1,994 research outputs found

    Vision à long terme - Mer du Nord 2050

    Get PDF

    Beleidsverklaring 2017 Noordzee

    Get PDF

    Charging damage in floating metal-insulator-metal capacitors

    Get PDF
    In this paper, charging induced damage (CID) to metal-insulator-metal capacitors (MIMC) is reported. The damage is caused by the build up of a voltage potential difference between the two plates of the capacitor. A simple logarithmic relation is discovered between the damage by this voltage potential and the ratio of the area of the exposed antennas connected to the plates of the MIMC. This function allows anticipation of damage in MIMC devices with long interconnects. The source of the damage is still the subject of further investigatio

    Plasma damage in floating metal-insulator-metal capacitors

    Get PDF
    In this paper, charging induced damage (CID) to metal-insulator-metal capacitors (MIMCs), is reported. CID does not necessarily lead to direct yield loss, but may also induce latent damage leading to reliability losses. The damage is caused by the build up of a voltage potential difference between the two plates of the capacitor. A simple logarithmic relation is discovered between the damage by this voltage potential and the ratio of the area of the exposed antennas connected to the plates of the MIMC. This function allows anticipation of damage in MIMCs with long interconnect

    Job stress in relation to heart rate variability

    Get PDF

    Bottom slamming on heaving point absorber wave energy devices

    Get PDF
    Oscillating point absorber buoys may rise out of the water and be subjected to bottom slamming upon re-entering the water. Numerical simulations are performed to estimate the power absorption, the impact velocities and the corresponding slamming forces for various slamming constraints. Three buoy shapes are considered: a hemisphere and two conical shapes with deadrise angles of 30 and 45, with a waterline diameter of 5 m. The simulations indicate that the risk of rising out of the water is largely dependent on the buoy draft and sea state. Although associated with power losses, emergence occurrence probabilities can be significantly reduced by adapting the control parameters. The magnitude of the slamming load is severely influenced by the buoy shape. The ratio between the peak impact load on the hemisphere and that on the 45 cone is approximately 2, whereas the power absorption is only 4-8% higher for the 45° cone. This work illustrates the need to include slamming considerations aside from power absorption criteria in the buoy shape design process and the control strategy

    Classifying hyperspectral airborne imagery for vegetation survey along coastlines

    Get PDF
    This paper studies the potential of airborne hyperspectral imagery for classifying vegetation along the Belgian coastlines. Here, the aim is to build vegetation maps using automatic classification. Besides a general linear multiclass classifier (Linear Discriminant Analysis), several strategies for combining binary classifiers are proposed: one based on a hierarchical decision tree, one based on the Hamming distance between the codewords obtained by binary classifiers and one based on the coupling of posterior probabilities. In addition, a new procedure is proposed for spatial classification smoothing. This procedure takes into account spatial information by letting the decision for classification of a pixel depend on the classification probabilities of neighboring pixels. This is shown to render smoother classification images

    Determination of lidocaine and its two N-desethylated metabolites in dog and horse plasma by high-performance liquid chromatography combined with electrospray ionization tandem mass spectrometry

    Full text link
    peer reviewedA sensitive method for the quantification of lidocaine and its metabolites, monoethylglycinexylidide (MEGX) and glycinexylidide (GX), in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry is described. The sample preparation includes a liquid-liquid extraction with methyl tert-butylmethyl ether after addition of 2 M sodium hydroxide. Ethyl methylglycinexylidide (EMGX) is used as an internal standard. For chromatographic separation, an ODS Hypersil column was used. Isocratic elution was achieved with 0.0 1 M ammonium acetate and acetonitrile as mobile phases. Good linearity was observed in the range of 2.5-1000 ng ml(-1) for lidocame in both dog and horse plasma. For MEGX, linear calibration curves were obtained in the range of 5-1000 ng ml(-1) and 20-1000 ng ml(-1) for dog and horse plasma, respectively. In dog and horse plasma good linearity was observed in the range of 200-1500 ng ml(-1) for GX. The limit of quantification (LOQ) in dog plasma for lidocaine, MEGX and GX was set at 2.5 ng ml(-1), 20 ng ml(-1) and 200 ng ml(-1), respectively. For horse plasma a limit of quantification of 2.5 ng ml(-1), 5 ng ml(-1) and 200 ng ml(-1) was achieved for lidocaine, MEGX and GX, respectively. In dog plasma, the limit of detection (LOD) was found to be 0.8 ng ml(-1), 2.3 ng ml(-1) and 55 ng ml(-1) for lidocaine, MEGX and GX, respectively. In horse plasma the LOD's found for lidocame, MEGX and GX, were 1.1 ng ml(-1), 0.5 ng ml(-1) and 13 ng ml(-1), respectively. The method was shown to be of use in pharmacokinetic studies after application of a transdermal patch in dogs and after an intravenous infusion in horses. (c) 2007 Elsevier B.V. All rights reserved
    corecore