158 research outputs found

    Prospective Evaluation of Ultrasonic Surgical Dissectors in Hepatic Resection: A Cooperative Multicenter Study

    Get PDF
    Blood loss is the major cause of postoperative mortality and morbidity associated with hepatic resection. A prospective multicenter study was conducted to determine if ultrasonic dissectors (USD) were useful in hepatic resection and could reduce this hemorrhagic risk. Forty-seven hepatic resections were performed in 42 consecutive patients during a two month period in 11 public, surgical centers. Twenty-one patients had primary or secondary malignancies, six had benign tumors, two had biliary cysts, one had cholangiocarcinoma, one had Caroli’s disease, and 11 had hydatid cysts of the liver. Two different USD devices were evaluated (CUSA System-Lasersonics and NIIC-DX 101 T). The hepatic resections tested included a wide range of procedures. Each surgeon had the possibility of choosing between the USD and his own usual technique for each operative step and according to local conditions. The average volume of blood infused, irrespective of the underlying pathology or the procedure performed, was 1.0 L (range 0-4.8 L). Fourteen patients required no transfusions. No operative or immediate postoperative deaths were recorded. Five major complications, all unrelated to the use of the USD, developed in three patients. Access to intra and extraparenchymal arterial and venous tributaries and particularly the control of the hepatic veins were facilitated by USD. While transection of hepatic parenchyma was neither easier nor faster than with conventional techniques, it was found to be less hemorrhagic. Overall appraisal was expressed on an analog scale; the USD was found to be helpful or very helpful in 75 percent of all resections. With regard to the pathology being treated, total or partial excision of hydatid cysts was greatly enhanced by the use of the USD while this benefit was not found for wedge resections of other hepatic lesions. With regard to user friendliness and maintenance, the NIIC-DX 101 T device was preferred. We conclude that the USD facilitates formal hepatic resections. Converging opinions emerging from various surgical centers reinforce this conclusion

    Initial Experiences with Laparoscopy-assisted and Total Laparoscopy for Anatomical Liver Resection: A Preliminary Study

    Get PDF
    Although laparoscopic surgery has become more popular, its technical difficulties have limited the applications of this technique to liver surgery. We report here on our experience with liver resection with using the laparoscopy-assisted (Lap-Assist) and total laparoscopic (Total-Lap) methods. From April 2001 to June 2003, a total of 20 laparoscopic anatomical resections of the liver were retrospectively reviewed. These were comprised of 10 cases in which the Lap-Assist method was used (these were performed during the early study period), and 10 cases in which the Total-Lap was used (these were done in the later study period). In the Lap-Assist group, the following resections were performed: 7 cases of left lateral sectionectomy, a case of left hemihepatectomy, a case of right hemihepatectomy and a case of open conversion. In the Total-Lap group, 6 cases of left hemihepatectomy and 4 cases of left lateral sectionectomy were performed. The sizes of the incisions were 8.7 cm and 4.6 cm, respectively, (p=0.000). There were no differences in the operation times, the transfusion amounts, the starting days of the patients' diets, the complication rates or the durations of the hospital stay between the two groups. Both the laparoscopy-assisted method and the total laparoscopic method are feasible to use for performing anatomical liver resection

    Exploring dynamic lighting, colour and form with smart textiles

    Get PDF
    This paper addresses an ongoing research, aiming at the development of smart textiles that transform the incident light that passes through them – light transmittance – to design dynamic light without acting upon the light source. A colour and shape change prototype was developed with the objective of studying textile changes in time; to explore temperature as a dynamic variable through electrical activation of the smart materials and conductive threads integrated in the textile substrate; and to analyse the relation between textile chromic and morphologic behaviour in interaction with light. Based on the experiments conducted, results have highlighted some considerations of the dynamic parameters involved in the behaviour of thermo-responsive textiles and demonstrated design possibilities to create interactive lighting scenarios.This work is supported by FEDER funds through the Operational Programme for Competitiveness Factors – COMPETE and National Funds through FCT – Foundation for Science and Technology within the scope of the projects SFRH/BD/87196/2012, POCI-01-0145-FEDER-007136 and UID/CTM/00264. The authors also like to acknowledge Smart Textiles Design Lab for the support on the prototype development.info:eu-repo/semantics/publishedVersio

    Perioperative outcome of laparoscopic left lateral liver resection is improved by using a bioabsorbable staple line reinforcement material in a porcine model

    Get PDF
    Hypothesis Laparoscopic liver surgery is significantly limited by the technical difficulty encountered during transection of substantial liver parenchyma, with intraoperative bleeding and bile leaks. This study tested whether the use of a bioabsorble staple line reinforcement material would improve outcome during stapled laparoscopic left lateral liver resection in a porcine model. Study design A total of 20 female pigs underwent stapled laparoscopic left lateral liver resection. In group A (n = 10), the stapling devices were buttressed with a bioabsorbable staple line reinforcement material. In group B (n = 10), standard laparoscopic staplers were used. Operative data and perioperative complications were recorded. Necropsy studies and histopathological analysis were performed at 6 weeks. Data were compared between groups with the Student's t-test or the chi-square test. Results Operating time was similar in the two groups (64 +/- 11 min in group A versus 68 +/- 9 min in group B, p = ns). Intraoperative blood loss was significantly higher in group B (185 +/- 9 mL versus 25 +/- 5 mL, p <0.05). There was no mortality. There was no morbidity in the 6-week follow-up period; however, two animals in group B had subphrenic bilomas (20%) at necropsy. At necropsy, methylene blue injection via the main bile duct revealed leakage from the biliary tree in four animals in group B and none in group A (p <0.05). Histopathological examination of the resection site revealed minor abnormalities in group A while animals in group B demonstrated marked fibrotic changes and damaged vascular and biliary endothelium. Conclusion Use of a bioabsorbable staple line reinforcement material reduces intraoperative bleeding and perioperative bile leaks during stapled laparoscopic left lateral liver resection in a porcine model

    Evolution of laparoscopic left lateral sectionectomy without the Pringle maneuver: through resection of benign and malignant tumors to living liver donation

    Get PDF
    BACKGROUND: Laparoscopic left lateral sectionectomy (LLS) has gained popularity in its use for benign and malignant tumors. This report describes the evolution of the authors' experience using laparoscopic LLS for different indications including living liver donation. METHODS: Between January 2004 and January 2009, 37 consecutive patients underwent laparoscopic LLS for benign, primary, and metastatic liver diseases, and for one case of living liver donation. Resection of malignant tumors was indicated for 19 (51%) of the 37 patients. RESULTS: All but three patients (deceased due to metastatic cancer disease) are alive and well after a median follow-up period of 20 months (range, 8-46 months). Liver cell adenomas (72%) were the main indication among benign tumors, and colorectal liver metastases (84%) were the first indication of malignancy. One case of live liver donation was performed. Whereas 16 patients (43%) had undergone a previous abdominal surgery, 3 patients (8%) had LLS combined with bowel resection. The median operation time was of 195 min (range, 115-300 min), and the median blood loss was of 50 ml (range, 0-500 ml). Mild to severe steatosis was noted in 7 patients (19%) and aspecific portal inflammation in 11 patients (30%). A median free margin of 5 mm (range, 5-27 mm) was achieved for all cancer patients. The overall recurrence rate for colorectal liver metastases was of 44% (7 patients), but none recurred at the surgical margin. No conversion to laparotomy was recorded, and the overall morbidity rate was 8.1% (1 grade 1 and 2 grade 2 complications). The median hospital stay was 6 days (range, 2-10 days). CONCLUSIONS: Laparoscopic LLS without portal clamping can be performed safely for cases of benign and malignant liver disease with minimal blood loss and overall morbidity, free resection margins, and a favorable outcome. As the ultimate step of the learning curve, laparoscopic LLS could be routinely proposed, potentially increasing the donor pool for living-related liver transplantation

    Staphylococcus aureus infective endocarditis versus bacteremia strains: Subtle genetic differences at stake

    Get PDF
    AbstractInfective endocarditis (IE)(1) is a severe condition complicating 10–25% of Staphylococcus aureus bacteremia. Although host-related IE risk factors have been identified, the involvement of bacterial features in IE complication is still unclear. We characterized strictly defined IE and bacteremia isolates and searched for discriminant features. S. aureus isolates causing community-acquired, definite native-valve IE (n=72) and bacteremia (n=54) were collected prospectively as part of a French multicenter cohort. Phenotypic traits previously reported or hypothesized to be involved in staphylococcal IE pathogenesis were tested. In parallel, the genotypic profiles of all isolates, obtained by microarray, were analyzed by discriminant analysis of principal components (DAPC)(2). No significant difference was observed between IE and bacteremia strains, regarding either phenotypic or genotypic univariate analyses. However, the multivariate statistical tool DAPC, applied on microarray data, segregated IE and bacteremia isolates: IE isolates were correctly reassigned as such in 80.6% of the cases (C-statistic 0.83, P<0.001). The performance of this model was confirmed with an independent French collection IE and bacteremia isolates (78.8% reassignment, C-statistic 0.65, P<0.01). Finally, a simple linear discriminant function based on a subset of 8 genetic markers retained valuable performance both in study collection (86.1%, P<0.001) and in the independent validation collection (81.8%, P<0.01). We here show that community-acquired IE and bacteremia S. aureus isolates are genetically distinct based on subtle combinations of genetic markers. This finding provides the proof of concept that bacterial characteristics may contribute to the occurrence of IE in patients with S. aureus bacteremia
    corecore