1,912 research outputs found

    Apollo experience report: Mission evaluation team postflight documentation

    Get PDF
    The various postflight reports prepared by the mission evaluation team, including the final mission evaluation report, report supplements, anomaly reports, and the 5-day mission report, are described. The procedures for preparing each report from the inputs of the various disciplines are explained, and the general method of reporting postflight results is discussed. Recommendations for postflight documentation in future space programs are included. The official requirements for postflight documentation and a typical example of an anomaly report are provided as appendixes

    Development of user guidelines for ECAS display design, volume 1

    Get PDF
    Experiment computer application software (ECAS) display design and command usage guidelines were developed, which if followed by spacelab experiments, would standardize methods and techniques for data presentation and commanding via ECAS. These guidelines would provide some commonality among experiments which would enhance crew training and flight operations. The guidelines are applicable to all onboard experiment displays, whether allocated by ECAS or a dedicated experiment processor. A brief description of the spacelab data display system characteristics and of the services provided by the experiment computer operating system is included. Guidelines concerning data presentation and layout of alphanumeric and graphic information are presented along with guidelines concerning keyboard commanding and command feedback

    EV space suit gloves (passive)

    Get PDF
    A pair of pressure and thermal insulating overgloves to be used with an Extravehicular (EV) suit assembly was designed, developed, fabricated, and tested. The design features extensive use of Nomex felt materials in lieu of the multiple layer insulation formerly used with the Apollo thermal glove. The glove theoretically satisfies all of the thermal requirements. The presence of the thermal glove does not degrade pressure glove tactility by more than the acceptable 10% value. On the other hand, the thermal glove generally degrades pressure glove mobility by more than the acceptable 10% value, primarily in the area of the fingers. Life cycling tests were completed with minimal problems. The thermal glove/pressure glove ensemble was also tested for comfort; the test subjects found no problems with the thermal glove although they did report difficulties with pressure points on the pressure glove which were independent of the thermal glove

    Numerical Analysis for the Consumer

    Get PDF

    Arthroscopic subscapularis bankart technique as a salvage procedure for failed anterior shoulder stabilization

    Get PDF
    BACKGROUND: Shoulder instability is a relatively common problem. Even with contemporary surgical techniques, instability can recur following both open and arthroscopic fixation. Surgical management of capsular insufficiency in anterior shoulder stabilization represents a significant challenge, particularly in young, active patients. There are a limited number of surgical treatment options. The Laterjet technique can present with a number of intraoperative challenges and postoperative complication.; DESCRIPTION OF TECHNIQUE: We report an arthroscopic subscapularis tenodesis technique as a salvage procedure for challenging glenohumeral instability cases. Sutures are passed through the subscapularis tendon and capsule before they are tied as one in the subdeltoid psace. The rotator interval is closed with superior and medial advancement of anterior and inferior tissue. This technical note carefully describes this procedure with useful technical tips, illustrations, and diagrams.; PATIENTS AND METHODS: Two clinical cases are described involving patients with recurrent instability following failed surgery who were successfully managed with this procedure.; RESULTS: Both cases described resulted in improved shoulder stability, range of motion, and function following management with this surgical technique. This arthroscopic subscapularis tenodesis procedure is proposed as a useful alternative repair technique for cases of recurrent instability after failed surgery with isolated capsular insufficiency.; CONCLUSION: It is believed that this arthroscopic subscapularis tenodesis technique can potentially provide similar outcomes to open bone block stabilization procedures, while reducing the risks associated with those procedures

    Pulsars with the Australian Square Kilometre Array Pathfinder

    Full text link
    The Australian Square Kilometre Array Pathfinder (ASKAP) is a 36-element array with a 30-square-degree field of view being built at the proposed SKA site in Western Australia. We are conducting a Design Study for pulsar observations with ASKAP, planning both timing and search observations. We provide an overview of the ASKAP telescope and an update on pulsar-related progress.Comment: To appear in proceedings of "Radio Pulsars: An astrophysical key to unlock the secrets of the Universe

    Novel Properties of The Apparent Metal-Insulator Transition in Two-Dimensional Systems

    Full text link
    The low-temperature conductivity of low-density, high-mobility, two-dimensional hole systems in GaAs was studied. We explicitly show that the metal-insulator transition, observed in these systems, is characterized by a well-defined critical density, p_0c. We also observe that the low-temperature conductivity of these systems depends linearly on the hole density, over a wide density range. The high-density linear conductivity extrapolates to zero at a density close to the critical density.Comment: 4 Figure
    • …
    corecore