2,587 research outputs found
An impedimetric immunosensor for the selective detection of CD34+ T-cells in human serum
Chimeric antigen receptor T (CAR-T) cell therapy has led to a paradigm change in cancer treatment. To allow widespread use of this therapy, it is important to reduce the costs associated with cells manufacturing whilst ensuring a high-quality production. Online biosensors can help monitor in real time the effectiveness of engineering CAR-T cells, with the possibility to be integrated on the workflow without the need to extract samples for off line analysis that require specialised personnel and expensive analytical equipment. In this context, we present an innovative label-free impedimetric immunosensor for the detection of CD34 + T-cells in human serum. The sensor is based on screen-printed gold electrodes functionalised with anti-CD34 antibody, via a mixed self-assembled monolayer of 11-mercaptoundecanoic acid and 6-mercapto-1-hexanol, which recognizes the CD34 antigen expressed onto the T-cells surfaces. The immunosensor exhibits a high selectivity and a wide working range in human serum, both in Faradaic and non-Faradaic detection conditions, being respectively of 230 – 1.4 × 10 3 cell mL −1 and 50 – 1 × 10 5 cell mL −1. This result, along with performance validation both in batch and flow-through operations, demonstrates the applicability of the developed immunosensor for clinical use. </p
Analysis of the 'Endoworm' prototype's ability to grip the bowel in in vitro and ex vivo models
[EN] Access to the small bowel by means of an enteroscope is difficult, even using current devices such as single-balloon or double-balloon enteroscopes. Exploration time and patient discomfort are the main drawbacks. The prototype 'Endoworm' analysed in this paper is based on a pneumatic translation system that, gripping the bowel, enables the endoscope to move forward while the bowel slides back over its most proximal part. The grip capacity is related to the pressure inside the balloon, which depends on the insufflate volume of air. Different materials were used as in vitro and ex vivo models: rigid polymethyl methacrylate, flexible silicone, polyester urethane and ex vivo pig small bowel. On measuring the pressure-volume relationship, we found that it depended on the elastic properties of the lumen and that the frictional force depended on the air pressure inside the balloons and the lumen's elastic properties. In the presence of a lubricant, the grip on the simulated intestinal lumens was drastically reduced, as was the influence of the lumen's properties. This paper focuses on the Endoworm's ability to grip the bowel, which is crucial to achieving effective endoscope forward advance and bowel foldingThe author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: The study was funded by the Spanish Ministry of Economy and Competitiveness through Project (PI18/01365) and by the UPV/IIS LA Fe through the (Endoworm 3.0) Project. CIBER-BBN is an initiative funded by the VI National R&D&I Plan 2008-2011, Iniciativa Ingenio 2010, Consolider Program, CIBER Actions and financed by the Instituto de Salud Carlos III with the assistance of the European Regional Development FundTobella, J.; Pons-Beltrán, V.; Santonja, A.; Sánchez-Diaz, C.; Campillo Fernandez, AJ.; Vidaurre, A. (2020). Analysis of the 'Endoworm' prototype's ability to grip the bowel in in vitro and ex vivo models. Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine. 234(5):1-10. https://doi.org/10.1177/09544119209014141102345Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000). Wireless capsule endoscopy. Nature, 405(6785), 417-417. doi:10.1038/35013140Yamamoto, H., Sekine, Y., Sato, Y., Higashizawa, T., Miyata, T., Iino, S., … Sugano, K. (2001). Total enteroscopy with a nonsurgical steerable double-balloon method. Gastrointestinal Endoscopy, 53(2), 216-220. doi:10.1067/mge.2001.112181Arnott, I. D. R., & Lo, S. K. (2004). REVIEW: The Clinical Utility of Wireless Capsule Endoscopy. Digestive Diseases and Sciences, 49(6), 893-901. doi:10.1023/b:ddas.0000034545.58486.e6Hosoe, N., Takabayashi, K., Ogata, H., & Kanai, T. (2019). Capsule endoscopy for small‐intestinal disorders: Current status. Digestive Endoscopy, 31(5), 498-507. doi:10.1111/den.13346Fukumoto, A., Tanaka, S., Shishido, T., Takemura, Y., Oka, S., & Chayama, K. (2009). Comparison of detectability of small-bowel lesions between capsule endoscopy and double-balloon endoscopy for patients with suspected small-bowel disease. Gastrointestinal Endoscopy, 69(4), 857-865. doi:10.1016/j.gie.2008.06.007Akerman, P. A., Agrawal, D., Chen, W., Cantero, D., Avila, J., & Pangtay, J. (2009). Spiral enteroscopy: a novel method of enteroscopy by using the Endo-Ease Discovery SB overtube and a pediatric colonoscope. Gastrointestinal Endoscopy, 69(2), 327-332. doi:10.1016/j.gie.2008.07.042Moreels, T. G. (2017). Update in enteroscopy: New devices and new indications. Digestive Endoscopy, 30(2), 174-181. doi:10.1111/den.12920Pasha, S. F. (2012). Diagnostic yield of deep enteroscopy techniques for small-bowel bleeding and tumors. Techniques in Gastrointestinal Endoscopy, 14(2), 100-105. doi:10.1016/j.tgie.2012.02.001Lenz, P., & Domagk, D. (2012). Double- vs. single-balloon vs. spiral enteroscopy. Best Practice & Research Clinical Gastroenterology, 26(3), 303-313. doi:10.1016/j.bpg.2012.01.021Baniya, R., Upadhaya, S., Subedi, S. C., Khan, J., Sharma, P., Mohammed, T. S., … Jamil, L. H. (2017). Balloon enteroscopy versus spiral enteroscopy for small-bowel disorders: a systematic review and meta-analysis. Gastrointestinal Endoscopy, 86(6), 997-1005. doi:10.1016/j.gie.2017.06.015Menciassi, A., & Dario, P. (2003). Bio-inspired solutions for locomotion in the gastrointestinal tract: background and perspectives. Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences, 361(1811), 2287-2298. doi:10.1098/rsta.2003.1255Zarrouk, D., Sharf, I., & Shoham, M. (2011). Analysis of Wormlike Robotic Locomotion on Compliant Surfaces. IEEE Transactions on Biomedical Engineering, 58(2), 301-309. doi:10.1109/tbme.2010.2066274Poon, C. C. Y., Leung, B., Chan, C. K. W., Lau, J. Y. W., & Chiu, P. W. Y. (2015). Design of wormlike automated robotic endoscope: dynamic interaction between endoscopic balloon and surrounding tissues. Surgical Endoscopy, 30(2), 772-778. doi:10.1007/s00464-015-4224-8Kassim, I., Phee, L., Ng, W. S., Feng Gong, Dario, P., & Mosse, C. A. (2006). Locomotion techniques for robotic colonoscopy. IEEE Engineering in Medicine and Biology Magazine, 25(3), 49-56. doi:10.1109/memb.2006.1636351Kim, Y.-T., & Kim, D.-E. (2010). Novel Propelling Mechanisms Based on Frictional Interaction for Endoscope Robot. Tribology Transactions, 53(2), 203-211. doi:10.1080/10402000903125337Massalou, D., Masson, C., Foti, P., Afquir, S., Baqué, P., Berdah, S.-V., & Bège, T. (2016). Dynamic biomechanical characterization of colon tissue according to anatomical factors. Journal of Biomechanics, 49(16), 3861-3867. doi:10.1016/j.jbiomech.2016.10.023Egorov, V. I., Schastlivtsev, I. V., Prut, E. V., Baranov, A. O., & Turusov, R. A. (2002). Mechanical properties of the human gastrointestinal tract. Journal of Biomechanics, 35(10), 1417-1425. doi:10.1016/s0021-9290(02)00084-2Hoeg, H. D., Slatkin, A. B., Burdick, J. W., & Grundfest, W. S. (s. f.). Biomechanical modeling of the small intestine as required for the design and operation of a robotic endoscope. Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065). doi:10.1109/robot.2000.844825Terry, B. S., Passernig, A. C., Hill, M. L., Schoen, J. A., & Rentschler, M. E. (2012). Small intestine mucosal adhesivity to in vivo capsule robot materials. Journal of the Mechanical Behavior of Biomedical Materials, 15, 24-32. doi:10.1016/j.jmbbm.2012.06.018Kim, J.-S., Sung, I.-H., Kim, Y.-T., Kwon, E.-Y., Kim, D.-E., & Jang, Y. H. (2006). Experimental investigation of frictional and viscoelastic properties of intestine for microendoscope application. Tribology Letters, 22(2), 143-149. doi:10.1007/s11249-006-9073-0Lyle, A. B., Luftig, J. T., & Rentschler, M. E. (2013). A tribological investigation of the small bowel lumen surface. Tribology International, 62, 171-176. doi:10.1016/j.triboint.2012.11.018De Simone, A., & Luongo, A. (2013). Nonlinear viscoelastic analysis of a cylindrical balloon squeezed between two rigid moving plates. International Journal of Solids and Structures, 50(14-15), 2213-2223. doi:10.1016/j.ijsolstr.2013.03.028Sliker, L. J., Ciuti, G., Rentschler, M. E., & Menciassi, A. (2016). Frictional resistance model for tissue-capsule endoscope sliding contact in the gastrointestinal tract. Tribology International, 102, 472-484. doi:10.1016/j.triboint.2016.06.003Zhang, C., Liu, H., & Li, H. (2014). Experimental investigation of intestinal frictional resistance in the starting process of the capsule robot. Tribology International, 70, 11-17. doi:10.1016/j.triboint.2013.09.019Zhang, C., Liu, H., & Li, H. (2013). Modeling of Frictional Resistance of a Capsule Robot Moving in the Intestine at a Constant Velocity. Tribology Letters, 53(1), 71-78. doi:10.1007/s11249-013-0244-5Zhang, C., Liu, H., Tan, R., & Li, H. (2012). Modeling of Velocity-dependent Frictional Resistance of a Capsule Robot Inside an Intestine. Tribology Letters, 47(2), 295-301. doi:10.1007/s11249-012-9980-1Woo, S. H., Kim, T. W., Mohy-Ud-Din, Z., Park, I. Y., & Cho, J.-H. (2011). Small intestinal model for electrically propelled capsule endoscopy. BioMedical Engineering OnLine, 10(1), 108. doi:10.1186/1475-925x-10-108Sliker, L. J., & Rentschler, M. E. (2012). The Design and Characterization of a Testing Platform for Quantitative Evaluation of Tread Performance on Multiple Biological Substrates. IEEE Transactions on Biomedical Engineering, 59(9), 2524-2530. doi:10.1109/tbme.2012.2205688Sánchez-Diaz, C., Senent-Cardona, E., Pons-Beltran, V., Santonja-Gimeno, A., & Vidaurre, A. (2018). Endoworm: A new semi-autonomous enteroscopy device. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 232(11), 1137-1143. doi:10.1177/0954411918806330Persson, B. N. J., & Spencer, N. D. (1999). Sliding Friction: Physical Principles and Applications. Physics Today, 52(1), 66-68. doi:10.1063/1.882557Gerson, L. B., Flodin, J. T., & Miyabayashi, K. (2008). Balloon-assisted enteroscopy: technology and troubleshooting. Gastrointestinal Endoscopy, 68(6), 1158-1167. doi:10.1016/j.gie.2008.08.012Glozman, D., Hassidov, N., Senesh, M., & Shoham, M. (2010). A Self-Propelled Inflatable Earthworm-Like Endoscope Actuated by Single Supply Line. IEEE Transactions on Biomedical Engineering, 57(6), 1264-1272. doi:10.1109/tbme.2010.2040617Baek, N.-K., Sung, I.-H., & Kim, D.-E. (2004). Frictional resistance characteristics of a capsule inside the intestine for microendoscope design. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 218(3), 193-201. doi:10.1243/095441104323118914Kwon, J., Cheung, E., Park, S., & Sitti, M. (2006). Friction enhancement via micro-patterned wet elastomer adhesives on small intestinal surfaces. Biomedical Materials, 1(4), 216-220. doi:10.1088/1748-6041/1/4/007Kim, B., Lee, S., Park, J. H., & Park, J.-O. (2005). Design and Fabrication of a Locomotive Mechanism for Capsule-Type Endoscopes Using Shape Memory Alloys (SMAs). IEEE/ASME Transactions on Mechatronics, 10(1), 77-86. doi:10.1109/tmech.2004.842222Terry, B. S., Lyle, A. B., Schoen, J. A., & Rentschler, M. E. (2011). Preliminary Mechanical Characterization of the Small Bowel for In Vivo Robotic Mobility. Journal of Biomechanical Engineering, 133(9). doi:10.1115/1.400516
Catching the Sugars: Electrochemical Aptasensors for the Detection of Cancer-Related Glycosylation Changes in Prostate-Specific Antigen
Prostate-specific Antigen (PSA) is the biomarker that is used for prostate cancer (PCa) detection, although its lack of specificity results in a high rate of false-positives and many unnecessary biopsies. Therefore, there is a need for more specific cancer biomarkers for PCa. Recent studies have shown that the aberrant glycosylation of proteins is a common feature of the presence of cancer. In the case of prostate cancer, there are changes in core-fucose and sialic acids in the glycan structure of PSA. In this work, we describe two different strategies to direct the selection of aptamers toward the glycans of PSA. From these strategies, we identified two aptamers (PSA-1 and PSAG-1) that bind to the glycan structure of PSA with high affinity. Both aptamers were applied in the design of electrochemical aptasensors, in sandwich and direct formats, in order to detect the changes in the glycosylation of PSA. The sensors responded to different levels of PSA in serum, and they showed higher potential to discriminate clinically-meaningful PCa than the ELISA (Enzyme-linked immunosorbent assay) test used in hospitals (reducing the number of false positives), although validation on more samples is needed
A hybrid analysis of LBSN data to early detect anomalies in crowd dynamics
Undoubtedly, Location-based Social Networks (LBSNs) provide an interesting source of geo-located data that we have previously used to obtain patterns of the dynamics of crowds throughout urban areas. According to our previous results, activity in LBSNs reflects the real activity in the city. Therefore, unexpected behaviors in the social media activity are a trustful evidence of unexpected changes of the activity in the city. In this paper we introduce a hybrid solution to early detect these changes based on applying a combination of two approaches, the use of entropy analysis and clustering techniques, on the data gathered from LBSNs. In particular, we have performed our experiments over a data set collected from Instagram for seven months in New York City, obtaining promising results.This work is funded by: the European Regional Development Fund (ERDF) and the Galician Regional Government under agreement for funding the Atlantic Research Center for Information and Communication Technologies (AtlantTIC), Spain, the Spanish Ministry of Economy and Competitiveness under the National Science Program (TEC2014-54335-C4-3-R, TEC2014-54335-C4-2-R, TEC2017-84197-C4-3-R and TEC2017-84197-C4-2-R), and by the Madrid Regional Government eMadrid Excellence Network, Spain (S2013/ICE-2715)
Imaging ultrafast dynamical diffraction wavefronts in strained Si with coherent X-rays
Dynamical diffraction effects in single crystals produce highly monochromatic
parallel X-ray beams with a mutual separation of a few micrometer and a
time-delay of a few fs -the so-called echoes. This ultrafast diffraction effect
is used at X-ray Free Electron Lasers in self-seeding schemes to improve beam
monochromaticity. Here, we present a coherent X-ray imaging measurement of
echoes from Si crystals and demonstrate that a small surface strain can be used
to tune their temporal delay. These results represent a first step towards the
ambitious goal of strain-tailoring new X-ray optics
“Aplicación de estrategias pedagógicas que promuevan el uso responsable del agua en los estudiantes de los grados segundo y tercero del colegio Fernando Mazuera Villegas sede c”
Este proyecto de intervención está dirigido a implementar estrategias pedagógicas
en el aula para aprender a hacer uso responsable del agua, crear sentido de
pertenencia con la institución y con los recursos que nos brinda la naturaleza,
crear hábitos del cuidado y de la responsabilidad que tenemos con el medio
ambiente a partir de la planeación y ejecución de diferentes actividades con los
estudiantes de los grados segundo y tercero de primaria del IED Fernando
Mazuera Villegas, ubicado en la localidad 7 de Bosa, problemáticas que se
presentan por el desperdicio descontrolado del agua en la institución durante la
realización de actividades de rutina como protocolo en el lavado de manos, por
grifos y baterías de baños en mal estado y aseo de la institución por parte del
personal de servicios generales, entre otros.
El carácter geográfico del proyecto permite diseñar y aplicar cuatro fases
temáticas planeadas desde los intereses particulares de los niños así. Fase uno
inauguración y sensibilización de los niños por medio de la canción al “agua es
vida cuídala”. Fase dos: cine talleres de reflexión y la conformación del club
defensores del agua con los estudiantes líderes de cada grupo. Fase tres: salida
Ecológica por medio del recorrido al humedal Tibanica, ubicado en la localidad de
Bosa, elaboración y aplicación de la carilla Educativa “El cuidado del agua,
compromiso de todos”. Fase cuatro actuando y ejecutando, actividades a partir del
cuento, producción escrita y representación teatral y el diseño de un sistema de
recolección de aguas lluvias para la instituciónThis intervention project is aimed at implementing pedagogical strategies
in the classroom to learn how to use water responsibly, create a sense of
belonging to the institution and to the resources provided by nature,
create habits of care and responsibility that we have with the environment
environment from the planning and execution of different activities with the
second and third grade students of IED Fernando
Mazuera Villegas, located in locality 7 of Bosa, problems that are
presented by the uncontrolled waste of water in the institution during the
carrying out routine activities such as hand washing protocol, for
faucets and batteries in bathrooms in poor condition and cleaning of the institution by the
general service staff, among others.
The geographical nature of the project allows for the design and application of four phases
Themes planned from the particular interests of children as well. phase one
inauguration and awareness of children through the song to "water is
life take care of it”. Phase two: cinema reflection workshops and the formation of the club
advocates for water with the student leaders from each group. Phase three: departure
Ecological through the tour to the Tibanica wetland, located in the town of
Bosa, elaboration and application of the Educational page “The care of the water,
everyone's commitment. Phase four acting and executing, activities from the
story, written production and theatrical performance and the design of a system of
rainwater harvesting for the institutio
Association between gamma glutamyl transpeptidase to HDL-cholesterol (GGT/HDL-C) ratio and metabolic syndrome resolution after sleeve gastrectomy
OBJECTIVE: To evaluate the association between GGT/HDL-C ratio and resolution of MetS in adults after sleeve gastrectomy (SG). METHODS: We conducted a retrospective cohort study using secondary data from a Peruvian bariatric center. The study population consisted of adults aged 18 and above who underwent laparoscopic SG and were diagnosed with MetS prior to the surgery. The main outcome measured was MetS resolution 6 months post-surgery and the exposure variable was the GGT/HDL-C ratio. RESULTS: We analyzed 137 patients with a mean age of 38.9 ± 10.9 years; 64.2% were females. The median GGT/HDL-C ratio was 1.1 [0.7 - 1.5], and 83.9% of patients experienced resolution of MetS. Furthermore, both the middle tertile of GGT/HDL-C (aRR: 1.28; 95% CI: 1.04 - 1.58; p = .019) and the lowest tertile (aRR: 1.27; 95% CI: 1.01 - 1.60; p = .038) showed a significant association with the resolution of MetS. CONCLUSION: Eight out of 10 patients undergoing SG experience resolution of MetS within 6 months after surgery. Patients in the middle and lower tertiles of the GGT/HDL-C were more likely to achieve this outcome. Therefore, the GGT/HDL-C ratio should be considered a valuable and efficient biomarker for preoperative assessment of bariatric surgery candidates
- …