87 research outputs found

    Exploiting the Hierarchical Morphology of Single-Walled and Multi-Walled Carbon Nanotube Films for Highly Hydrophobic Coatings

    Get PDF
    Self-assembled hierarchical solid surfaces are very interesting for wetting phenomena, as observed in a variety of natural and artificial surfaces. Here, we report single-walled (SWCNT) and multi-walled carbon nanotube (MWCNT) thin films realized by a simple, rapid, reproducible, and inexpensive filtration process from an aqueous dispersion, that was deposited at room temperature by a dry-transfer printing method on glass. Furthermore, the investigation of carbon nanotube films through scanning electron microscopy (SEM) reveals the multi-scale hierarchical morphology of the self-assembled carbon nanotube random networks. Moreover, contact angle measurements show that hierarchical SWCNT/MWCNT composite surfaces exhibit a higher hydrophobicity (contact angles of up to 137{\deg}) than bare SWCNT (110{\deg}) and MWCNT (97{\deg}) coatings, thereby confirming the enhancement produced by the surface hierarchical morphology.Comment: 7 pages, 5 figures, This article is part of the Thematic Series "Self-assembly of nanostructures and nanomaterials

    Super-Hydrophobic Multi-Walled Carbon Nanotube Coatings for Stainless Steel

    Full text link
    We have taken advantage of the native surface roughness and the iron content of AISI 316 stainless steel to direct grow multi-walled carbon nanotube (MWCNT) random networks by chemical vapor deposition (CVD) at low-temperature (<1000∘< 1000^{\circ}C), without the addition of any external catalysts or time-consuming pre-treatments. In this way, super-hydrophobic MWCNT films on stainless steel sheets were obtained, exhibiting high contact angle values (154∘154^{\circ}) and high adhesion force (high contact angle hysteresis). Furthermore, the investigation of MWCNT films at scanning electron microscopy (SEM) reveals a two-fold hierarchical morphology of the MWCNT random networks made of hydrophilic carbonaceous nanostructures on the tip of hydrophobic MWCNTs. Owing to the Salvinia effect, the hydrophobic and hydrophilic composite surface of the MWCNT films supplies a stationary super-hydrophobic coating for conductive stainless steel. This biomimetical inspired surface not only may prevent corrosion and fouling but also could provide low-friction and drag-reduction.Comment: 6 pages, 3 figure

    Morphology Analysis of Cu Film Fractures in Sandwiched Methylmethacrylate Plates

    Get PDF
    Thin films of Cu were evaporated on solid plates of polymethylmethacrylate (PMMA). A polymerization process was made to realize sandwiched structure to protect the Cu films. Fracturing of the metal film surface was observed with several morphologies showing two different fracture systems. Surface film morphology was analysed in terms of the distribution area of the islands and contour fractal dimension. The island areas showed a maximum corresponding to 42 nm of the Cu thickness, it was also the threshold to observe the second fracture system. The fractures pattern resulted to be scale invariant with fractal dimensions between 1.55 and 1.7. The minimum fractal dimension also occurred at the film thickness corresponding to the maximum island area. The reported effects can be understood on the basis of different thermal expansion coefficients of the two materials and their thermally induced adhesion.DOI: http://dx.doi.org/10.5755/j01.ms.21.2.651

    Carbon nanotube film/silicon heterojunction photodetector for new cutting-edge technological devices

    Get PDF
    Photodetector (PD) devices based on carbon nanotube/n-silicon heterojunction (NSH) have been realized, with a linear response in a large optical power range, proving competitive performances with respect to a recent nanostructure-based detector and those currently available on the market. The core of these devices is a thin semi-transparent and conductive single-walled carbon nanotubes film with a multitask role: junction element, light absorber and transmitter, photocarrier transporting layer, and charge collector. The PD exhibits rise times of some nanoseconds, detecting light from ultraviolet (240 nm) to infrared (1600 nm), and external quantum efficiency reaching 300% in the VIS spectra region

    Improvement in accuracy of diagnosis of carotid artery stenosis with duplex ultrasound scanning with combined use of linear array 7.5 MHz and convex array 3.5 MHz probes: validation versus 489 arteriographic procedures1 1Competition of interest: none.Published online Mar 6, 2003.

    Get PDF
    AbstractObjective: Validity of a method to improve the accuracy of carotid artery duplex scanning was tested in comparison with arteriography.Study Design: In 489 patients who had not previously undergone arteriography, 978 carotid arteries were examined with duplex ultrasound scanning. In method A, a linear array 7.5 MHz transducer with pulsed-wave 4.7 MHz Doppler scanning was used. For the diagnosis and grading of carotid stenosis, peak systolic and end-diastolic velocity of the Doppler waves were recorded. Method B consisted of complete ultrasound imaging and color-flow mapping with a convex array 3.5 MHz transducer with pulsed-wave 2.8 MHz Doppler scanning in all patients who had previously undergone method A. Further velocity measurements were performed at the sites of stenosis. The results of methods A and B were compared with data from neurologic assessment and arteriographic studies.Results: Method B showed significantly higher diagnostic agreement with arteriography than did method A (K 95% confidence interval [CI], 0.87–0.93 vs 0.79–0.85; P < .05), and the number of mistakes in grading stenosis was significantly lower (primarily because of decreased overestimation) in patients with internal carotid kinking (>60 degrees of angulation) (P < .05), distal stenosis (>20 mm from bifurcation) (P < .01), or wide acoustic shadowing (>1 cm) (P < .01) and in those without these conditions (P < .05). Compared with arteriography, diagnostic accuracy with the new method proved higher for carotid stenoses 50% or greater, 60% or greater, 70% or greater, and 80% or greater; no statistically significant difference was found for carotid stenosis 96% or greater or for carotid occlusion. Compared with data from neurologic assessment and arteriography, method B proved more accurate than method A in designating patients for carotid endarterectomy (P = .014).Conclusions: The new method significantly improved diagnostic reliability of duplex ultrasound scanning, especially in carotid arteries with kinking, distal stenosis, or wide acoustic shadowing (32.2% of all arteries studied). In clinical practice, we suggest additional use of a lower frequency transducer in cases in which these three conditions are found or suspected at first scanning

    Functional rewiring across spinal injuries via biomimetic nanofiber scaffolds

    Get PDF
    The regrowth of severed axons is fundamental to reestablish motor control after spinal-cord injury (SCI). Ongoing efforts to promote axonal regeneration after SCI have involved multiple strategies that have been only partially successful. Our study introduces an artificial carbon-nanotube based scaffold that, once implanted in SCI rats, improves motor function recovery. Confocal microscopy analysis plus fiber tracking by magnetic resonance imaging and neurotracer labeling of long-distance corticospinal axons suggest that recovery might be partly attributable to successful crossing of the lesion site by regenerating fibers. Since manipulating SCI microenvironment properties, such as mechanical and electrical ones, may promote biological responses, we propose this artificial scaffold as a prototype to exploit the physics governing spinal regenerative plasticity

    Minimally-invasive treatments for benign thyroid nodules: a Delphi-based consensus statement from the Italian minimally-invasive treatments of the thyroid (MITT) group

    Get PDF
    Benign thyroid nodules are a common clinical occurrence and usually do not require treatment unless symptomatic. During the last years, ultrasound-guided minimally invasive treatments (MIT) gained an increasing role in the management of nodules causing local symptoms. In February 2018, the Italian MIT Thyroid Group was founded to create a permanent cooperation between Italian and international physicians dedicated to clinical research and assistance on MIT for thyroid nodules. The group drafted this list of statements based on literature review and consensus opinion of interdisciplinary experts to facilitate the diffusion and the appropriate use of MIT of thyroid nodules in clinical practice. (#1) Predominantly cystic/cystic symptomatic nodules should first undergo US-guided aspiration; ethanol injection should be performed if relapsing (level of evidence [LoE]: ethanol is superior to simple aspiration = 2); (#2) In symptomatic cystic nodules, thermal ablation is an option when symptoms persist after ethanol ablation (LoE = 4); (#3) Double cytological benignity confirmation is needed before thermal ablation (LoE = 2); (#4) Single cytological sample is adequate in ultrasound low risk (EU-TIRADS 643) and in autonomously functioning nodules (LoE = 2); (#5) Thermal ablation may be proposed as first-line treatment for solid, symptomatic, nonfunctioning, benign nodules (LoE = 2); (#6) Thermal ablation may be used for dominant lesions in nonfunctioning multinodular goiter in patients refusing/not eligible for surgery (LoE = 5); (#7) Clinical and ultrasound follow-up is appropriate after thermal ablation (LoE = 2); (#8) Nodule re-treatment can be considered when symptoms relapse or partially resolve (LoE = 2); (#9) In case of nodule regrowth, a new cytological assessment is suggested before second ablation (LoE = 5); (#10) Thermal ablation is an option for autonomously functioning nodules in patients refusing/not eligible for radioiodine or surgery (LoE = 2); (#11) Small autonomously functioning nodules can be treated with thermal ablation when thyroid tissue sparing is a priority and 6580% nodule volume ablation is expected (LoE = 3)
    • …
    corecore