15 research outputs found

    Inverse Compton Light Source: A Compact Design Proposal

    Get PDF
    In the last decade, there has been an increasing demand for a compact Inverse Compton Light Source (ICLS) which is capable of producing high-quality X-rays by colliding an electron beam and a high-quality laser. It is only in recent years when both SRF and laser technology have advanced enough that compact sources can approach the quality found at large installations such as the Advanced Photon Source at Argonne National Laboratory. Previously, X-ray sources were either high flux and brilliance at a large facility or many orders of magnitude lesser when produced by a bremsstrahlung source. A recent compact source was constructed by Lyncean Technologies using a storage ring to produce the electron beam used to scatter the incident laser beam. By instead using a linear accelerator system forthe electron beam, a significant increase in X-ray beam quality is possible, though even subsequent designs also featuring a storage ring offer improvement. Preceding the linear accelerator with an SRF reentrant gun allows for an extremely small transverse emittance, increasing the brilliance of the resulting X-ray source. In order to achieve sufficiently small emittances, optimization was done regarding both the geometry of the gun and the initial electron bunch distribution produced off the cathode. Using double-spoke SRF cavities to comprise the linear accelerator allows for an electron beam of reasonable size to be focused at the interaction point, while preserving the low emittance that was generated by the gun. An aggressive final focusing section following the electron beam\u27s exit from the accelerator produces the small spot size at the interaction point which results in an X-ray beam of high flux and brilliance. Taking all of these advancements together, a world class compact X-ray source has been designed. It is anticipated that this source would far outperform the conventional bremsstrahlung and many other compact ICLSs, while coming closer to performing at the levels found at large facilities than ever before. The design process, including the development between subsequent iterations, is presented here in detail, with the simulation results for this groundbreaking X-ray source

    Narrow-Band Emission in Thomson Sources Operating in the High-Field Regime

    Get PDF
    We present a novel and quite general analysis of the interaction of a high-field chirped laser pulse and a relativistic electron, in which exquisite control of the spectral brilliance of the up-shifted Thomson-scattered photon is shown to be possible. Normally, when Thomson scattering occurs at high field strengths, there is ponderomotive line broadening in the scattered radiation. This effect makes the bandwidth too large for some applications and reduces the spectral brilliance. We show that such broadening can be corrected and eliminated by suitable frequency modulation of the incident laser pulse. Furthermore, we suggest a practical realization of this compensation idea in terms of a chirped-beam-driven free electron laser oscillator configuration and show that significant compensation can occur, even with the imperfect matching to be expected in these conditions

    Compact SRF Linac for High Brilliance Inverse Compton Scattering Light Source

    Get PDF
    New designs for compact SRF linacs can produce micron-size electron beams. These can can be used for inverse Compton scattering light sources of exceptional flux and brilliance

    Beam Dynamics Studies for Transverse Electromagnetic Mode Type rf Deflectors

    Get PDF
    We have performed three-dimensional simulations of beam dynamics for transverse electromagnetic mode (TEM) type rf deflectors: normal and superconducting. The compact size of these cavities as compared to the conventional TM110 type structures is more attractive particularly at low frequency. Highly concentrated electromagnetic fields between the parallel bars provide strong electrical stability to the beam for any mechanical disturbance. An array of six 2-cell normal conducting cavities or a single cell superconducting structure is enough to produce the required vertical displacement at the target point. Both the normal and superconducting structures show very small emittance dilution due to the vertical kick of the beam

    Compact Accelerator Design for a Compton Light Source

    Get PDF
    A compact electron accelerator suitable for Compton source applications is in design at the Center for Accelerator Science at Old Dominion University and Jefferson Lab. The design includes a KE=1.55 MeV low-emittance, optimized superconducting electron gun; a 23.45 MeV linac with multi-spoke 4.2 K superconducting cavities; and transport that combines magnetic longitudinal bunch compressor and transverse final focus. We report on the initial designs of each element, including end to end simulations with ASTRA and elegant, and expected beam parameters

    Pharmacokinetics and Absorption of Paromomycin and Gentamicin from Topical Creams Used To Treat Cutaneous Leishmaniasis

    Get PDF
    This study evaluated the pharmacokinetics of topical creams containing 15% paromomycin (“paromomycin alone”) and 15% paromomycin plus 0.5% gentamicin (WR 279,396) in patients with cutaneous leishmaniasis. The investigational creams were applied topically to all lesions once daily for 20 days. Plasma samples were analyzed for simultaneous quantitation of paromomycin and gentamicin isomers and total gentamicin. Pharmacokinetic parameters for gentamicin could not be calculated because detectable levels were rarely evident. After one application, the paromomycin area under the concentration-time curve from 0 to 24 h (AUC0–24) was 2,180 +/- 2,621 ng · h/ml (mean +/- standard deviation [SD]) for the paromomycin-alone group and 975.6 +/- 1,078 ng · h/ml for the WR 279,396 group. After 20 days of application, the paromomycin AUC0–24 and maximum concentration of drug (Cmax) were 5 to 6 times greater than those on day 1 for both treatment groups. For the paromomycin-alone group, the AUC0–24 was 8,575 +/- 7,268 ng · h/ml and the Cmax was 1,000 +/- 750 ng/ml, compared with 6,037 +/- 3,956 ng · h/ml and 660 +/- 486 ng/ml for the WR 279,396 group, respectively. Possibly due to large intersubject variability, no differences (P\u3e0.05) in the AUC0–24 or Cmax were noted between treatment or between sites on day 1 or 20. The percentage of dose absorbed on day 20 was 12.0% +/- 6.26% and 9.68% +/- 6.05% for paromomycin alone and WR 279,396, respectively. Paromomycin concentrations in plasma after 20 days of application were 5 to 9% of those after intramuscular administration of 15 mg/kg of body weight/day to adults for the systemic treatment of visceral leishmaniasis. Effective topical treatment of cutaneous leishmaniasis appears to be possible with limited paromomycin and gentamicin systemic absorption, thus avoiding drug accumulation and toxicity. (The work described here has been registered at ClinicalTrials.gov under registration no. NCT01032382 and NCT01083576.

    Intense monochromatic photons above 100 keV from an inverse Compton source

    Get PDF
    Quasimonochromatic x rays are difficult to produce above 100 keV, but have a number of uses in x-ray and nuclear science, particularly in the analysis of transuranic species. Inverse Compton scattering (ICS) is capable of fulfilling this need, producing photon beams with properties and energies well beyond the limits of typical synchrotron radiation facilities. We present the design and predicted output of such an ICS source at CBETA, a multiturn energy-recovery linac with a top energy of 150 MeV, which we anticipate producing x rays with energies above 400 keV and a collimated flux greater than 108 photons per second within a 0.5% bandwidth. At this energy, the anticipated flux exceeds that attainable from storage ring sources of synchrotron radiation, even though CBETA is a significantly smaller accelerator system. We also consider the consequences of extending the CBETA ICS source performance to higher electron energies, exploring achievable parameters and applications for MeV-scale photons. We foresee that future energy-recovery linacs may serve as ICS sources, capable of providing high energy photons unavailable at synchrotron radiation facilities or photon beams above approximately 300 keV which outperform sources at synchrotron radiation facilities in both flux and average brilliance

    Beam dynamics studies for transverse electromagnetic mode type rf deflectors

    Get PDF
    We have performed three-dimensional simulations of beam dynamics for transverse electromagnetic mode (TEM) type rf deflectors: normal and superconducting. The compact size of these cavities as compared to the conventional TM_{110} type structures is more attractive particularly at low frequency. Highly concentrated electromagnetic fields between the parallel bars provide strong electrical stability to the beam for any mechanical disturbance. An array of six 2-cell normal conducting cavities or a single cell superconducting structure is enough to produce the required vertical displacement at the target point. Both the normal and superconducting structures show very small emittance dilution due to the vertical kick of the beam
    corecore