19 research outputs found

    Variation in Specificity of HIV Rapid Diagnostic Tests over Place and Time: An Analysis of Discordancy Data Using a Bayesian Approach

    Get PDF
    BACKGROUND Recent trends to earlier access to anti-retroviral treatment underline the importance of accurate HIV diagnosis. The WHO HIV testing strategy recommends the use of two or three rapid diagnostic tests (RDTs) combined in an algorithm and assume a population is serologically stable over time. Yet RDTs are prone to cross reactivity which can lead to false positive or discordant results. This paper uses discordancy data from Médecins Sans Frontières (MSF) programmes to test the hypothesis that the specificity of RDTs change over place and time. METHODS Data was drawn from all MSF test centres in 2007-8 using a parallel testing algorithm. A Bayesian approach was used to derive estimates of disease prevalence, and of test sensitivity and specificity using the software WinBUGS. A comparison of models with different levels of complexity was performed to assess the evidence for changes in test characteristics by location and over time. RESULTS 106, 035 individuals were included from 51 centres in 10 countries using 7 different RDTs. Discordancy patterns were found to vary by location and time. Model fit statistics confirmed this, with improved fit to the data when test specificity and sensitivity were allowed to vary by centre and over time. Two examples show evidence of variation in specificity between different testing locations within a single country. Finally, within a single test centre, variation in specificity was seen over time with one test becoming more specific and the other less specific. CONCLUSION This analysis demonstrates the variable specificity of multiple HIV RDTs over geographic location and time. This variability suggests that cross reactivity is occurring and indicates a higher than previously appreciated risk of false positive HIV results using the current WHO testing guidelines. Given the significant consequences of false HIV diagnosis, we suggest that current testing and evaluation strategies be reviewed.The authors have no funding or support to report

    Microscopy Quality Control in Médecins Sans Frontières Programs in Resource-Limited Settings

    Get PDF
    Derryck Klarkowski and Daniel Orozco describe the Médecins Sans Frontières program for monitoring the quality of microscopy for malaria, pulmonary tuberculosis, and leishmaniasis

    Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    Get PDF
    BACKGROUND: Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. METHODS: Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. RESULTS: 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. CONCLUSION: This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. TRIAL REGISTRATION: ClinicalTrials.gov, NCT01716299

    False positive HIV diagnoses in resource limited settings: operational lessons learned for HIV programmes

    Get PDF
    Access to HIV diagnosis is life-saving; however the use of rapid diagnostic tests in combination is vulnerable to wrongly diagnosing HIV infection when both screening tests give a false positive result. Misclassification of HIV patients can also occur due to poor quality control, administrative errors and lack of supervision and training of staff. Médecins Sans Frontières discovered in 2004 that HIV negative individuals were enrolled in some HIV programmes. This paper describes the result of an audit of three sites to review testing practices, implement improved testing algorithms and offer re-testing to clients enrolled in the HIV clinic

    The Evaluation of a Rapid In Situ HIV Confirmation Test in a Programme with a High Failure Rate of the WHO HIV Two-Test Diagnostic Algorithm

    Get PDF
    BACKGROUND: Concerns about false-positive HIV results led to a review of testing procedures used in a Médecins Sans Frontières (MSF) HIV programme in Bukavu, eastern Democratic Republic of Congo. In addition to the WHO HIV rapid diagnostic test algorithm (RDT) (two positive RDTs alone for HIV diagnosis) used in voluntary counselling and testing (VCT) sites we evaluated in situ a practical field-based confirmation test against western blot WB. In addition, we aimed to determine the false-positive rate of the WHO two-test algorithm compared with our adapted protocol including confirmation testing, and whether weakly reactive compared with strongly reactive rapid test results were more likely to be false positives. METHODOLOGY/PRINCIPAL FINDINGS: 2864 clients presenting to MSF VCT centres in Bukavu during January to May 2006 were tested using Determine HIV-1/2 and UniGold HIV rapid tests in parallel by nurse counsellors. Plasma samples on 229 clients confirmed as double RDT positive by laboratory retesting were further tested using both WB and the Orgenics Immunocomb Combfirm HIV confirmation test (OIC-HIV). Of these, 24 samples were negative or indeterminate by WB representing a false-positive rate of the WHO two-test algorithm of 10.5% (95%CI 6.6-15.2). 17 of the 229 samples were weakly positive on rapid testing and all were negative or indeterminate by WB. The false-positive rate fell to 3.3% (95%CI 1.3-6.7) when only strong-positive rapid test results were considered. Agreement between OIC-HIV and WB was 99.1% (95%CI 96.9-99.9%) with no false OIC-HIV positives if stringent criteria for positive OIC-HIV diagnoses were used. CONCLUSIONS: The WHO HIV two-test diagnostic algorithm produced an unacceptably high level of false-positive diagnoses in our setting, especially if results were weakly positive. The most probable causes of the false-positive results were serological cross-reactivity or non-specific immune reactivity. Our findings show that the OIC-HIV confirmation test is practical and effective in field contexts. We propose that all double-positive HIV RDT samples should undergo further testing to confirm HIV seropositivity until the accuracy of the RDT testing algorithm has been established at programme level

    Percentage of laboratories and test centers achieving ≤5% false-positive and false-negative results for AFB microscopy.

    No full text
    <p>Percentage of laboratories and test centers achieving ≤5% false-positive and false-negative results for AFB microscopy.</p

    Percentage of laboratories and test centers achieving ≥95% agreement for malaria and AFB microscopy.

    No full text
    <p>Percentage of laboratories and test centers achieving ≥95% agreement for malaria and AFB microscopy.</p

    Percentage of laboratories and test centers achieving ≤5% false-positive and false-negative results for malaria microscopy.

    No full text
    <p>Percentage of laboratories and test centers achieving ≤5% false-positive and false-negative results for malaria microscopy.</p

    Performance of malaria and AFB microscopy.

    No full text
    <p>Malaria microscopy for parasite detection, not species differentiation.</p><p>CI, confidence interval.</p
    corecore