3,893 research outputs found

    Soluções hipertônicas para reanimação de pacientes em choque

    Get PDF
    Small volume hypertonic resuscitation is a relatively new conceptual approach to shock therapy. It was originally based on the idea that a relatively large blood volume expansion could be obtained by administering a relatively small volume of fluid, taking advantage of osmosis. It was soon realized that the physiological vasodilator property of hypertonicity was a useful byproduct of small volume resuscitation in that it induced reperfusion of previously ischemic territories, even though such an effect encroached upon the malefic effects of the ischemia-reperfusion process. Subsequent research disclosed a number of previously unsuspected properties of hypertonic resuscitation, amongst them the correction of endothelial and red cell edema with significant consequences in terms of capillary blood flow. A whole set of actions of hypertonicity upon the immune system are being gradually uncovered, but the full implication of these observations with regard to the clinical scenario are still under study. Small volume resuscitation for shock is in current clinical use in some parts of the world, in spite of objections raised concerning its safety under conditions of uncontrolled bleeding. These objections stem mainly from experimental studies, but there are few signs that they may be of real clinical significance. This review attempts to cover the earlier and the more recent developments in this field.O uso de soluções hipertônicas para reanimação de pacientes em choque é um conceito relativamente novo. Baseou-se originalmente na idéia de que uma expansão volêmica significativa podia ser obtida às custas de um volume relativamente diminuto de infusão, aproveitando a propriedade física de osmose. Logo ficou claro que a capacidade fisiológica de produzir vasodilatação, compartilhada por todas as soluções hipertônicas, seria valiosa para reperfundir territórios tornados isquêmicos pelo choque, embora os malefícios da seqüência isquemia - reperfusão devessem ser considerados. Pesquisa subseqüente revelou propriedades antes insuspeitadas da reanimação hipertônica. Verificou-se que este procedimento revertia instantaneamente o edema endotelial e de hemácias, com importantes conseqüências em termos de circulação capilar. Mais recentemente, um conjunto de efeitos da hipertonicidade sobre o sistema imune vem sendo estudado, mas as possíveis implicações destas descobertas em relação ao cenário clínico ainda suscitam discussão. As soluções hipertônicas estão em uso em algumas partes do mundo, apesar de objeções levantadas contra tal uso, em virtude de dados experimentais derivados de experimentos de hemorragia não controlada. Tais objeções não parecem se justificar em face dos resultados obtidos numa série de ensaios clínicos e no uso corrente destas soluções. Esta revisão procura cobrir um pouco da história, remota e recente, deste campo do conhecimento

    Photoluminescence Intensity Enhancement in Tin Halide Perovskites

    Get PDF
    The prevalence of background hole doping in tin halide perovskites usually dominates their recombination dynamics. The addition of excess Sn halide source to the precursor solution is the most frequently used approach to reduce the hole doping and reveals photo-carrier dynamics related to defects activity. This study presents an experimental and theoretical investigation on defects under light irradiation in tin halide perovskites by combining measurements of photoluminescence with first principles computational modeling. It finds that tin perovskite thin films prepared with an excess of Sn halide sources exhibit an enhancement of the photoluminescence intensity over time under continuous excitation in inert atmosphere. The authors propose a model in which light irradiation promotes the annihilation of VSn2−/Sni2+ Frenkel pairs, reducing the deep carrier trapping centers associated with such defect and increasing the radiative recombination. Importantly, these observations can be traced in the open-circuit voltage dynamics of tin-based halide perovskite solar cells, implying the relevance of controlling the Sn photochemistry to stabilize tin perovskite devices

    A high stability semiconductor laser system for a 88^{88}Sr-based optical lattice clock

    Get PDF
    We describe a frequency stabilized diode laser at 698 nm used for high resolution spectroscopy of the 1S0-3P0 strontium clock transition. For the laser stabilization we use state-of-the-art symmetrically suspended optical cavities optimized for very low thermal noise at room temperature. Two-stage frequency stabilization to high finesse optical cavities results in measured laser frequency noise about a factor of three above the cavity thermal noise between 2 Hz and 11 Hz. With this system, we demonstrate high resolution remote spectroscopy on the 88Sr clock transition by transferring the laser output over a phase-noise-compensated 200 m-long fiber link between two separated laboratories. Our dedicated fiber link ensures a transfer of the optical carrier with frequency stability of 7 \cdot 10^{-18} after 100 s integration time, which could enable the observation of the strontium clock transition with an atomic Q of 10^{14}. Furthermore, with an eye towards the development of transportable optical clocks, we investigate how the complete laser system (laser+optics+cavity) can be influenced by environmental disturbances in terms of both short- and long-term frequency stability.Comment: 9 pages, 9 figures, submitted to Appl. Phys.

    Medida da proteína S-100B sérica para classificação de risco no trauma craniano leve: estudo piloto no Brasil

    Get PDF
    BACKGROUND: Release of the neuronal protein S-100B into the circulation has been suggested as a specific indication of neuronal damage. The hypothesis that S-100B is a useful and cost-effective screening tool for the management of minor head injuries was tested. METHODS: Fifty consecutive patients sustaining isolated minor head injury were prospectively evaluated in the emergency room of a Brazilian hospital by routine cranial computed tomography scan. Venous blood samples (processed to serum) were assssayed for S-100B using a newly developed immunoassay test kit. Twenty-one normal healthy individuals served as negative controls. Data are presented as median and 25 to 75 percentiles. RESULTS: Patients reached the emergency room an average of 45 minutes (range: 30-62 minutes) after minor head injury. Six of 50 patients (12%) showed relevant posttraumatic lesions in the initial cranial computed tomography scan and were counted as positive. The median systemic concentration of S-100B in those patients was 0.75 µg/L (range: 0.66-6.5 µg/L), which was significantly different (U-test, P < .05) from the median concentration of 0.26 µg/L (range: 0.12-0.65 µg/L), of patients without posttraumatic lesions as counted by the cranial computed tomography. A sensitivity of 100%, a specificity of 20%, a positive predictive value of 15%, and a negative predictive value of 100% was calculated for the detection of patients suffering from intracranial lesions. CONCLUSIONS: Protein S-100B had a very high sensitivity and negative predictive value and could have an important role in ruling out the need for cranial computed tomography scan after minor head injury. This appears to be of substantial clinical relevance, particularly in countries where trauma incidence is high and medical resources are limited, such as in Brazil.INTRODUÇÃO: A liberação da proteína neuronal S-100B na circulação tem sido sugerida como indicadora de dano neuronal. Foi testada a hipótese de que a S-100B é um marcador útil e custo efetivo para a triagem de pacientes com trauma craniano leve. MÉTODO: Cinqüenta pacientes consecutivos com trauma craniano isolado foram prospectivamente avaliados na sala de emergência de um Centro de Trauma brasileiro pela tomografia computadorizada de crânio e por amostras de sangue venoso, para a medida no soro da proteína S-100B utilizando um teste recentemente desenvolvido; 21 pessoas normais foram utilizadas como controles negativos. Os resultados são apresentados como mediana e percentis 25-75. RESULTADOS: Os pacientes chegaram ao Centro de Trauma em média 45 min (30-62) após o trauma craniano leve. Seis dos 50 pacientes tiveram lesões pós-traumáticas relevantes segundo a tomografia computadorizada de crânio inicial (12%) e foram considerados como positivos. A concentração mediana de S-100B nestes pacientes foi de 0,75µg/L (0,66-6,5), significativamente maior (U-teste,

    Pulse Oximetry Wave Variation as a Noninvasive Tool to Assess Volume Status in Cardiac Surgery

    Get PDF
    OBJECTIVE: To compare variations of plethysmographic wave amplitude (&#916;Ppleth) and to determine the percent difference between inspiratory and expiratory pulse pressure (&#916;Pp) cutoff values for volume responsiveness in a homogenous population of postoperative cardiac surgery patients. INTRODUCTION: Intra-thoracic pressure variations interfere with stroke volume variation. Pulse pressure variations through arterial lines during mechanical ventilation have been recommended for the estimation of fluid responsiveness. Pulse oximetry may offer a non-invasive plethysmographic method to evaluate pulse pressure; this may be useful for guiding fluid replacement. METHODS: Controlled, prospective study in cardiac surgery patients under controlled ventilation. Simultaneous digital recordings of arterial pressure and plethysmographic waves were performed. &#916;Pp, systolic pressure (&#916;Ps), DPpleth, and systolic component (&#916;Spleth) were calculated. A DPp > 13% identified fluid-responsive patients. Volume expansion was performed in responsive subjects. Systolic and amplitude components of pressure and plethysmographic waves were compared. RESULTS: In 50 measurements from 43 patients, &#916;Pp was correlated with (Ppleth (r=0.90, p<0.001), (Ps (r=0.90, p<0.001), and (Spleth (r=0.73, p<0.001). An aArea under ROC curve (AUC) identified the fluid responsiveness thresholds: (Ppleth of 11% (AUC = 0.95±0.04), (Ps of 8% (AUC=0.93±0.05), and (Spleth of 32% (AUC=0.82±0.07). A (Ppleth value > 11% predicted (Pp > 13% with 100% specificity and 91% sensitivity. Volume expansion, performed in 20 patients, changed (Pp, (Ppleth, (Ps and (Spleth significantly (p<0.008). CONCLUSIONS: &#916;Ppleth is well correlated with DPp and constitutes a simple and non-invasive method for assessing fluid responsiveness in patients following cardiac surgery

    Avaliação in vivo da interação leucócito-endotélio mesentérico após ligadura e punção cecal e remoção cirúrgica do foco sééptico

    Get PDF
    PURPOSE: Cecal ligation and puncture (CLP) has been used as a useful model for the induction of polymicrobial sepsis. Necrotic tissue resection and peritoneal lavage (REL) are the surgical procedures for controlling perforated appendicitis. The aim of this study was to evaluate leukocyte-endothelial interactions in the rat mesentery in vivo after CLP and REL. METHODS: Thirty-seven male Wistar rats (250-300 g) underwent laparotomy and were randomly assigned to the following groups: 1) SHAM; 2) CLP: animals submitted to CLP, 3) CLP+REL: animals submitted to CLP and REL. Mesenteric leukocyte-endothelial interactions were studied by intravital microscopy assessed once in each animal (3-5 postcapillary venules, 15-25 µm diameter) 24 hours after intervention. Follow-up was performed in all animals; this included analysis of glycemia, lactate, hematocrit, white blood cell count as well as a functional score that was the sum of scoring on the following parameters: alertness, mobility, piloerection, diarrhea, encrusted eyes, and dirty nose and tail. RESULTS: None of the animals showed significant changes in body weight (265 ± 20 g) or in hematocrit levels (46% ± 2%) during the experimental protocol. Compared to SHAM animals, CLP animals showed an increased number of rolling (2x), adherent, and migrating leukocytes (7x) in the mesenteric microcirculation, an increase in blood glucose (136 ± 8 mg/dL), lactate (3.58 ± 0.94 mmol/L), white cell count (23,570 ± 4,991 cells/mm³) and functional alterations (score 11 ± 1), characterized by impaired alertness and mobility, and presence of piloerection, diarrhea, encrusted eyes, and dirty nose and tail. The REL procedure normalized the number of rolling, adherent, and migrated leukocytes in the mesentery; glycemia; lactate; and white blood cell count. The REL procedure also improved the functional score (7 ± 1). CONCLUSION: Local and systemic inflammation was induced by CLP, while REL completely overcame the inflammatory process.OBJETIVO: O procedimento de ligadura cecal e perfuração (CLP) tem sido usado como um modelo útil de indução de sepse polimicrobiana. A ressecção do tecido necrosado e lavagem peritoneal (REL) são procedimentos cirúrgicos freqüentemente utilizados para controlar uma apendicite perfurada. O objetivo desse estudo foi avaliar in vivo as interações leucócito-endotélio no mesentério de ratos após a CLP e REL. MÉTODOS: Trinta e sete ratos Wistar machos (250-300 g) foram submetidos à laparotomia e aleatoriamente divididos em grupos: 1) SHAM, 2) CLP: ratos submetidos à CLP, 3) CLP+REL: animais submetidos à CLP e REL. As interações leucócito-endotélio no mesentério foram estudadas através de microscopia intravital somente uma vez em cada animal (3-5 vênulas pós-capilares, 15-25 µm diâmetro), 24-horas após as intervenções. A evolução clínica foi realizada em todos os animais, incluindo glicemia, lactato, hematócrito, número total de células brancas e um escore funcional, o qual foi considerado como a somatória dos seguintes parâmetros: estado de alerta, mobilidade, piloereção, diarréia, olhos encrustados, e nariz e cauda sujos. RESULTADOS: Os animais não apresentaram alterações significantes no peso (265 ± 20 g) e hematócrito (46 ± 2%) ao longo do estudo. Comparados ao SHAM, os animais CLP apresentaram aumento no número de leucócitos em rolamento (2x), aderidos (7x) e migrados (7x) na microcirculação mesentérica, aumentos da glicemia (136 ± 8 mg/dL), lactato (3,58 ± 0,94 mmol/L), leucocitose (23.570 ± 4.991 células/mm³) e alterações clínicas (escore 11±1), caracterizadas por comprometimento do estado de alerta e mobilidade, e presença de piloereção, diarréia, olhos encrustados, nariz e cauda sujos. REL normalizou o número de leucócitos em rolamento, aderidos e migrados no mesentério, a glicemia, o lactato e o número de leucócitos circulantes. REL também melhorou o escore clínico (7 ± 1). CONCLUSÃO: A CLP induziu inflamação local e sistêmica. A REL resolveu, por completo, o processo inflamatório

    Effect of electronic doping and traps on carrier dynamics in tin halide perovskites

    Get PDF
    Tin halide perovskites have recently emerged as promising materials for low band gap solar cells. Much effort has been invested on controlling the limiting factors responsible for poor device efficiencies, namely self-p-doping and tin oxidation. Both phenomena are related to the presence of defects; however, full understanding of their implications in the optoelectronic properties of the material is still missing. We provide a comprehensive picture of the competing radiative and non-radiative recombination processes in tin-based perovskite thin films to establish the interplay between doping and trapping by combining photoluminescence measurements with trapped-carrier dynamic simulations and first-principles calculations. We show that pristine Sn perovskites, i.e. sample processed with commercially available SnI2 used as received, exhibit extremely high radiative efficiency due to electronic doping which boosts the radiative band-to-band recombination. Contrarily, thin films where Sn4+ species are intentionally introduced show drastically reduced radiative lifetime and efficiency due to a dominance of Auger recombination at all excitation densities when the material is highly doped. The introduction of SnF2 reduces the doping and passivates Sn4+ trap states but conversely introduces additional non-radiative decay channels in the bulk that fundamentally limit the radiative efficiency. Overall, we provide a qualitative model that takes into account different types of traps present in tin-perovskite thin films and show how doping and defects can affect the optoelectronic properties
    corecore