954 research outputs found

    Monitoring early-age acoustic emission of cement paste and fly ash paste

    Get PDF
    In this study, a combined approach of several monitoring techniques was applied to allow correlations between the AE activity and related processes such as shrinkage and settlement evolution, capillary pressure and temperature development in fresh cementitious media. AE parameters related to frequency, energy, and cumulative activity which exhibit sensitivity to the particle size distribution of cement paste are compared with inert fly ash (FA) leading to isolation of the mechanical sources from the chemical ones. Characterization of the origin of different processes occurring in cement paste during hydration is complex. Although acoustic emission (AE) monitoring has been used before, a qualitative relation between the microstructural formation or other early-age processes and the number or parameters of AE signals has not been established. The high sensitivity of AE enables the recording of elastic waves within the cementitious material, allowing the detection of even low-intensity activities

    Monitoring of fresh concrete curing by combined NDT techniques

    Get PDF
    Ensuring the quality of fresh concrete and suitable curing conditions substantially reduces the possibility of future failure to perform as designed. However, the most reliable examination for concrete is mechanical testing after hardening. In order to obtain better control on the process from very early age, this study describes a combined approach of several monitoring techniques. Acoustic emission is used to record the numerous events occurring during the first hours when concrete is in liquid form as well as later when hardening takes place and drying shrinkage cracking is exhibited. In addition, pressure sensors follow the development of capillary pressure in the matrix and indicate the moment of air entry into the system. Settlement and shrinkage, measured both non-contact by digital image correlation and conventionally, as well as temperature shed light into the complex processes occurring into fresh concrete and help to verify the sources of AE. The final aim is to develop a methodology to assess the quality of the fresh concrete from an early age, to possibly project to the final mechanical properties and to ensure a proper service life

    Structural build-up of cementitious paste under external magnetic fields

    No full text
    Engineering application processes of fresh concrete include transporting, pumping, formwork casting, etc. Each process is a significant factor influencing properties of fresh and hardened concrete. However, many contradicting requirements of fresh concrete performances (such as structuration rate) exist in these operation processes. Therefore, advanced techniques need to be proposed to satisfy future challenges. Actively controlling the stiffness by applying external magnetic fields would be a potential solution for the contradicting requirements, and could make the pumping and casting processes smarter and more reliable. In the present paper, the effects of magnetic field strength and magnetizing time on structural build-up of cementitious paste are discussed. The results show that higher magnetic field strengths result in higher percolation time and lower phase angle at equilibrium state. However, the application of external magnetic fields with low flux density has little effects on the viscoelastic behaviour of cementitious paste. Under high magnetic field strengths, the viscousliquid behaviour dominates the elastic-solid behaviour at early stage, while the solid-like behaviour becomes more dominant with magnetizing time

    Experimental study of formwork tightness as a function of rheological properties of SCC

    No full text
    Several studies relating formwork pressure to rheology exist, however the relationship between rheology and leakage through formwork joints remains to be investigated. In practice, standard documents are used to define formwork tightness requirements, typically using a qualitative approach. To try bridge this gap in knowledge, we developed a test set-up to study tightness of formwork joints under pressure as a function of varying rheological properties. Coupled with standard rheology tests, this new test set-up provides means of linking flow rate, formwork pressure, flow area, and the rheological properties. The study seeks to provide insight on measurable governing parameters and thus inform formwork tightness requirements in a more quantifiable manner. This paper presents a test set-up designed to study the flow of fresh paste through small openings. It highlights a preliminary study on the pressure-driven flow of limestone paste through a bottom orifice in a cylindrical container. While this new device may not be directly representative of the actual conditions in formwork, it provides a good base for a fundamental study that can then be extrapolated to a more representative test operation. Preliminary results show a linear relationship between the flow rate and the applied pressure. The results also show that increasing the flow area by a factor of 2.33 had a higher impact than an increase in yield stress and viscosity by a factor of 2.54 and 3.80 respectively. However, more tests need to be carried out to obtain clear trends

    Diagnosing overtraining in athletes using the two-bout exercise protocol

    Get PDF
    Objective: In this work, whether a two-bout exercise protocol can be used to make an objective, immediately available distinction between non-functional over reaching (NFO) and overtraining syndrome (OTS) was studied. Design: Underperforming athletes who were diagnosed with the suspicion of NFO or OTS were included in the study. Recovery of the athletes was monitored by a sports physician to retrospectively distinguish NFO from OTS. Setting: Sports medicine laboratory Participants: The protocol was started and completed by 10 underperforming athletes. NFO was retrospectively diagnosed in five athletes, and OTS was diagnosed in five athletes. Interventions: A two-bout maximal exercise protocol was used to measure physical performance and stressinduced hormonal reactions. Main outcome measurements: Exercise duration, heart rate and blood lactate concentration were measured at the end of both exercise tests. Venous concentrations cortisol, adrenocorticotrophic hormone (ACTH), prolactin and growth hormone were measured both before and after both exercise tests. Results: Maximal blood lactate concentration was lower in OTS compared with NFO, while resting concentrations of cortisol, ACTH and prolactin concentrations were higher. However, sensitivity of these measures was low. The ACTH and prolactin reactions to the second exercise bout were much higher in NFO athletes compared with OTS and showed the highest sensitivity for making the distinction. Conclusions: NFO might be distinguished from OTS based on ACTH and prolactin reactions to a two-bout exercise protocol. This protocol could be a useful tool for diagnosing NFO and OTS; however, more data should be collected before this test can be used as the gold standard

    Irregular screening participation increases advanced stage breast cancer at diagnosis:A population-based study

    Get PDF
    Objective: To evaluate the effect of irregular screening behaviour on the risk of advanced stage breast cancer at diagnosis in Flanders. Methods: All women aged 50–69 who were invited to the organized breast cancer screening and diagnosed with breast cancer before age 72 from 2001 to 2018 were included. All prevalent screen and interval cancers within 2 years of a prevalent screen were excluded. Screening behaviour was categorized based on the number of invitations and performed screenings. Four groups were defined: regular, irregular, only-once, and never attenders. Advanced stage cancer was defined as a stage III + breast cancer. The association between screening regularity and breast cancer stage at diagnosis was evaluated in multivariable logistic regression models, taking age of diagnosis and socio-economic status into account. Results: In total 13.5% of the 38,005 breast cancer cases were diagnosed at the advanced stage. Compared to the regular attenders, the risk of advanced stage breast cancer for the irregular attenders, women who participated only-once, and never attenders was significantly higher with ORadjusted:1.17 (95%CI:1.06–1.29) and ORadjusted:2.18 (95%CI:1.94–2.45), and ORadjusted:5.95 (95%CI:5.33–6.65), respectively. Conclusions: In our study, never attenders were nearly six times more likely to be diagnosed with advanced stage breast cancer than regular attenders, which was much higher than the estimates published thus far. An explanation for this is that the ever screened women is a heterogeneous group regarding the participation profiles which also includes irregular and only-once attenders. The benefit of regular screening should be informed to all women invited for screening

    Similarities and differences of pumping conventional and self-compacting concrete

    Get PDF
    In Practice, Self-Compacting Concrete (SCC) is Considered as a Simple Extension of Conventional Vibrated Concrete (CVC) When Pumping is Concerned. the Same Equipment, Materials, Pumping Procedures and Guidelines Used for CVC Are Applied When Pumping SCC. on the Other Hand, It Has Been Clearly Shown that the Rheological Properties and the Mix Design of SCC Are Different Than CVC. Can the Same Pumping Principles Employed for CVC Be Applied for SCC? This Paper Compares the Some Published Results of Pumping of CVC with Those for SCC. a First Striking Difference between Pumping of CVC and SCC is the Flow Behaviour in the Pipes. the Flow of CVC is a Plug, Surrounded by a Lubricating Layer, While during the Flow of SCC, Part of the Concrete Volume itself is Sheared Inside the Pipe. as a Result, the Importance of Viscosity Increases in Case of SCC. Due to the Low Yield Stress of SCC, the Behaviour in Bends is Different, But Quite Complex to Study. Due to the Lower Content of Aggregate and Better Stability of SCC, as It is Less Prone to Internal Water Migration, Blocking is Estimated to Occur at Lower Frequency in Case of SCC. © RILEM 2010
    corecore