21 research outputs found

    Development and validation of a liquid chromatography coupled to tandem mass spectrometry method for the monitoring of temsavir plasma concentrations in people living with HIV.

    Get PDF
    A majority of people living with HIV (PLWH) now have access to HIV treatment with high antiviral potency and favorable tolerability profile. However, in some treatment experienced PLWH viral strains resistant to major current classes of antiretrovirals have emerged, usually due to periods with continued virus replication in the presence of failing drug regimens and thus selection pressure. In such context, new treatment options are therefore needed. Fostemsavir (RUKOBIA®) is the prodrug of temsavir, a first-in-class oral attachment inhibitor approved for the treatment of heavily treatment-experienced adults with multidrug-resistant HIV-1 infection. In this case RUKOBIA® is part of a complex regimen of antiretroviral drugs, often in addition to other drugs for chronic co-morbidities (e.g., heart disease, diabetes mellitus, hepatic and renal impairment, etc). In such a multi-drug regimen context, therapeutic drug monitoring (TDM) of temsavir can be necessary to exclude or adjust for relevant drug-drug interactions. A highly selective assay by liquid chromatography method coupled to tandem mass spectrometry (LC-MS/MS) was therefore developed for the quantification of temsavir in human plasma. A convenient sample preparation using protein precipitation with acetonitrile followed by supernatant dilution was carried out. Temsavir and fostemsavir were separated in less than 2 min using a multi-step UPLC gradient, thus ensuring adequate quantification of temsavir. The assay for the quantification of temsavir was extensively validated over the large range of clinically relevant concentrations from 1 to 10,000 ng/mL, in accordance with international bioanalytical method guidelines. The method achieves excellent performance in terms of trueness (99.7 - 105.3%), repeatability and intermediate precision (both from 1.6% to 5.8%). This LC-MS/MS method is now part of the routine analyses of the Laboratory of the Service of Clinical Pharmacology of Lausanne (CHUV), Switzerland, as an integrated part of our general TDM Service for antiretrovirals

    Possibilities of retention modeling and computer assisted method development in supercritical fluid chromatography

    Full text link
    The multi-modal retention mechanism in supercritical fluid chromatography (SFC) results in a non-linear dependency of log(k) on the fraction of organic solvent ϕ and log(ϕ). In the present study, the possibility of retention modeling for method development purposes in SFC was investigated, considering several non-linear isocratic relationships. Therefore, both isocratic and gradient runs were performed, involving different column chemistries and analytes possessing diverse physico-chemical properties. The isocratic retention data of these compounds could be described accurately using the non-linear retention models typically used in HILIC and reversed-phase LC. The interconversion between isocratic and gradient retention data was found to be less straightforward than in RPLC and HILIC because of pressure effects. The possibility of gradient predictions using gradient scouting runs to estimate the retention parameters was investigated as well, showing that predictions for other gradients with the same starting conditions were acceptable (always below 5%), whereas prediction errors for gradients with a different starting condition were found to be highly dependent on the compound. The second part of the study consisted of the gradient optimization of two pharmaceutical mixtures (one involving atorvastatin and four related impurities, and one involving a 16 components mixture including eight drugs and their main phase I metabolites). This could be done via individual retention modeling based on gradient scouting runs. The best linear gradient was found via a grid search and the best multi-segment gradient via the previously published one-segment-per-component search. The latter improved the resolution between the critical pairs for both mixtures, while still giving accurate prediction errors (using the same starting concentrations as the gradient scouting runs used to build the model). The optimized separations were found in less than 3. h and 8. h of analysis time (including equilibration times), respectively. © 2015 Elsevier B.V

    Quel est l'apport de la chromatographie en phase supercritique pour l'analyse antidopage ?

    No full text
    Objectif Évaluer l’utilisation de la chromatographie en phase supercritique (SFC) couplée à la spectrométrie de masse en mode tandem (MS/MS) pour l’analyse antidopage. Méthodes Un large panel de molécules issues de la liste des substances interdites publiée par l’Agence mondiale antidopage (AMA) a été utilisé pour ce travail. Les 200 molécules choisies appartiennent aux classes des diurétiques, bêtabloquants, stimulants, narcotiques, stéroïdes exogènes, cannabinoïdes synthétiques, glucocorticoïdes… Ces substances couvrent une très large gamme de propriétés physico-chimiques (masse moléculaire, polarité, propriétés acido-basiques…). Deux méthodes de criblage, incluant une préparation d’échantillon adaptée, une technique chromatographique de type SFC et une méthode de détection MS/MS, ont été développées pour la détermination de ces agents dopants dans l’urine. Les résultats obtenus ont été systématiquement comparés à ceux obtenus en LC-MS/MS en utilisant la même préparation d’échantillon et le même type de spectromètre de masse, ainsi qu’en GC-MS/MS. Résultats Il apparaît que la SFC-MS/MS offre de nombreux avantages pour l’analyse antidopage par rapport à la LC-MS/MS, à savoir : – très bonne complémentarité à la LC, car la rétention est fondée sur un mode d’interaction différent avec la colonne (basé sur les liaisons hydrogène et non sur l’hydrophobicité des molécules) [1] ; – meilleure rétention des composés polaires (grâce à l’utilisation d’une colonne polaire en SFC) ; – amélioration de la sensibilité MS pour une majorité des substances testées sur des instruments MS/MS d’ancienne génération (pour 39 % des composés, la sensibilité est plus de 10 fois supérieure à celle obtenue en LC-MS/MS), mais gain de sensibilité plus modéré sur des systèmes MS de dernière génération [2] ; – diminution des effets matrices, dû à un mode de rétention orthogonale en SFC par rapport à celui utilisé lors de la préparation d’échantillons ; – vitesse d’analyse équivalente, voire meilleure en SFC-MS/MS, grâce à l’utilisation de colonnes courtes remplies de particules sub-2 μm [3]. Conclusion La SFC-MS/MS apparaît comme une technique prometteuse pour l’analyse d’un grand nombre de substances illicites présentes dans des matrices biologiques. Cette approche chromatographique devrait se développer à l’avenir au sein des laboratoires d’analyse antidopage

    Fast and sensitive supercritical fluid chromatography - tandem mass spectrometry multi-class screening method for the determination of doping agents in urine.

    No full text
    This study shows the possibility offered by modern ultra-high performance supercritical fluid chromatography combined with tandem mass spectrometry in doping control analysis. A high throughput screening method was developed for 100 substances belonging to the challenging classes of anabolic agents, hormones and metabolic modulators, synthetic cannabinoids and glucocorticoids, which should be detected at low concentrations in urine. To selectively extract these doping agents from urine, a supported liquid extraction procedure was implemented in a 48-well plate format. At the tested concentration levels ranging from 0.5 to 5 ng/mL, the recoveries were better than 70% for 48-68% of the compounds and higher than 50% for 83-87% of the tested substances. Due to the numerous interferences related to isomers of steroids and ions produced by the loss of water in the electrospray source, the choice of SFC separation conditions was very challenging. After careful optimization, a Diol stationary phase was employed. The total analysis time for the screening assay was only 8 min, and interferences as well as susceptibility to matrix effect (ME) were minimized. With the developed method, about 70% of the compounds had relative ME within the range ±20%, at a concentration of 1 and 5 ng/mL. Finally, limits of detection achieved with the above-described strategy including 5-fold preconcentration were below 0.1 ng/mL for the majority of the tested compounds. Therefore, LODs were systematically better than the minimum required performance levels established by the World anti-doping agency, except for very few metabolites

    Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

    No full text
    This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents

    UHPLC-MS/MS assay for simultaneous determination of amlodipine, metoprolol, pravastatin, rosuvastatin, atorvastatin with its active metabolites in human plasma, for population-scale drug-drug interactions studies in people living with HIV.

    No full text
    Thanks to highly active antiretroviral treatments, HIV infection is now considered as a chronic condition. Consequently, people living with HIV (PLWH) live longer and encounter more age-related chronic co-morbidities, notably cardiovascular diseases, leading to polypharmacy. As the management of drug-drug interactions (DDIs) constitutes a key aspect of the care of PLWH, the magnitude of pharmacokinetic DDIs between cardiovascular and anti-HIV drugs needs to be more thoroughly characterized. To that endeavour, an UHPLC-MS/MS bioanalytical method has been developed for the simultaneous determination in human plasma of amlodipine, metoprolol, pravastatin, rosuvastatin, atorvastatin and its active metabolites. Plasma samples were subjected to protein precipitation with methanol, followed by evaporation at room temperature under nitrogen of the supernatant, allowing to attain measurable plasma concentrations down to sub-nanogram per milliliter levels. Stable isotope-labelled analytes were used as internal standards. The five drugs and two metabolites were analyzed using a 6-min liquid chromatographic run coupled to electrospray triple quadrupole mass spectrometry detection. The method was validated over the clinically relevant concentrations ranging from 0.3 to 480 ng/mL for amlodipine, atorvastatin and p-OH-atorvastatin, and 0.4 to 480 ng/mL for pravastatin, 0.5 to 480 ng/mL for rosuvastatin and o-OH-atorvastatin, and 3 to 4800 ng/mL for metoprolol. Validation performances such as trueness (95.4-110.8%), repeatability (1.5-13.4%) and intermediate precision (3.6-14.5%) were in agreement with current international recommendations. Accuracy profiles (total error approach) were lying within the limits of ±30% accepted in bioanalysis. This rapid and robust UHPLC-MS/MS assay allows the simultaneous quantification in plasma of the major currently used cardiovascular drugs and offers an efficient analytical tool for clinical pharmacokinetics as well as DDIs studies

    Population pharmacokinetic modelling to characterize the effect of chronic kidney disease on tenofovir exposure after tenofovir alafenamide administration.

    No full text
    Tenofovir alafenamide is gradually replacing tenofovir disoproxil fumarate, both prodrugs of tenofovir, in HIV prevention and treatment. There is thus an interest in describing tenofovir pharmacokinetics (PK) and its variability in people living with HIV (PLWH) under tenofovir alafenamide in a real-life setting. To characterize the usual range of tenofovir exposure in PLWH receiving tenofovir alafenamide, while assessing the impact of chronic kidney disease (CKD). We conducted a population PK analysis (NONMEM®) on 877 tenofovir and 100 tenofovir alafenamide concentrations measured in 569 PLWH. Model-based simulations allowed prediction of tenofovir trough concentrations (Cmin) in patients having various levels of renal function. Tenofovir PK was best described using a one-compartment model with linear absorption and elimination. Creatinine clearance (CLCR, estimated according to Cockcroft and Gault), age, ethnicity and potent P-glycoprotein inhibitors were statistically significantly associated with tenofovir clearance. However, only CLCR appeared clinically relevant. Model-based simulations revealed 294% and 515% increases of median tenofovir Cmin in patients with CLCR of 15-29 mL/min (CKD stage 3), and less than 15 mL/min (stage 4), respectively, compared with normal renal function (CLCR = 90-149 mL/min). Conversely, patients with augmented renal function (CLCR > 149 mL/min) had a 36% decrease of median tenofovir Cmin. Kidney function markedly affects circulating tenofovir exposure after tenofovir alafenamide administration in PLWH. However, considering its rapid uptake into target cells, we suggest only a cautious increase of tenofovir alafenamide dosage intervals to 2 or 3 days only in case of moderate or severe CKD, respectively

    Development and validation of a multiplex UHPLC-MS/MS method for the determination of the investigational antibiotic against multi-resistant tuberculosis macozinone (PBTZ169) and five active metabolites in human plasma.

    Get PDF
    The emergence of Mycobacterium tuberculosis strains resistant to current first-line antibiotic regimens constitutes a major global health threat. New treatments against multidrug-resistant tuberculosis (MDR-TB) are thus eagerly needed in particular in countries with a high MDR-TB prevalence. In this context, macozinone (PBTZ169), a promising drug candidate with an unique mode of action and highly potent in vitro tuberculocidal properties against MDR Mycobacterium strains, has now reached the clinical phase and has been notably tested in healthy male volunteers in Switzerland. To that endeavor, a multiplex UHPLC-MS/MS method has been developed for the sensitive and accurate human plasma levels determination of PBTZ169 along with five metabolites retaining in vitro anti-TB activity. Plasma protein precipitation with methanol was carried out as a simplified sample clean-up procedure followed by direct injection of the undiluted supernatant for the bioanalysis of the six analytes within 5 min, using 1.8 μm reversed-phase chromatography coupled to triple quadrupole mass spectrometry employing electrospray ionization in the positive mode. Stable isotopically-labelled PBTZ169 was used as internal standard (ISTD), while metabolites could be reliably quantified using two unlabeled chemical analogues selected as ISTD from a large in-house analogous compounds library. The overall methodology was fully validated according to current recommendations (FDA, EMEA) for bioanalytical methods, which include selectivity, carryover, qualitative and quantitative matrix effect, extraction recovery, process efficiency, trueness, precision, accuracy profiles, method and instrument detection limits, integrity to dilution, anticoagulant comparison and short- and long-term stabilities. Stability studies on the reduced metabolite H2-PBTZ169 have shown no significant impact on the actual PBTZ169 concentrations determined with the proposed assay. This simplified, rapid, sensitive and robust methodology has been applied to the bioanalysis of human plasma samples collected within the frame of a phase I clinical study in healthy volunteers receiving PBTZ169
    corecore