    Performance of seven ECG interpretation programs in identifying arrhythmia and acute cardiovascular syndrome

    Get PDF
    Abstract Background No direct comparison of current electrocardiogram (ECG) interpretation programs exists. Objective Assess the accuracy of ECG interpretation programs in detecting abnormal rhythms and flagging for priority review records with alterations secondary to acute coronary syndrome (ACS). Methods More than 2,000 digital ECGs from hospitals and databases in Europe, USA, and Australia, were obtained from consecutive adult and pediatric patients and converted to 10 s analog samples that were replayed on seven electrocardiographs and classified by the manufacturers' interpretation programs. We assessed ability to distinguish sinus rhythm from non-sinus rhythm, identify atrial fibrillation/flutter and other abnormal rhythms, and accuracy in flagging results for priority review. If all seven programs' interpretation statements did not agree, cases were reviewed by experienced cardiologists. Results All programs could distinguish well between sinus and non-sinus rhythms and could identify atrial fibrillation/flutter or other abnormal rhythms. However, false-positive rates varied from 2.1% to 5.5% for non-sinus rhythm, from 0.7% to 4.4% for atrial fibrillation/flutter, and from 1.5% to 3.0% for other abnormal rhythms. False-negative rates varied from 12.0% to 7.5%, 9.9% to 2.7%, and 55.9% to 30.5%, respectively. Flagging of ACS varied by a factor of 2.5 between programs. Physicians flagged more ECGs for prompt review, but also showed variance of around a factor of 2. False-negative values differed between programs by a factor of 2 but was high for all (>50%). Agreement between programs and majority reviewer decisions was 46–62%. Conclusions Automatic interpretations of rhythms and ACS differ between programs. Healthcare institutions should not rely on ECG software "critical result" flags alone to decide the ACS workflow

    Glomerular filtration rate in patients with atrial fibrillation and 1-year outcomes

    Get PDF
    We assessed 1-year outcomes in patients with atrial fibrillation enrolled in the EurObservational Research Programme AF General Pilot Registry (EORP-AF), in relation to kidney function, as assessed by glomerular filtration rate (eGFR). In a cohort of 2398 patients (median age 69 years; 61% male), eGFR (ml/min/1.73 m(2)) calculated using the CKD-EPI formula was ≥80 in 35.1%, 50-79 in 47.2%, 30-49 in 13.9% and <30 in 3.7% of patients. In a logistic regression analysis, eGFR category was an independent predictor of stroke/TIA or death, with elevated odds ratios associated with severe to mild renal impairment, ie. eGFR < 30 ml/min/1.73 m(2) [OR 3.641, 95% CI 1.572-8.433, p < 0.0001], 30-49 ml/min/1.73 m(2) [OR 3.303, 95% CI 1.740-6.270, p = 0.0026] or 50-79 ml/min/1.73 m2 [OR 2.094, 95% CI 1.194-3.672, p = 0.0003]. The discriminant capability for the risk of death was tested among various eGFR calculation algorithms: the best was the Cockcroft-Gault equation adjusted for BSA, followed by Cockcroft-Gault equation, and CKD-EPI equation, while the worst was the MDRD equation. In conclusion in this prospective observational registry, renal function was a major determinant of adverse outcomes at 1 year, and even mild or moderate renal impairments were associated with an increased risk of stroke/TIA/death

    Use of Diltiazem in Chronic Rate Control for Atrial Fibrillation: A Prospective Case-Control Study

    Get PDF
    Atrial fibrillation (AF) is a multifaceted disease requiring personalised treatment. The aim of our study was to explore the prognostic impact of a patient-specific therapy (PT) for rate control, including the use of non-dihydropyridine calcium channel blockers (NDDC) in patients with heart failure (HF) or in combination with beta-blockers (BB), compared to standard rate control therapy (ST), as defined by previous ESC guidelines. This is a single-centre prospective observational registry on AF patients who were followed by our University Hospital. We included 1112 patients on an exclusive rate control treatment. The PT group consisted of 125 (11.2%) patients, 93/125 (74.4%) of whom were prescribed BB + NDCC (±digoxin), while 85/125 (68.0%) were HF patients who were prescribed NDCC, which was diltiazem in all cases. The patients treated with a PT showed no difference in one-year overall survival compared to those with an ST. Notably, the patients with HF in ST had a worse prognosis (p < 0.001). To better define this finding, we performed three sensitivity analyses by matching each patient in the PT subgroups with three subjects from the ST cohort, showing an improved one-year survival of the HF patients treated with PT (p = 0.039). Our results suggest a potential outcome benefit of NDCC for rate control in AF patients, either alone or in combination with BB and in selected patients with HF

    Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads

    Get PDF
    We evaluated the performance of 3 different left ventricular leads (LV) for resynchronization therapy: bipolar (BL), quadripolar (QL) and active fixation leads (AFL). We enrolled 290 consecutive CRTD candidates implanted with BL (n = 136) or QL (n = 97) or AFL (n = 57). Over a minimum 10 months follow-up, we assessed: (a) composite technical endpoint (TE) (phrenic nerve stimulation at 8 [email protected] ms, safety margin between myocardial and phrenic threshold <2V, LV dislodgement and failure to achieve the target pacing site), (b) composite clinical endpoint (CE) (death, hospitalization for heart failure, heart transplantation, lead extraction for infection), (c) reverse remodeling (RR) (reduction of end systolic volume >15%). Baseline characteristics of the 3 groups were similar. At follow-up the incidence of TE was 36.3%, 14.3% and 19.9% in BL, AFL and QL, respectively (p < 0.01). Moreover, the incidence of RR was 56%, 64% and 68% in BL, AFL and QL respectively (p = 0.02). There were no significant differences in CE (p = 0.380). On a multivariable analysis, \u201cnon-BL leads\u201d was the single predictor of an improved clinical outcome. QL and AFL are superior to conventional BL by enhancing pacing of the target site: AFL through prevention of lead dislodgement while QL through improved management of phrenic nerve stimulation

    Glomerular filtration rate in patients with atrial fibrillation and 1-year outcomes

    Get PDF
    We assessed 1-year outcomes in patients with atrial fibrillation enrolled in the EurObservational Research Programme AF General Pilot Registry (EORP-AF), in relation to kidney function, as assessed by glomerular filtration rate (eGFR). In a cohort of 2398 patients (median age 69 years; 61% male), eGFR (ml/min/1.73\u2009m(2)) calculated using the CKD-EPI formula was 6580 in 35.1%, 50-79 in 47.2%, 30-49 in 13.9% and <30 in 3.7% of patients. In a logistic regression analysis, eGFR category was an independent predictor of stroke/TIA or death, with elevated odds ratios associated with severe to mild renal impairment, ie. eGFR\u2009<\u200930\u2009ml/min/1.73\u2009m(2) [OR 3.641, 95% CI 1.572-8.433, p\u2009<\u20090.0001], 30-49\u2009ml/min/1.73\u2009m(2) [OR 3.303, 95% CI 1.740-6.270, p\u2009=\u20090.0026] or 50-79\u2009ml/min/1.73\u2009m2 [OR 2.094, 95% CI 1.194-3.672, p\u2009=\u20090.0003]. The discriminant capability for the risk of death was tested among various eGFR calculation algorithms: the best was the Cockcroft-Gault equation adjusted for BSA, followed by Cockcroft-Gault equation, and CKD-EPI equation, while the worst was the MDRD equation. In conclusion in this prospective observational registry, renal function was a major determinant of adverse outcomes at 1 year, and even mild or moderate renal impairments were associated with an increased risk of stroke/TIA/death

    Drug management of atrial fibrillation in light of guidelines and current evidence: an Italian Survey on behalf of Italian Association of Arrhythmology and Cardiac Pacing

    Get PDF
    AimAtrial fibrillation is a multifaceted disease requiring personalized treatment, in accordance with current ESC guidelines. Despite a wide range of literature, we still have various aspects dividing the opinion of the experts in rate control, rhythm control and thromboembolic prophylaxis. The aim of this survey was to provide a country-wide picture of current practice regarding atrial fibrillation pharmacological management according to a patient's characteristics.MethodsData were collected using an in-person survey that was administered to members of the Italian Association of Arrhythmology and Cardiac Pacing.ResultsWe collected data from 106 physicians, working in 72 Italian hospitals from 15 of 21 regions. Our work evidenced a high inhomogeneity in atrial fibrillation management regarding rhythm control, rate control and thromboembolic prophylaxis in both acute and chronic patients. This element was more pronounced in settings in which literature shows a lack of evidence and, consequently, the indications provided by the guidelines are weak or absent.ConclusionThis National survey evidenced a high inhomogeneity in current approaches adopted for atrial fibrillation management by a sample of Italian cardiologist experts in arrhythmia management. Further studies are needed to explore if these divergences are associated with different long-term outcomes
    • …