41 research outputs found

    Evaluation of in-channel amperometric detection using a dual-channel microchip electrophoresis device and a two-electrode potentiostat for reverse polarity separations: Microfluidics and Miniaturization

    Get PDF
    In-channel amperometric detection combined with dual-channel microchip electrophoresis is evaluated using a two-electrode isolated potentiostat for reverse polarity separations. The device consists of two separate channels with the working and reference electrodes placed at identical positions relative to the end of the channel, enabling noise subtraction. In previous reports of this configuration, normal polarity and a three-electrode detection system were used. In the two-electrode detection system described here, the electrode in the reference channel acts as both the counter and reference. The effect of electrode placement in the channels on noise and detector response was investigated using nitrite, tyrosine, and hydrogen peroxide as model compounds. The effects of electrode material and size and type of reference electrode on noise and the potential shift of hydrodynamic voltammograms for the model compounds were determined. In addition, the performance of two- and three-electrode configurations using Pt and Ag/AgCl reference electrodes was compared. Although the signal was attenuated with the Pt reference, the noise was also significantly reduced. It was found that lower LOD were obtained for all three compounds with the dual-channel configuration compared to single-channel, in-channel detection. The dual-channel method was then used for the detection of nitrite in a dermal microdialysis sample obtained from a sheep following nitroglycerin administration

    Sensor Surface Design with NanoMaterials: A New Platform in the Diagnosis of COVID-19

    Get PDF
    Mass testing for COVID-19 is essential to defining patient management strategies, choosing the best clinical management, and dimensioning strategies for controlling viral dissemination and immunization strategies. Thus, it is of utmost importance to search for devices that allow a quick and reliable diagnosis of low cost that can be transposed from the bench to the bedside, such as biosensors. These devices can help choose the correct clinical management to minimize factors that lead to infected patients developing more severe diseases. The use of nanomaterials to modify biosensors’ surfaces to increase these devices’ sensitivity and their biofunctionality enables high-quality nanotechnological platforms. In addition to the diagnostic benefits, nanotechnological platforms that facilitate the monitoring of anti-SARS-CoV-2 antibodies may be the key to determining loss of protective immune response after an episode of COVID-19, which leads to a possible chance of reinfection, as well as how they can be used to assess and monitor the success of immunization strategies, which are beginning to be administered on a large scale and that the extent and duration of their protection will need to be determined. Therefore, in this chapter, we will cover nanomaterials’ use and their functionalities in the surface design of sensors, thus generating nanotechnological platforms in the various facets of the diagnosis of COVID-19

    Rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART): Study protocol for a randomized controlled trial

    Get PDF
    Background: Acute respiratory distress syndrome (ARDS) is associated with high in-hospital mortality. Alveolar recruitment followed by ventilation at optimal titrated PEEP may reduce ventilator-induced lung injury and improve oxygenation in patients with ARDS, but the effects on mortality and other clinical outcomes remain unknown. This article reports the rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART). Methods/Design: ART is a pragmatic, multicenter, randomized (concealed), controlled trial, which aims to determine if maximum stepwise alveolar recruitment associated with PEEP titration is able to increase 28-day survival in patients with ARDS compared to conventional treatment (ARDSNet strategy). We will enroll adult patients with ARDS of less than 72 h duration. The intervention group will receive an alveolar recruitment maneuver, with stepwise increases of PEEP achieving 45 cmH(2)O and peak pressure of 60 cmH2O, followed by ventilation with optimal PEEP titrated according to the static compliance of the respiratory system. In the control group, mechanical ventilation will follow a conventional protocol (ARDSNet). In both groups, we will use controlled volume mode with low tidal volumes (4 to 6 mL/kg of predicted body weight) and targeting plateau pressure <= 30 cmH2O. The primary outcome is 28-day survival, and the secondary outcomes are: length of ICU stay; length of hospital stay; pneumothorax requiring chest tube during first 7 days; barotrauma during first 7 days; mechanical ventilation-free days from days 1 to 28; ICU, in-hospital, and 6-month survival. ART is an event-guided trial planned to last until 520 events (deaths within 28 days) are observed. These events allow detection of a hazard ratio of 0.75, with 90% power and two-tailed type I error of 5%. All analysis will follow the intention-to-treat principle. Discussion: If the ART strategy with maximum recruitment and PEEP titration improves 28-day survival, this will represent a notable advance to the care of ARDS patients. Conversely, if the ART strategy is similar or inferior to the current evidence-based strategy (ARDSNet), this should also change current practice as many institutions routinely employ recruitment maneuvers and set PEEP levels according to some titration method.Hospital do Coracao (HCor) as part of the Program 'Hospitais de Excelencia a Servico do SUS (PROADI-SUS)'Brazilian Ministry of Healt

    Some Applications of Electrochemistry in Biomedical Chemistry. Emphasis on the Correlation of Electrochemical and Bioactive Properties

    No full text
    This review summarises some of the more relevant achievements in the correlation between electrochemical processes and parameters and bioactive properties, mainly related to cancer and tropical diseases. Despite the broad range of possibilities and the complexity of cell/tissue/extracell chemistry, it is possible to rationalise the role of electrochemistry in few basic theoretical frameworks, mainly, the one based on electron transfer-oxidative stress and in situ generation of toxic species, other than the reactive oxygen species; interaction with endobiotics, with emphasis on bioreductive alkylation and replacement of endobiotics with function in biological redox reactions. The use of electrochemical methods to obtain relevant informations about drugs' mechanism of action and analysis of cellular events is also presented. Electrochemical methods and/or parameters play essential but not absolute roles

    Synthesis and Charaterization of Silica-Based Aldehyde Chitosan Hybrid Material for Biodiesel Purification

    No full text
    This study concerns the development and charaterization of Silica-based aldehyde Chitosan hybrid material as an adsorbent for biodiesel purification. This biocomposite was prepared by sol-gel route and oxidation with periodate, and then characterized. FTIR experiments showed that the hybrid formed presents absorption bands similar to those of Chitosan-Silica, with the exception of the vibrations at 1480 cm−1 and 1570 cm−1 attributed to the symmetrical angular deformation in the N-H plane, and possess large N2 Brunauer–Emmett–Teller (BET) surface areas. Thermogravimetric analysis (TG) and scanning electron microscopy (SEM) was also carried out. Adsorption studies of bioadsorbents involving the analysis of free glycerol, soap, acidity, diglycerides, triglycerides, and fluorescence spectroscopy showed that silica-based aldehyde chitosan has a good affinity for glycerol and a good purification process
    corecore