4 research outputs found

    Tensile and fatigue data for irradiated and unirradiated AISI 310 stainless steel and titanium - 5 percent aluminum - 2.5 percent tin: Application of the method of universal slopes

    Get PDF
    Irradiated and unirradiated tensile and fatigue specimens of AISI 310 stainless steel and Ti-5Al-2.5Sn were tested in the range of 100 to 10,000 cycles to failure to determine the applicability of the method of universal slopes to irradiated materials. Tensile data for both materials showed a decrease in ductility and increase in ultimate tensile strength due to irradiation. Irradiation caused a maximum change in fatigue life of only 15 to 20 percent for both materials. The method of universal slopes predicted all the fatigue data for the 310 SS (irradiated as well as unirradiated) within a life factor of 2. For the titanium alloy, 95 percent of the data was predicted within a life factor of 3

    Some comparisons of the flow characteristics of a turbofan compressor system with and without inlet pressure distortion

    Get PDF
    The measured effects of a circumferential distortion in inlet total pressure on the fan, low, and high compressor of an afterburning turbofan engine are presented and discussed. Extensive inner-stage instrumentation, combined with a unique test technique offered an accurate means of measuring the shifts in flow, performance, and stall mechanisms within the compressor. These effects are compared at one speed to the corresponding effects measured with undistorted inlet flow. The results show the rate at which the distorted flow areas were attenuated and rotated as well as the change in flow velocities that occurred at various points in the compressor. High response pressure traces indicated the location of stalls including the sequence of dynamic events from the onset and propagation of various stall-recovery events, to compressor surge, to the resulting hammershock

    Effect of a 180 deg-extent inlet pressure distortion on the internal flow conditions of a TF30-P-3

    Get PDF
    The measured effects of inlet pressure distortion on the internal flow temperatures and pressures of a TF30-P-3 afterburning turbofan engine are reported. Extensive inner-stage instrumentation combined with stepwise rotation of pressure distortion provided a high degree of circumferential resolution in the data. The steady-state spatial variation in pressures, temperature, and calculated flow velocity and the amplitude and extent of the distorted sectors are given. Data are presented for runs of 77 and 90 percent of low-speed-rotor design speed at pressure distortion levels two-thirds of that required to stall the engine. These data are compared with data taken at clean-inlet conditions. Results indicate that the inlet pressure distortion was quickly attenuated within the compressor, except at the hub of the low-pressure compressor. The distorted sectors also swirled and varied in extent as they passed through the engine. Average velocities within the compressor were about equal to the clean-inlet values

    Internal flow characteristics of a multistage compressor with inlet pressure distortion

    Get PDF
    The measured distribution of compressor interstage pressures and temperatures resulting from a 180 deg inlet-total-pressure distortion for a J85-13 turbojet engine is reported. Extensive inner stage instrumentation combined with stepwise rotation of the inlet distortion gave data of high circumferential resolution. The steady-state pressures and temperatures along with the amplitude, extent, and location of the distorted areas are given. Data for 80, 90, and 100 percent of rotor design speed are compared with clean (undistorted) inlet flow conditions to show pressure and temperature behavior within the compressor. Both overall and stagewise compressor performances vary only slightly when clean and distorted inlet conditions are compared. Total and static pressure distortions increase in amplitude in the first few stages of the compressor and then attenuate fairly uniformly to zero at the discharge. Total-temperature distortion induced by the pressure distortion reached a maximum amplitude by the first two stages and decayed only a little through the rest of the compressor. Distortion amplitude tended to peak in line with the screen edges, and, except for total and static pressure in the tip zone, there was little swirl in the axial direction
    corecore