52 research outputs found

    TYPE D PERSONALITY IN PATIENTS WITH CORONARY ARTERY DISEASE

    Get PDF
    Background: During the past decade studies have shown that Type D personality is associated with increased risk of cardiac events, mortality and poor quality of life. Some authors suggested that depression and Type D personality have substantial phenomenological overlap. Subjects and methods: The sample consisted of non-consecutive case series of seventy nine patients with clinically stable and angiographically confirmed coronary artery disease (CAD), who had been admitted to the Clinic of Cardiology, University Clinical Centre, from May 2006 to September 2008. The patients were assessed by the Type-D scale (DS14), The Beck Depression Inventory (BDI), and provided demographic information. Risk factors for CAD were obtained from cardiologists. Results: The findings of our study have shown that 34.2% patients with CAD could be classified as Type D personality. The univariate analysis has shown that the prevalence of Type D personality was significantly higher in individuals with unstable angina pectoris and myocardial infarction (MI) diagnoses (p=0.02). Furthermore, some components of metabolic syndrome were more prevalent in patients with Type D personality: hypercholesterolemia (p=0.00), hypertriglyceridemia (p=0.00) and hypertension (p=0.01). Additionally, the distribution of depression in patients with a Type D personality and a non-Type D personality were statistically significantly different (p=0.00). Conclusion: To our knowledge, this study is the first one to describe the prevalence and clinical characteristics of the Type D personality in patients with CAD in this region of Europe. We have found that the prevalence of Type D personality in patients with CAD is in concordance with the other studies. We also have found that Type D personality and depression are two distinctly different categories of psychological distress

    Left atrial volume changes during exercise stress echocardiography in heart failure and hypertrophic cardiomyopathy

    Get PDF
    We assessed feasibility and functional correlates of LAVI (left atrial volume index) changes during exercise stress echocardiography (ESE).ESE on bike or treadmill was performed in 363 patients with heart failure with preserved ejection fraction (HFpEF, n = 173), reduced ejection fraction (HFrEF, n = 59) or hypertrophic cardiomyopathy (HCM, n=131). LAVI stress-rest increase ≥ 6.8 ml/m2 was defined as dilation.LAVI measurements were feasible in 100%. LAVI did not change in HFrEF being at rest 32 (25-45) vs. at stress 36 (24 - 54) ml/m2, P = NS and in HCM at rest 35 (26 - 48) vs. at stress 38 (28 - 48) ml/m2, P = NS whereas it decreased in HFpEF from 30 (24 -40) to 29 (21 - 37) ml/m2 at stress, P = 0.007. LA dilation occurred in 107 (30%) patients (27% with treadmill vs. 33% with bike ESE, P = NS): 26 with HFpEF (15%), 26 with HFrEF (44%) and 55 with HCM (42%) with P 14 at rest with OR 4.4, LVEF < 50% with OR 2.9, and LAVI at rest < 35 ml/m2 with OR 2.7.LAVI assessment during ESE was highly feasible and dilation equally frequent with treadmill or bike. LA dilation was threefold more frequent in HCM and HFrEF and could be predicted by increased resting E/e' and impaired EF as well as smaller baseline LAVI

    Prognostic value of reduced heart rate reserve during exercise in hypertrophic cardiomyopathy

    Get PDF
    Background: Sympathetic dysfunction can be evaluated by heart rate reserve (HRR) with exercise test. Objectives: To determine the value of HRR in predicting outcome of patients with hypertrophic cardiomyopathy (HCM). Methods: We enrolled 917 HCM patients (age = 49 +/- 15 years, 516 men) assessed with exercise stress echocardiography (ESE) in 11 centres. ESE modality was semi-supine bicycle in 51 patients (6%), upright bicycle in 476 (52%), and treadmill in 390 (42%). During ESE, we assessed left ventricular outflow tract obstruction (LVOTO), stress-induced new regional wall motion abnormalities (RWMA), and HRR (peak/rest heart rate, HR). By selection, all patients completed the follow-up. Mortality was the predetermined outcome measure Results: During ESE, RWMA occurred in 22 patients (2.4%) and LVOTO (>= 50 mmHg) in 281 (30.4%). HRR was 1.90 +/- 0.40 (lowest quartile 2.13). Higher resting heart rate (odds ratio 1.027, 95% CI: 1.018-1.036, p < 0.001), older age (odds ratio 1.021, 95% CI: 1.009-1.033, p < 0.001), lower exercise tolerance (mets, odds ratio 0.761, 95% CI: 0.708-0.817, p < 0.001) and resting LVOTO (odds ratio 1.504, 95% CI: 1.043-2.170, p = 0.029) predicted a reduced HRR. During a median follow-up of 89 months (interquartile range: 36-145 months), 90 all-cause deaths occurred. At multivariable analysis, lowest quartile HRR (Hazard ratio 2.354, 95% CI 1.116-4.968 p = 0.025) and RWMA (Hazard ratio 3.279, 95% CI 1.441-7.461 p = 0.004) independently predicted death, in addition to age (Hazard ratio 1.064, 95% CI 1.043-1.085 p < 0.001) and maximal wall thickness (Hazard ratio 1.081, 95% CI 1.037-1.128, p < 0.001). Conclusions: A blunted HRR during ESE predicts survival independently of RWMA in HCM patients.info:eu-repo/semantics/publishedVersio

    Comparison of exercise, dobutamine-atropine and dipyridamole-atropine stress echocardiography in detecting coronary artery disease

    Get PDF
    BACKGROUND: Dipyridamole and dobutamine stress echocardiography testing are most widely utilized, but their sensitivity remained suboptimal in comparison to routine exercise stress echocardiography. The aim of our study is to compare, head-to-head, exercise, dobutamine and dipyridamole stress echocardiography tests, performed with state-of-the-art protocols in a large scale prospective group of patients. METHODS: Dipyridamole-atropine (Dipatro: 0.84 mg/kg over 10 min i.v. dipyridamole with addition of up to 1 mg of atropine), dobutamine-atropine (Dobatro: up to 40 mcg/kg/min i.v. dobutamine with addition of up to 1 mg of atropine) and exercise (Ex, Bruce) were performed in 166 pts. Of them, 117 pts without resting wall motion abnormalities were enrolled in study (91 male; mean age 54 ± 10 years; previous non-transmural myocardial infarction in 32 pts, angina pectoris in 69 pts and atypical chest pain in 16 pts). Tests were performed in random sequence, in 3 different days, within 5 day period under identical therapy. All patients underwent coronary angiography. RESULTS: Significant coronary artery disease (CAD; ≥50% diameter stenosis) was present in 69 pts (57 pts 1-vessel CAD, 12 multivessel CAD) and absent in 48 pts. Sensitivity (Sn) was 96%, 93% and 90%, whereas specificity (Sp) was 92%, 92% and 87% for Dobatro, Dipatro and Ex, respectively (p = ns). Concomitant beta blocker therapy did not influence peak rate-pressure product and Sn of Dobatro and Dipatro (p = ns). CONCLUSION: When state-of-the-art protocols are used, dipyridamole and dobutamine stress echocardiography have comparable and high diagnostic accuracy, similar to maximal post-exercise treadmill stress echocardiography

    Low-dose adenosine stress echocardiography: Detection of myocardial viability

    Get PDF
    OBJECTIVE: The aim of this study was to evaluate the diagnostic potential of low-dose adenosine stress echocardiography in detection of myocardial viability. BACKGROUND: Vasodilation through low dose dipyridamole infusion may recruit contractile reserve by increasing coronary flow or by increasing levels of endogenous adenosine. METHODS: Forty-three patients with resting dyssynergy, due to previous myocardial infarction, underwent low-dose adenosine (80, 100, 110 mcg/kg/min in 3 minutes intervals) echocardiography test. Gold standard for myocardial viability was improvement in systolic thickening of dyssinergic segments of ≥ 1 grade at follow-up. Coronary angiography was done in 41 pts. Twenty-seven patients were revascularized and 16 were medically treated. Echocardiographic follow up data (12 ± 2 months) were available in 24 revascularized patients. RESULTS: Wall motion score index improved from rest 1.55 ± 0.30 to 1.33 ± 0.26 at low-dose adenosine (p < 0.001). Of the 257 segments with baseline dyssynergy, adenosine echocardiography identified 122 segments as positive for viability, and 135 as necrotic since no improvement of systolic thickening was observed. Follow-up wall motion score index was 1.31 ± 0.30 (p < 0.001 vs. rest). The sensitivity of adenosine echo test for identification of viable segments was 87%, while specificity was 95%, and diagnostic accuracy 90%. Positive and negative predictive values were 97% and 80%, respectively. CONCLUSION: Low-dose adenosine stress echocardiography test has high diagnostic potential for detection of myocardial viability in the group of patients with left ventricle dysfunction due to previous myocardial infarction. Low dose adenosine stress echocardiography may be adequate alternative to low-dose dobutamine test for evaluation of myocardial viability

    Stress echo 2020 : the international stress echo study in ischemic and non-ischemic heart disease

    Get PDF
    Background: Stress echocardiography (SE) has an established role in evidence-based guidelines, but recently its breadth and variety of applications have extended well beyond coronary artery disease (CAD). We lack a prospective research study of SE applications, in and beyond CAD, also considering a variety of signs in addition to regional wall motion abnormalities. Methods: In a prospective, multicenter, international, observational study design, > 100 certified high-volume SE labs (initially from Italy, Brazil, Hungary, and Serbia) will be networked with an organized system of clinical, laboratory and imaging data collection at the time of physical or pharmacological SE, with structured follow-up information. The study is endorsed by the Italian Society of Cardiovascular Echography and organized in 10 subprojects focusing on: contractile reserve for prediction of cardiac resynchronization or medical therapy response; stress B-lines in heart failure; hypertrophic cardiomyopathy; heart failure with preserved ejection fraction; mitral regurgitation after either transcatheter or surgical aortic valve replacement; outdoor SE in extreme physiology; right ventricular contractile reserve in repaired Tetralogy of Fallot; suspected or initial pulmonary arterial hypertension; coronary flow velocity, left ventricular elastance reserve and B-lines in known or suspected CAD; identification of subclinical familial disease in genotype-positive, phenotype- negative healthy relatives of inherited disease (such as hypertrophic cardiomyopathy). Results: We expect to recruit about 10,000 patients over a 5-year period (2016-2020), with sample sizes ranging from 5,000 for coronary flow velocity/ left ventricular elastance/ B-lines in CAD to around 250 for hypertrophic cardiomyopathy or repaired Tetralogy of Fallot. This data-base will allow to investigate technical questions such as feasibility and reproducibility of various SE parameters and to assess their prognostic value in different clinical scenarios. Conclusions: The study will create the cultural, informatic and scientific infrastructure connecting high-volume, accredited SE labs, sharing common criteria of indication, execution, reporting and image storage of SE to obtain original safety, feasibility, and outcome data in evidence-poor diagnostic fields, also outside the established core application of SE in CAD based on regional wall motion abnormalities. The study will standardize procedures, validate emerging signs, and integrate the new information with established knowledge, helping to build a next-generation SE lab without inner walls

    Quality control of B-lines analysis in stress Echo 2020

    Get PDF
    Background The effectiveness trial “Stress echo (SE) 2020” evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. Purpose To provide web-based upstream quality control and harmonization of B-lines reading criteria. Methods 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module ( http://se2020.altervista.org ). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. Results All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p < .01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p < .01). Conclusions Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly.info:eu-repo/semantics/publishedVersio
    corecore