154 research outputs found

    NASA DC-8 airborne research laboratory

    Get PDF
    Since the summer of 1987, NASA Ames Research Center has been operating a DC-8 equipped with CFM 56 engines as a flying research laboratory. In this relatively short time, the DC-8, with its tremendous capabilities, has made significant contributions to numerous scientific fields. Capable of staying aloft for over 12 hours, the DC-8 has flown directly over both the North and South Poles, gathering data relating to the ozone hole. Operating from a few thousand feet to over 40,000 feet above sea level the interchangeable payload capability of the DC-8 has made it a versatile scientific tool. The DC-8 also plays a vital role in the development of new satellite-borne sensors as very often those sensors are test-flown on the DC-8 before they are launched into space. The tremendous range and instrument carrying capability make the DC-8 an ideal flying laboratory. A few of the programs the DC-8 has participated in as well as a sampling of the instruments carried are outlined

    A twenty-year survey of dermatophytoses in Braga, Portugal

    Get PDF
    Modifications in social habits together with the increase of emigration have contributed not only to increased dermatophytoses but also to an altered etiology. During the last few years, Braga has suffered a radical change from a rural to a cosmopolitan life-style

    What are we measuring? A critique of range of motion methods currently in use for Dupuytren's disease and recommendations for practice

    Get PDF
    Background: Range of motion is the most frequently reported measure used in practice to evaluate outcomes. A goniometer is the most reliable tool to assess range of motion yet, the lack of consistency in reporting prevents comparison between studies. The aim of this study is to identify how range of motion is currently assessed and reported in Dupuytren’s disease literature. Following analysis recommendations for practice will be made to enable consistency in future studies for comparability. This paper highlights the variation in range of motion reporting in Dupuytren’s disease. Methods: A Participants, Intervention, Comparison, Outcomes and Study design format was used for the search strategy and search terms. Surgery, needle fasciotomy or collagenase injection for primary or recurrent Dupuytren’s disease in adults were included if outcomes were monitored using range of motion to record change. A literature search was performed in May 2013 using subject heading and free-text terms to also capture electronic publications ahead of print. In total 638 publications were identified and following screening 90 articles met the inclusion criteria. Data was extracted and entered onto a spreadsheet for analysis. A thematic analysis was carried out to establish any duplication, resulting in the final range of motion measures identified. Results: Range of motion measurement lacked clarity, with goniometry reportedly used in only 43 of the 90 studies, 16 stated the use of a range of motion protocol. A total of 24 different descriptors were identified describing range of motion in the 90 studies. While some studies reported active range of motion, others reported passive or were unclear. Eight of the 24 categories were identified through thematic analysis as possibly describing the same measure, ‘lack of joint extension’ and accounted for the most frequently used. Conclusions: Published studies lacked clarity in reporting range of motion, preventing data comparison and meta-analysis. Percentage change lacks context and without access to raw data, does not allow direct comparison of baseline characteristics. A clear description of what is being measured within each study was required. It is recommended that range of motion measuring and reporting for Dupuytren’s disease requires consistency to address issues that fall into 3 main categories:- Definition of terms Protocol statement Outcome reportin

    Optimal functional outcome measures for assessing treatment for Dupuytren's disease: A systematic review and recommendations for future practice

    Get PDF
    This article is available through the Brunel Open Access Publishing Fund. Copyright © 2013 Ball et al.; licensee BioMed Central Ltd.Background: Dupuytren's disease of the hand is a common condition affecting the palmar fascia, resulting in progressive flexion deformities of the digits and hence limitation of hand function. The optimal treatment remains unclear as outcomes studies have used a variety of measures for assessment. Methods: A literature search was performed for all publications describing surgical treatment, percutaneous needle aponeurotomy or collagenase injection for primary or recurrent Dupuytren’s disease where outcomes had been monitored using functional measures. Results: Ninety-one studies met the inclusion criteria. Twenty-two studies reported outcomes using patient reported outcome measures (PROMs) ranging from validated questionnaires to self-reported measures for return to work and self-rated disability. The Disability of Arm, Shoulder and Hand (DASH) score was the most utilised patient-reported function measure (n=11). Patient satisfaction was reported by eighteen studies but no single method was used consistently. Range of movement was the most frequent physical measure and was reported in all 91 studies. However, the methods of measurement and reporting varied, with seventeen different techniques being used. Other physical measures included grip and pinch strength and sensibility, again with variations in measurement protocols. The mean follow-up time ranged from 2 weeks to 17 years. Conclusions: There is little consistency in the reporting of outcomes for interventions in patients with Dupuytren’s disease, making it impossible to compare the efficacy of different treatment modalities. Although there are limitations to the existing generic patient reported outcomes measures, a combination of these together with a disease-specific questionnaire, and physical measures of active and passive individual joint Range of movement (ROM), grip and sensibility using standardised protocols should be used for future outcomes studies. As Dupuytren’s disease tends to recur following treatment as well as extend to involve other areas of the hand, follow-up times should be standardised and designed to capture both short and long term outcomes

    Further evidence of the involvement of the Wnt signaling pathway in Dupuytren’s disease

    Get PDF
    Genetic background plays an important role in the development of Dupuytren's disease. A genome-wide association study (GWAS) showed that nine loci are associated with the disease, six of which contain genes that are involved in Wnt signaling (WNT2, WNT4, WNT7B, RSPO2, SFRP4, SULF1). To obtain insight in the role of these genes, we performed expression studies on affected and unaffected patient's tissues. Surgically obtained nodules and cords from eight Dupuytren's patients were compared to patient-matched control tissue (unaffected transverse palmar fascia). The Wnt-related genes found in the GWAS, the classical Wnt-downstream protein beta-catenin, as well as (myo) fibroblast markers were analyzed using real-time qPCR and immunohistochemical stainings for mRNA levels and protein levels, respectively. The collagen-coding genes COL1A1 and COL3A1 were highly upregulated on mRNA level, both in cords and nodules. Three Wnt-related genes were found to be differently regulated compared to control tissue: WNT2 was downregulated in nodules, WNT7B was upregulated in nodules, and SFRP4 was upregulated in nodules and cords. Immunohistochemistry revealed significantly less staining of Wnt2 in cords, but significantly more staining for Wnt7b in nodules. There was significantly more staining of alpha-SMA in nodules and cord and beta-catenin in nodules than in control tissue. We found differences in expression, both at mRNA and protein level, in several Wnt-related genes found earlier to be associated with Dupuytren's disease. Of these, Wnt7b was upregulated and found in close association with both alpha-SMA and beta-catenin expressing cells, making it a candidate pro-fibrotic mediator in Dupuytren's disease

    Treating postoperative wounds with an amorphous hydrogel

    No full text
    • …
    corecore