    Imaging performance of a dedicated radiation transparent RF coil on a 1.0 Tesla inline MRI-linac

    Get PDF
    This work describes the first imaging studies on a 1.0 Tesla inline MRI-Linac using a dedicated transmit/receive RF body coil that has been designed to be completely radio transparent and provide optimum imaging performance over a large patient opening.
 Methods: A series of experiments was performed on the MRI-Linac to investigate the performance and imaging characteristics of a new dedicated volumetric RF coil: (1) numerical electromagnetic simulations were used to measure transmit efficiency in two patient positions; (2) image quality metrics of signal-to-noise ratio (SNR), ghosting and uniformity were assessed in a large diameter phantom with no radiation beam; (3) radiation induced effects were investigated in both the raw data (k-space) and image sequences acquired with simultaneous irradiation; (4) radiation dose was measured with and without image acquisition; (5) RF heating was studied using an MR-compatible fluoroptic thermometer and; (6) the in vivo image quality and versatility of the coil was demonstrated in normal healthy subjects for both supine and standing positions.
 Results: Daily phantom measurements demonstrated excellent imaging performance with stable SNR over a period of 3 months (42.6 ± 0.9). Simultaneous irradiation produced no statistical change in image quality (p>0.74) and no interference in raw data for a 20 20 cm radiation field. The coil was found to be efficient over large volumes and negligible RF heating was observed. Volunteer scans acquired in both supine and standing positions provided artefact free images with good anatomical visualisation.
 Conclusions: The first completely radio transparent RF coil for use on a 1.0 Tesla MRI-Linac has been described. There is no impact on either the imaging or dosimetry performance with a simultaneous radiation beam. The open design enables imaging and radiotherapy guidance in a variety of positons.&#13

    Optimized interferometric encoding of presaturated TurboFLASH B1 mapping for parallel transmission MRI at 7 T : Preliminary application for quantitative T1 mapping in the spinal cord

    No full text
    International audiencePurpose: The acquisition of accurate B1 maps is critical for parallel transmit techniques (pTx). The presaturated turboFLASH (satTFL) method has been widely used in combination with interferometric encoding to provide robust and fast B1 maps. However, typical encodings, mostly evaluated on brain, do not necessarily fit all coils and organs. In this work, we evaluated and improved the accuracy of the satTFL for cervical spine at 7 T, proposing a novel interferometric encoding optimization. The benefits of such improvements were investigated in an exploratory study of quantitative T1 mapping with pTx-MP2RAGE. Methods: Global optimization of interferometric encoding was implemented by simulating the ability of the satTFL to reconstruct B1 maps, with varying encoding and inclusion of complex noise, inside a region of interest covering the cervical spine. The performance of satTFL before and after optimization was compared to actual flip angle imaging. Optimized and non-optimized B1 maps were then used to calculate pTx pulses for MP2RAGE T1 mapping. Results: Interferometric encoding optimization resulted in satTFL closer to actual flip angle imaging, with substantial gain of signal in regions where non-optimized satTFL could fail. T1 maps measured with non-adiabatic pTx pulses were closer to standard non-pTx results (which used adiabatic pulses) when using optimized-satTFL, with substantially lower specific absorption rate. Conclusion: Optimization of the satTFL interferometric encoding improves B1 maps in the spinal cord, in particular in low SNR regions. A linear correction of the satTFL was additionally shown to be required. The method was successfully used for quantitative phantom and in vivo T1 mapping, showing improved results compared to non-optimized satTFL thanks to improved pTx-pulse generation

    An open 8-channel parallel transmission coil for static and dynamic 7T MRI of the knee and ankle joints at multiple postures

    No full text
    Purpose: We present the initial in vivo imaging results of an open architecture eight-channel parallel transmission (pTx) transceive radiofrequency (RF) coil array that was designed and constructed for static and dynamic 7T MRI of the knee and ankle joints. Methods: The pTx coil has a U-shaped dual-row configuration (200 mm overall length longitudinally) that allows static and dynamic imaging of the knee and ankle joints at various postures and during active movements. This coil structure, in combination with B shimming, allows flexible configuration of B transmit profiles, with good homogeneity over 120-mm regions of interest. This coil enabled high-resolution gradient echo (e.g., 3D dual-echo steady state [DESS] and 3D multiecho data image combination [MEDIC]) and turbo spin echo (TSE) imaging (e.g., with proton density weighting [PDw], PDw with fat saturation, and T and T weightings) with local RF energy absorption rates well below regulatory limits. Results: High-resolution 2D and 3D image series (e.g., 0.3 mm in-plane resolution for TSE, 0.47 mm isotropic for DESS and MEDIC) were obtained from the knee and ankle joints with excellent tissue contrast. Dynamic imaging during continuous knee and ankle flexion-extension cycles were successfully acquired. Conclusion: The new open pTx coil array provides versatility for high-quality static and dynamic MRI of the knee and ankle joints at 7T. Magn Reson Med 79:1804–1816, 2018

    Magnetic resonance-electrical properties tomography by directly solving Maxwell’s Curl Equations

    No full text
    Magnetic Resonance-Electrical Properties Tomography (MR-EPT) is a method to reconstruct the electrical properties (EPs) of bio-tissues from the measured radiofrequency (RF) field in Magnetic Resonance Imaging (MRI). Current MR-EPT approaches reconstruct the EP profile by solving a second-order partial differential wave equation problem, which is sensitive to noise and can induce large reconstruction artefacts near tissue boundaries and areas with inaccurate field measurements. In this paper, a novel MR-EPT approach is proposed, which is based on a direct solution to Maxwell's curl equations. The distribution of EPs is calculated by iteratively fitting the RF field calculated by the finite-difference-time-domain (FDTD) technique to the measured values. To solve the time-consuming problem of the iterative fitting, a graphics processing unit (GPU) is used to accelerate the FDTD technique to process the field calculation kernel. The new EPT method was evaluated by investigating a numerical head phantom, and it was found that EP values can be accurately calculated and were relatively insensitive to simulated RF field errors. The feasibility of the proposed method was further validated using phantom-based experimental data collected from a 9.4 Tesla (T) Magnetic Resonance Imaging (MRI) system. The results also indicated that more accurate EP values could be reconstructed from the new method compared with conventional methods. Moreover, even in the absence of phase information of the RF field, the proposed approach is still capable of offering robust EPT solutions, thus having improved practicality for potential clinical applications