intercurrent comorbidities, a higher incidence of cardiac complications in pregnancy has been reported in the last decades. Improvement in maternal and neonatal outcomes is influenced by a multidisciplinary strategy. The purpose of this review is to assess the role of the Pregnancy Heart Team which should ensure careful pre-pregnancy counseling, pregnancy monitoring, and delivery planning for both congenital heart disease and other cardiac or metabolic disorders
    corecore