32 research outputs found

    Pressure transduction and fluid evacuation during conventional negative pressure wound therapy of the open abdomen and NPWT using a protective disc over the intestines

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Negative pressure wound therapy (NPWT) has gained acceptance among surgeons, for the treatment of open abdomen, since very high closure rates have been reported with this method, compared to other kinds of wound management for the open abdomen. However, the method has occasionally been associated with increased development of fistulae. We have previously shown that NPWT induces ischemia in the underlying small intestines close to the vacuum source, and that a protective disc placed between the intestines and the vacuum source prevents the induction of ischemia. In this study we compare pressure transduction and fluid evacuation of the open abdomen with conventional NPWT and NPWT with a protective disc.</p> <p>Methods</p> <p>Six pigs underwent midline incision and the application of conventional NPWT and NPWT with a protective disc between the intestines and the vacuum source. The pressure transduction was measured centrally beneath the dressing, and at the anterior abdominal wall, before and after the application of topical negative pressures of -50, -70 and -120 mmHg. The drainage of fluid from the abdomen was measured, with and without the protective disc.</p> <p>Results</p> <p>Abdominal drainage was significantly better (p < 0. 001) using NPWT with the protective disc at -120 mmHg (439 ± 25 ml vs. 239 ± 31 ml), at -70 mmHg (341 ± 27 ml vs. 166 ± 9 ml) and at -50 mmHg (350 ± 50 ml vs. 151 ± 21 ml) than with conventional NPWT. The pressure transduction was more even at all pressure levels using NPWT with the protective disc than with conventional NPWT.</p> <p>Conclusions</p> <p>The drainage of the open abdomen was significantly more effective when using NWPT with the protective disc than with conventional NWPT. This is believed to be due to the more even and effective pressure transduction in the open abdomen using a protective disc in combination with NPWT.</p

    Microvascular blood flow response in the intestinal wall and the omentum during negative wound pressure therapy of the open abdomen

    Get PDF
    PURPOSE: Higher closure rates of the open abdomen have been reported with negative pressure wound therapy (NPWT) compared with other wound therapy techniques. However, the method has occasionally been associated with increased development of intestinal fistulae. The present study measures microvascular blood flow in the intestinal wall and the omentum before and during NPWT. METHODS: Six pigs underwent midline incision and application of NPWT to the open abdomen. The microvascular blood flow in the underlying intestinal loop wall and the omentum was recorded before and after the application of NPWT of -50, -70, -100, -120, -150, and -170 mmHg respectively, using laser Doppler velocimetry. RESULTS: A significant decrease in microvascular blood flow was seen in the intestinal wall during application of all negative pressures levels. The blood flow was 2.7 (±0.2) Perfusion Units (PU) before and 2.0 (±0.2) PU (*p < 0.05) after application of -50 mmHg, and 3.6 (±0.6) PU before and 1.5 (±0.2) PU (**p < 0.01) after application of -170 mmHg. CONCLUSIONS: In the present study, we show that negative pressures between -50 and -170 mmHg induce a significant decrease in the microvascular blood flow in the intestinal wall. The decrease in blood flow increased with the amount of negative pressure applied. One can only speculate that a longstanding decreased blood flow in the intestinal wall may induce ischemia and secondary necrosis in the intestinal wall, which, theoretically, could promote the development of intestinal fistulae. We believe that NPWT of the open abdomen is a very effective treatment but could probably be improved

    Temporary Closure of the Open Abdomen: A Systematic Review on Delayed Primary Fascial Closure in Patients with an Open Abdomen

    Get PDF
    Background This study was designed to systematically review the literature to assess which temporary abdominal closure (TAC) technique is associated with the highest delayed primary fascial closure (FC) rate. In some cases of abdominal trauma or infection, edema or packing precludes fascial closure after laparotomy. This "open abdomen'' must then be temporarily closed. However, the FC rate varies between techniques. Methods The Cochrane Register of Controlled Trials, MEDLINE, and EMBASE databases were searched until December 2007. References were checked for additional studies. Search criteria included (synonyms of) "open abdomen,'' "fascial closure,'' "vacuum,'' "reapproximation,'' and "ventral hernia.'' Open abdomen was defined as "the inability to close the abdominal fascia after laparotomy.'' Two reviewers independently extracted data from original articles by using a predefined checklist. Results The search identified 154 abstracts of which 96 were considered relevant. No comparative studies were identified. After reading them, 51 articles, including 57 case series were included. The techniques described were vacuum-assisted closure (VAC; 8 series), vacuum pack (15 series), artificial burr (4 series), Mesh/sheet (16 series), zipper (7 series), silo (3 series), skin closure (2 series), dynamic retention sutures (DRS), and loose packing (1 series each). The highest FC rates were seen in the artificial burr (90%), DRS (85%), and VAC (60%). The lowest mortality rates were seen in the artificial burr (17%), VAC (18%), and DRS (23%). Conclusions These results suggest that the artificial burr and the VAC are associated with the highest FC rates and the lowest mortality rate
    corecore