945 research outputs found

    Could Fractional Exhaled Nitric Oxide Test be Useful in Predicting Inhaled Corticosteroid Responsiveness in Chronic Cough? A Systematic Review

    Get PDF
    © 2016 Background Fractional exhaled nitric oxide (FENO) is a safe and convenient test for assessing T H 2 airway inflammation, which is potentially useful in the management of patients with chronic cough. Objective To summarize the current evidence on the diagnostic usefulness of FENO for predicting inhaled corticosteroid (ICS) responsiveness in patients with chronic cough. Methods A systematic literature review was conducted to identify articles published in peer-reviewed journals up to February 2015, without language restriction. We included studies that reported the usefulness of FENO (index test) for predicting ICS responsiveness (reference standard) in patients with chronic cough (target condition). The data were extracted to construct a 2 × 2 accuracy table. Study quality was assessed with Quality Assessment of Diagnostic Accuracy Studies 2. Results We identified 5 original studies (2 prospective and 3 retrospective studies). We identified considerable heterogeneities in study design and outcome definitions, and thus were unable to perform a meta-analysis. The proportion of ICS responders ranged from 44% to 59%. Sensitivity and specificity ranged from 53% to 90%, and from 63% to 97%, respectively. The reported area under the curve ranged from abou t 0.60 to 0.87; however, studies with a prospective design and a lower prevalence of asthma had lower area under the curve values. None measured placebo effects or objective cough frequency. Conclusions We did not find strong evidence to support the use of FENO tests for predicting ICS responsiveness in chronic cough. Further studies need to have a randomized, placebo-controlled design, and should use validated measurement tools for cough. Standardization would facilitate the development of clinical evidence

    Baseline Sensitivity of Echinochloa crus-gall and E. oryzicola to Florpyrauxifen-Benzyl, a New Synthetic Auxin Herbicide, in Korea

    Get PDF
    Echinochloa species is one of the most problematic weed species due to its high competitiveness and increasing herbicide resistance. Florpyrauxifen-benzyl, a new auxin herbicide, was recently introduced for Echinochloa management; however, the potential risk for the development of herbicide resistance in Echinochloa species has not been well-investigated. Thus, this study was conducted to evaluate the baseline sensitivity of Echinochloa species to florpyrauxifen-benzyl to estimate the risk of future resistance development. A total of 70 and 71 accessions of Echinochloa crus-galli and Echinochloa oryzicola were collected from paddy fields in Korea, respectively. These two Echinochloa species were grown in plastic pots up to the 5-leaf stage, and treated with florpyrauxifen-benzyl at a range of doses from 2.2 g to 70.0 g a.i. ha–1. Nonlinear regression analyses revealed that GR50 values for E. oryzicola ranged from 4.54 g to 29.66 g a.i. ha–1, giving a baseline sensitivity index (BSI) of 6.53, while those for E. crus-galli ranged from 6.15 g to 16.06 g a.i. ha–1, giving a BSI of 2.61. Our findings suggest that E. oryzicola has a greater potential risk than E. crus-galli for the development of metabolism-based resistance to florpyrauxifen-benzyl

    Differentiation of Recently Infarcted Myocardium from Chronic Myocardial Scar: The Value of Contrast-Enhanced SSFP-Based Cine MR Imaging

    Get PDF
    The purpose of this study is to demonstrate whether the signal intensity (SI) of myocardial infarction (MI) on contrast enhanced (CE)-cine MRI is useful for differentiating recently infarcted myocardium from chronic scar. This study included 24 patients with acute MI (36-84 years, mean age: 57) and 19 patients with chronic MI (44-80 years, mean age: 64). The diagnosis of acute MI was based on the presence of typical symptoms, i.e. elevation of the cardiac enzymes and the absence of any remote infarction history. The diagnosis of chronic MI was based on a history of MI or coronary artery disease of more than one month duration and on the absence of any recent MI within the previous six months. Retrospectively, the ECG-gated breath-hold cine imaging was performed in the short axis plane using a segmented, balanced, turbo-field, echo-pulse sequence two minutes after the administration of Gd-DTPA at a dose of 0.2 mmol/kg body weight. Delayed contrast-enhanced MRI (DCE MRI) in the same plane was performed 10 to 15 minutes after contrast administration, and this was served as the gold standard of reference. The SI of the infarcted myocardium on the CE-cine MRI was compared with that of the normal myocardium on the same image. The area of abnormal SI on the CE-cine MRI was compared with the area of hyperenhancement on the DCE MRI. The area of high SI on the CE-cine MRI was detected in 23 of 24 patients with acute MI (10 with homogenous high SI, 13 high SI with subendocardial low SI, and one with iso SI). The area of high SI on the CE-cine MRI was larger than that seen on the DCE MRI (p < 0.05). In contrast, the areas of chronic MI were seen as iso-SI with thin subendocardial low SI on the CE-cine MR in all the chronic MI patients. The presence of high SI on both the CE-cine MRI and the DCE MRI is more sensitive (95.8%) for determining the age of a MI than the presence of myocardial thinning (66.7%). This study showed the different SI patterns between recently infarcted myocardium and chronic scar on the CE-cine MRI. CE-cine MRI is thought to be quite useful for determining the age of myocardial infarction, in addition to its utility for assessing myocardial contractility

    Universal light-guiding geometry for on-chip resonators having extremely high Q-factor

    Get PDF
    By providing an effective way to leverage nonlinear phenomena in integrated devices, high-Q optical resonators have led to recent advances in on-chip photonics. However, developing fabrication processes to shape any new material into a resonator with extremely smooth surfaces on a chip has been an exceptionally challenging task. Here, we describe a universal method to implement ultra-high-Q resonators with any new material having desirable properties that can be deposited by physical vapor deposition. Using this method light-guiding cores with surface roughness on the molecular-scale are created automatically on pre-patterned substrates. Its efficacy has been verified using As2S3, a chalcogenide glass that has high-nonlinearity. The Q-factor of the As2S3 resonator so-developed approached the propagation loss record achieved in chalcogenide fibers which were limited by material losses. Owing to the boosted Q-factor, lasing by stimulated Brillouin scattering has been demonstrated with 100 times lower threshold power than the previous record.This work was supported by Samsung Research Funding & Incubation Center of Samsung Electronics under Project Number SRFC-IT1801-03

    Universal light-guiding geometry for on-chip resonators having extremely high Q-factor

    Get PDF
    By providing an effective way to leverage nonlinear phenomena in integrated devices, high-Q optical resonators have led to recent advances in on-chip photonics. However, developing fabrication processes to shape any new material into a resonator with extremely smooth surfaces on a chip has been an exceptionally challenging task. Here, we describe a universal method to implement ultra-high-Q resonators with any new material having desirable properties that can be deposited by physical vapor deposition. Using this method light-guiding cores with surface roughness on the molecular-scale are created automatically on pre-patterned substrates. Its efficacy has been verified using As2S3, a chalcogenide glass that has high-nonlinearity. The Q-factor of the As2S3 resonator so-developed approached the propagation loss record achieved in chalcogenide fibers which were limited by material losses. Owing to the boosted Q-factor, lasing by stimulated Brillouin scattering has been demonstrated with 100 times lower threshold power than the previous record. © 2020, The Author(s).1

    Analysis of Endoscopic Electronic Image of Intramucosal Gastric Carcinoma Using a Software Program for Calculating Hemoglobin Index

    Get PDF
    Hemoglobin is the predominent pigment in the gastrointestinal mucosa, and the development of electronic endoscopy has made it possible to quantitatively measure the mucosal hemoglobin volume, by using a hemoglobin index (IHb). The aims of this study were to make a software program to calculate the IHb and then to investigate whether the mucosal IHb determined from the electronic endoscopic data is a useful marker for evaluating the color of intramucosal gastric carcinoma with regard to its value for discriminating between the histologic types. We made a software program for calculating the IHb in the endoscopic images. By using this program, the mean values of the IHb for the carcinoma (IHb-C) and those of the IHb for the surrounding non-cancerous mucosa (IHb-N) were calculated in 75 intestinal-type and 34 diffuse-type intramucosal gastric carcinomas. We then analyzed the ratio of the IHb-C to the IHb-N (C/N ratio). The C/N ratio in the intestinal-type carcinoma group was higher than that in the diffuse-type carcinoma group (p<0.001). In the diffuse-type carcinoma group, the C/N ratio in the body was lower than that in the antrum (p=0.022). The accuracy rate, sensitivity, specificity, and the positive and negative predictive values for the differential diagnosis of the diffuse-type carcinoma from the intestinal-type carcinoma were 94.5%, 94.1%, 94.7%, 88.9% and 97.3%, respectively. IHb is useful for making quantitative measurement of the endoscopic color in the intramucosal gastric carcinoma, and the C/N ratio by using the IHb would be helpful for distinguishing the diffuse-type carcinoma from the intestinal-type carcinoma
    corecore