6,680 research outputs found

    Infrared heterodyne radiometer for airborne atmospheric transmittance measurements

    Get PDF
    An infrared heterodyne radiometer (IHR) was used to measure atmospheric transmittance at selected hydrogen fluoride (2.7 micrometer) and deuterium fluoride (3.8 micrometer) laser transitions. The IHR was installed aboard a KC-135 aircraft for an airborne atmospheric measurements program that used the sun as a backlighting source for the transmission measurements. The critical components are: a wideband indium antimonide (1nSb) photomixer, a CW HF/DF laser L0, a radiometric processor, and a 1900 K blackbody reference source. The measured heterodyne receiver sensitivity (NEP) is 1.3 x 10 to the -19th power W/Hz, which yields a calculated IHR temperature resolution accuracy of delta I sub S/-3 sub S = 0.005 for a source temperature of 1000 K and a total transmittance of 0.5. Measured atmospheric transmittance at several wavelengths and aircraft altitudes from 9.14 km (30,000 ft) to 13.72 km (45,000 ft) were obtained during the measurements program and have been compared with values predicted by the AFGL Atmospheric Line Parameter Compilation

    Elimination of pain improves specificity of clinical diagnostic criteria for adult chronic rhinosinusitis

    Get PDF
    Objective Determine whether the elimination of pain improves accuracy of clinical diagnostic criteria for adult chronic rhinosinusitis. Study Design Retrospective cohort study. Methods History, symptoms, nasal endoscopy, and computed tomography (CT) results were analyzed for 1,186 adults referred to an academic otolaryngology clinic with presumptive diagnosis of chronic rhinosinusitis. Clinical diagnosis was rendered using the 1997 Rhinosinusitis Taskforce (RSTF) Guidelines and a modified version eliminating facial pain, ear pain, dental pain, and headache. Results Four hundred seventy-nine subjects (40%) met inclusion criteria. Among subjects positive by RSTF guidelines, 45% lacked objective evidence of sinonasal inflammation by CT, 48% by endoscopy, and 34% by either modality. Applying modified RSTF diagnostic criteria, 39% lacked sinonasal inflammation by CT, 38% by endoscopy, and 24% by either modality. Using either abnormal CT or endoscopy as the reference standard, modified diagnostic criteria yielded a statistically significant increase in specificity from 37.1% to 65.1%, with a nonsignificant decrease in sensitivity from 79.2% to 70.3%. Analysis of comorbidities revealed temporomandibular joint disorder, chronic cervical pain, depression/anxiety, and psychiatric medication use to be negatively associated with objective inflammation on CT or endoscopy. Conclusion Clinical diagnostic criteria overestimate the prevalence of chronic rhinosinusitis. Removing facial pain, ear pain, dental pain, and headache increased specificity without a concordant loss in sensitivity. Given the high prevalence of sinusitis, improved clinical diagnostic criteria may assist primary care providers in more accurately predicting the presence of inflammation, thereby reducing inappropriate antibiotic use or delayed referral for evaluation of primary headache syndromes. Level of Evidence4. Laryngoscope, 127:1011-1016, 201

    Overview of the TOPEX/Poseidon Platform Harvest Verification Experiment

    Get PDF
    An overview is given of the in situ measurement system installed on Texaco's Platform Harvest for verification of the sea level measurement from the TOPEX/Poseidon satellite. The prelaunch error budget suggested that the total root mean square (RMS) error due to measurements made at this verification site would be less than 4 cm. The actual error budget for the verification site is within these original specifications. However, evaluation of the sea level data from three measurement systems at the platform has resulted in unexpectedly large differences between the systems. Comparison of the sea level measurements from the different tide gauge systems has led to a better understanding of the problems of measuring sea level in relatively deep ocean. As of May 1994, the Platform Harvest verification site has successfully supported 60 TOPEX/Poseidon overflights

    Small Aircraft Data Distribution System

    Get PDF
    The CARVE Small Aircraft Data Distribution System acquires the aircraft location and attitude data that is required by the various programs running on a distributed network. This system distributes the data it acquires to the data acquisition programs for inclusion in their data files. It uses UDP (User Datagram Protocol) to broadcast data over a LAN (Local Area Network) to any programs that might have a use for the data. The program is easily adaptable to acquire additional data and log that data to disk. The current version also drives displays using precision pitch and roll information to aid the pilot in maintaining a level-level attitude for radar/radiometer mapping beyond the degree available by flying visually or using a standard gyro-driven attitude indicator. The software is designed to acquire an array of data to help the mission manager make real-time decisions as to the effectiveness of the flight. This data is displayed for the mission manager and broadcast to the other experiments on the aircraft for inclusion in their data files. The program also drives real-time precision pitch and roll displays for the pilot and copilot to aid them in maintaining the desired attitude, when required, during data acquisition on mapping lines

    Localized Excitons and Breaking of Chemical Bonds at III-V (110) Surfaces

    Full text link
    Electron-hole excitations in the surface bands of GaAs(110) are analyzed using constrained density-functional theory calculations. The results show that Frenkel-type autolocalized excitons are formed. The excitons induce a local surface unrelaxation which results in a strong exciton-exciton attraction and makes complexes of two or three electron-hole pairs more favorable than separate excitons. In such microscopic exciton "droplets" the electron density is mainly concentrated in the dangling orbital of a surface Ga atom whereas the holes are distributed over the bonds of this atom to its As neighbors thus weakening the bonding to the substrate. This finding suggests the microscopic mechanism of a laser-induced emission of neutral Ga atoms from GaAs and GaP (110) surfaces.Comment: submitted to PRL, 10 pages, 4 figures available upon request from: [email protected]

    Cs-Induced Surface State on GaAs(110)

    Get PDF
    Cesium adsorption on GaAs(110) has been studied by angle-resolved photoemission spectroscopy at room temperature in the submonolayer-coverage regime. We report the observation of a Cs-induced surface state in the vicinity of the surface-Brillouin-zone edge. The possible origin of the state is discussed in relation to recent structural observations. The onset of the Cs-induced surface state can be correlated with the appearance of a second Cs 5p core-level emission feature at ∼0.2 monolayer Cs coverage

    Resistance of sugarcane cultivars to Diataea saccharalis.

    Get PDF
    The objective of this work was to evaluate the ovipositions preference of Diatraea saccharalis and the effect of ten sugarcane cultivars on larval development. Oviposition preference was assessed under greenhouse condition by three releases of couples of moths, with subsequent counting of egg masses and eggs per plant. In order to evaluate the effet of the cultivars on larval development, each plant was infected with about 150 eggs, and, 29 days later, the total number of internodes, number of bored internodes, number of life forms found, larval and pupal weight and length, and the width of larval head capsule were evaluated.Título em português: Resistência de cultivares de cana?de?açúcar a Diatraea saccharalis

    Electronic Band Structure of the Two-Dimensional Surface-State Bands of the (1×1) and (1×2) Phases of Bi/GaSb(110)

    Get PDF
    The surface-state bands of the (1×1) and (1×2) phases of Bi/GaSb(110) have been probed using angle-resolved ultraviolet photoemission spectroscopy with synchrotron radiation. Four Bi-induced surface-state bands have been identified for both the (1×1) and the (1×2) phases. The bands with the lowest binding energies (SI and SII) have been attributed to intrachain bonding in the Bi overlayer and the higher-binding-energy bands (SIII and SIV) to overlayer states involved in the back bonding of the overlayer to the substrate. Based on initial-state dispersion measurements, we conclude that the Bi chains in the epitaxial overlayer remain intact throughout the phase transition. We propose a model for the overlayer structure of the (1×2) phase of Bi/GaSb(110)

    Prospective longitudinal study of coagulation profiles in children with hypoplastic left heart syndrome from stage I through Fontan completion

    Get PDF
    ObjectiveThe risk for thrombosis is increased after the Fontan operation. It is unknown whether children with univentricular heart disease have an intrinsic coagulation anomaly or acquire a defect in coagulation during the course of the staged repair. This prospective, longitudinal study evaluated changes in coagulation profiles in a cohort of patients with hypoplastic left heart syndrome from stage I palliation through completion of the Fontan operation.MethodsThirty-seven patients with hypoplastic left heart syndrome were enrolled prospectively, and the concentration of factors II, V, VII, VIII, IX, X, proteins C and S, fibrinogen, antithrombin, serum albumin, and liver enzymes were measured before stage I palliation (mean age 4 ± 2 days), before bidirectional Glenn (mean age 5.9 ± 1.8 months), before the Fontan procedure (mean age 27.1 ± 6.6 months), and after the Fontan procedure (mean age 49 ± 17.6months). Healthy children were used as age-matched controls for coagulation factors. Demographic, hemodynamic variables, and elapsed time after the Fontan procedure were evaluated as possible predictors of coagulation abnormalities.ResultsSignificantly lower levels of both procoagulation and anticoagulation factors were demonstrated through to completion of the Fontan procedure. After the Fontan procedure, there was a significantly higher factor VIII level (P < .005) but no correlation with hemodynamic variables or liver function.ConclusionThis longitudinal study in patients with identical cardiac disease and staged surgical procedures confirms the increase in factor VIII level after the Fontan procedure. This is an acquired defect, and although the cause remains to be determined, monitoring factor VIII levels after the Fontan operation could indicate a subset of patients at risk for thrombosis

    Prospective longitudinal study of coagulation profiles in children with hypoplastic left heart syndrome from stage I through Fontan completion

    Get PDF
    ObjectiveThe risk for thrombosis is increased after the Fontan operation. It is unknown whether children with univentricular heart disease have an intrinsic coagulation anomaly or acquire a defect in coagulation during the course of the staged repair. This prospective, longitudinal study evaluated changes in coagulation profiles in a cohort of patients with hypoplastic left heart syndrome from stage I palliation through completion of the Fontan operation.MethodsThirty-seven patients with hypoplastic left heart syndrome were enrolled prospectively, and the concentration of factors II, V, VII, VIII, IX, X, proteins C and S, fibrinogen, antithrombin, serum albumin, and liver enzymes were measured before stage I palliation (mean age 4 ± 2 days), before bidirectional Glenn (mean age 5.9 ± 1.8 months), before the Fontan procedure (mean age 27.1 ± 6.6 months), and after the Fontan procedure (mean age 49 ± 17.6months). Healthy children were used as age-matched controls for coagulation factors. Demographic, hemodynamic variables, and elapsed time after the Fontan procedure were evaluated as possible predictors of coagulation abnormalities.ResultsSignificantly lower levels of both procoagulation and anticoagulation factors were demonstrated through to completion of the Fontan procedure. After the Fontan procedure, there was a significantly higher factor VIII level (P < .005) but no correlation with hemodynamic variables or liver function.ConclusionThis longitudinal study in patients with identical cardiac disease and staged surgical procedures confirms the increase in factor VIII level after the Fontan procedure. This is an acquired defect, and although the cause remains to be determined, monitoring factor VIII levels after the Fontan operation could indicate a subset of patients at risk for thrombosis
    corecore