8,621 research outputs found
A Model for Using Physiological Conditions for Proactive Tourist Recommendations
Mobile proactive tourist recommender systems can support tourists by
recommending the best choice depending on different contexts related to herself
and the environment. In this paper, we propose to utilize wearable sensors to
gather health information about a tourist and use them for recommending tourist
activities. We discuss a range of wearable devices, sensors to infer
physiological conditions of the users, and exemplify the feasibility using a
popular self-quantification mobile app. Our main contribution then comprises a
data model to derive relations between the parameters measured by the wearable
sensors, such as heart rate, body temperature, blood pressure, and use them to
infer the physiological condition of a user. This model can then be used to
derive classes of tourist activities that determine which items should be
recommended
Development and parametric evaluation of the prototype 2 and 3 flash evaporators
Development of the Prototype 2 and 3 flash evaporator heat sinks which vaporize an expendable fluid to cool a heat transport fluid loop is reported. The units utilize Freon 21 as the heat transport fluid and water as the expendable fluid to meet the projected performance requirements of the space shuttle for both on-orbit and ascent/reentry operations. The evaporant is pulse-sprayed by on-off control onto heat transfer surfaces containing the transport fluid and exhausted to the vacuum environment through fixed area exhaust ducts
Demonstration of rapid and sensitive module leak certification for Space Station Freedom
A leak detection and quantification demonstration using perflurocarbon tracer (PFT) technology was successfully performed at the NASA Marshall Space Flight Center on January 25, 1991. The real-time Dual Trap Analyzer (DTA) at one-half hour after the start of the first run gave an estimated leak rate of 0.7 mL/min. This has since been refined to be 1.15 (+ or -) 0.09 mL/min. The leak rates in the next three runs were determined to be 9.8 (+ or -) 0.7, -0.4 (+ or -) 0.3, and 76 (+ or -) 6 mL/min, respectively. The theory on leak quantification in the steady-state and time-dependent modes for a single zone test facility was developed and applied to the above determinations. The laboratory PFT analysis system gave a limit-of-detection (LOD) of 0.05 fL for ocPDCH. This is the tracer of choice and is about 100-fold better than that for the DTA. Applied to leak certification, the LOD is about 0.00002 mL/s (0.000075 L/h), a 5 order-of-magnitude improvement over the original leak certification specification. Furthermore, this limit can be attained in a measurement period of 3 to 4 hours instead of days, weeks, or months. A new Leak Certification Facility is also proposed to provide for zonal (three zones) determination of leak rates. The appropriate multizone equations, their solutions, and error analysis have already been derived. A new concept of seal-integrity certification has been demonstrated for a variety of controlled leaks in the range of module leak testing. High structural integrity leaks were shown to have a linear dependence of flow on (Delta)p. The rapid determination of leak rates at different pressures is proposed and is to be determined while subjecting the module to other external force-generating parameters such as vibration, torque, solar intensity, etc
Static axisymmetric spacetimes with non-generic world-line SUSY
The conditions for the existence of Killing-Yano tensors, which are closely
related to the appearance of non-generic world-line SUSY, are presented for
static axisymmetric spacetimes. Imposing the vacuum Einstein equation, the set
of solutions admitting Killing-Yano tensors is considered. In particular, it is
shown that static, axisymmetric and asymptotically flat vacuum solutions
admitting Killing-Yano tensors are only the Schwarzschild solution.Comment: 10 pages (RevTeX), TIT/HEP-253/COSMO-4
Classical gravitational spin-spin interaction
I obtain an exact, axially symmetric, stationary solution of Einstein's
equations for two massless spinning particles. The term representing the
spin-spin interaction agrees with recently published approximate work. The
spin-spin force appears to be proportional to the inverse fourth power of the
coordinate distance between the particles.Comment: six pages, no figures, journal ref:accepted for Classical and Quantum
Gravit
On the dynamic stability of eccentrically reinforced circular cylindrical shells Technical report, Sep. 1, 1965 - Jan. 31, 1967
Dynamic stability of eccentrically reinforced circular cylindrical shell
On the Formulation of Equations of Motion of an Eccentrically Stiffened Shallow Circular Cylindrical Shell Semiannual Progress Report, Sep. 1, 1965 - Mar. 1, 1966
Motion equations formulation for eccentrically stiffened shallow circular cylindrical shel
National Transonic Facility: A review of the operational plan
The proposed National Transonic Facility (NTF) operational plan is reviewed. The NTF will provide an aerodynamic test capability significantly exceeding that of other transonic regime wind tunnels now available. A limited number of academic research program that might use the NTF are suggested. It is concluded that the NTF operational plan is useful for management, technical, instrumentation, and model building techniques available in the specialized field of aerodynamic analysis and simulation. It is also suggested that NASA hold an annual conference to discuss wind tunnel research results and to report on developments that will further improve the utilization and cost effectiveness of the NTF and other wind tunnels
- …