6 research outputs found

    Managing Deviating EQA Results:A Survey to Assess the Corrective and Preventive Actions of Medical Laboratories Testing for Oncological Biomarkers

    Get PDF
    Laboratories testing predictive biomarkers in lung and colorectal cancer are advised to participate in external quality assessment (EQA) schemes. This study aimed to investigate which corrective actions were taken by laboratories if predetermined performance criteria were not met, to ultimately improve current test practices. EQA participants from the European Society of Pathology between 2014 and 2018 for lung and colorectal cancer were contacted, if they had at least one analysis error or test failure in the provided cases, to complete a survey. For 72.4% of 514 deviating EQA results, an appropriate action was performed, most often including staff training (15.2%) and protocol revisions (14.6%). Main assigned persons were the molecular biologist (40.0%) and pathologist (46.5%). A change in test method or the use of complex techniques, such as next-generation sequencing, required more training and the involvement of dedicated personnel to reduce future test failures. The majority of participants adhered to ISO 15189 and implemented suitable actions by designated staff, not limited to accredited laboratories. However, for 27.6% of cases (by 20 laboratories) no corrective action was taken, especially for pre-analytic problems and complex techniques. The surveys were feasible to request information on results follow-up and further recommendations were provided

    Evaluation of a worldwide EQA scheme for complex clonality analysis of clinical lymphoproliferative cases demonstrates a learning effect.

    Get PDF
    Clonality analysis of immunoglobulin (IG) or T-cell receptor (TR) gene rearrangements is routine practice to assist diagnosis of lymphoid malignancies. Participation in external quality assessment (EQA) aids laboratories in identifying systematic shortcomings. The aim of this study was to evaluate laboratories' improvement in IG/TR analysis and interpretation during five EQA rounds between 2014 and 2018. Each year, participants received a total of five cases for IG and five cases for TR testing. Paper-based cases were included for analysis of the final molecular conclusion that should be interpreted based on the integration of the individual PCR results. Wet cases were distributed for analysis of their routine protocol as well as evaluation of the final molecular conclusion. In total, 94.9% (506/533) of wet tests and 97.9% (829/847) of paper tests were correctly analyzed for IG, and 96.8% (507/524) wet tests and 93.2% (765/821) paper tests were correctly analyzed for TR. Analysis scores significantly improved when laboratories participated to more EQA rounds (p=0.001). Overall performance was significantly lower (p=0.008) for non-EuroClonality laboratories (95% for IG and 93% for TR) compared to EuroClonality laboratories (99% for IG and 97% for TR). The difference was not related to the EQA scheme year, anatomic origin of the sample, or final clinical diagnosis. This evaluation showed that repeated EQA participation helps to reduce performance differences between laboratories (EuroClonality versus non-EuroClonality) and between sample types (paper versus wet). The difficulties in interpreting oligoclonal cases highlighted the need for continued education by meetings and EQA schemes

    The new IVD Regulation 2017/746: a case study at a large university hospital laboratory in Belgium demonstrates the need for clarification on the degrees of freedom laboratories have to use lab-developed tests to improve patient care.

    No full text
    Objectives The new European In Vitro Diagnostic (IVD) Regulation 2017/746 (IVDR) restricts the use of lab-developed tests (LDT) after 26th May 2022. There are no data on the impact of the IVDR on laboratories in the European Union. Methods Laboratory tests performed in UZ Leuven were divided in four groups: core laboratory, immunology, special chemistry, and molecular microbiology testing. Each test was classified as Conformité Européenne (CE)-IVD, modified/off-label CE-IVD, commercial Research Use Only (RUO) or LDT. Each matrix was considered a separate test. Results We found that 97.6% of the more than 11.5 million results/year were generated with a CE-IVD method. Of the 922 different laboratory tests, however, only 41.8% were CE-IVD, 10.8% modified/off-label CE-IVD, 0.3% RUO, and 47.1% LDT. Off-label CE-IVD was mainly used to test alternative matrices not covered by the claim of the manufacturer (e.g., pleural or peritoneal fluid). LDTs were mainly used for special chemistry, flow cytometry, and molecular testing. Excluding flow cytometry, the main reasons for the use of 377 LDTs were lack of a CE-IVD method (71.9%), analytical requirements (14.3%), and the fact the LDT was in use before CE-IVD available (11.9%). Conclusions While the large majority of results (97.6%) were generated with a CE-IVD method, only 41.8% of laboratory tests were CE-IVD. There is currently no alternative on the market for 71.5% of the 537 LDTs performed in our laboratory which do not fall within the scope of the current IVD directive (IVDD). Compliance with the IVDR will require a major investment of time and effort.status: Published onlin

    Describing the Reportable Range Is Important for Reliable Treatment Decisions A Multiple Laboratory Study for Molecular Tumor Profiling Using Next-Generation Sequencing

    No full text
    Because interpretation of next-generation sequencing (NGS) data remains challenging, optimization of the NGS process is needed to obtain correct sequencing results. Therefore, extensive validation and continuous monitoring of the quality is essential. NGS performance was compared with traditional detection methods and technical quality of nine NGS technologies was assessed. First, nine formalin-fixed, paraffin-embedded patient samples were analyzed by 114 laboratories by using different detection methods. No significant differences in performance were observed between analyses with NGS and traditional techniques. Second, two DNA control samples were analyzed for a selected number of variants by 26 participants with the use of nine different NGS technologies. Quality control metrics were analyzed from raw data files and a survey about routine procedures. Results showed large differences in coverages, but observed variant allele frequencies in raw data files were in line with predefined variant allele frequencies. Many false negative results were found because of low-quality regions, which were not reported as such. It is recommended to disclose the reportable range, the fraction of targeted genomic regions for which calls of acceptable quality can be generated, to avoid any errors in therapy decisions. NGS can be a reliable technique, only if essential quality control during analysis is applied and reported.status: publishe

    External Quality Assessment Schemes for Biomarker Testing in Oncology Comparison of Performance between Formalin-Fixed, Paraffin-Embedded-Tissue and Cell-Free Tumor DNA in Plasma

    No full text
    Liquid biopsies have emerged as a useful addition to tissue biopsies in molecular pathology. Literature has shown lower laboratory performances when a new method of variant analysis is introduced. This study evaluated the differences in variant analysis between tissue and plasma samples after the introduction of liquid biopsy in molecular analysis. Data from a pilot external quality assessment scheme for the detection of molecular variants in plasma samples and from external quality assessment schemes for the detection of molecular variants in tissue samples were collected. Laboratory performance and error rates by sample were compared between matrices for variants present in both scheme types. Results showed lower overall performance [65.6% (n = 276) versus 89.2% (n = 1607)] and higher error rates [21.0% to 43.5% (n = 138) versus 8.7% to 16.7% (n = 234 to 689)] for the detection of variants in plasma compared to tissue, respectively. In the plasma samples, performance was decreased for variants with an allele frequency of 1% compared to 5% [56.5% (n = 138) versus 74.6% (n = 138)]. The implementation of liquid biopsy in the detection of circulating tumor DNA in plasma was associated with poor laboratory performance. It is important both to apply optimal detection methods and to extensively validate new methods for testing circulating tumor DNA before treatment decisions are made.status: publishe

    Incidents in Molecular Pathology: Frequency and Causes During Routine Testing.

    No full text
    CONTEXT.— Errors in laboratory medicine could compromise patient safety. Good laboratory practice includes identifying and managing nonconformities in the total test process. Varying error percentages have been described in other fields but are lacking for molecular oncology. OBJECTIVES.— To gain insight into incident causes and frequency in the total test process from 8 European institutes routinely performing biomarker tests in non-small cell lung cancer and colorectal cancer. DESIGN.— All incidents documented in 2018 were collected from all hospital services for pre-preanalytical entries before the biomarker test, as well as specific incidents for biomarker tests. RESULTS.— There were 5185 incidents collected, of which 4363 (84.1%) occurred in the pre-preanalytical phase (all hospital services), 2796 of 4363 (64.1%) related to missing or incorrect request form information. From the other 822 specific incidents, 166 (20.2%) were recorded in the preanalytical phase, 275 (33.5%) in the analytical phase, and 194 (23.6%) in the postanalytical phase, mainly due to incorrect report content. Only 47 of 822 (5.7%) incidents were recorded in the post-postanalytical phase, and 123 (15.0%) in the complete total test process. For 17 of 822 (2.1%) incidents the time point was unknown. Pre-preanalytical incidents were resolved sooner than incidents on the complete process (mean 6 versus 60 days). For 1215 of 5168 (23.5%) incidents with known causes a specific action was undertaken besides documenting them, not limited to accredited institutes. CONCLUSIONS.— There was a large variety in the number and extent of documented incidents. Correct and complete information on the request forms and final reports are highly error prone and require additional focus