1,796 research outputs found

    Optimizing computational methods of modeling vertebroplasty in experimentally augmented human lumbar vertebrae

    No full text
    Vertebroplasty has been widely used for the treatment of osteoporotic compression fractures but the efficacy of the technique has been questioned by the outcomes of randomized clinical trials. Finite‐element (FE) models allow an investigation into the structural and geometric variation that affect the response to augmentation. However, current specimen‐specific FE models are limited due to their poor reproduction of cement augmentation behavior. The aims of this study were to develop new methods of modeling the vertebral body in both a nonaugmented and augmented state. Experimental tests were conducted using human lumbar spine vertebral specimens. These tests included micro‐computed tomography imaging, mechanical testing, augmentation with cement, reimaging, and retesting. Specimen‐specific FE models of the vertebrae were made comparing different approaches to capturing the bone material properties and to modeling the cement augmentation region. These methods significantly improved the modeling accuracy of nonaugmented vertebrae. Methods that used the registration of multiple images (pre‐ and post‐augmentation) of a vertebra achieved good agreement between augmented models and their experimental counterparts in terms of predictions of stiffness. Such models allow for further investigation into how vertebral variation influences the mechanical outcomes of vertebroplasty

    Primary Angle Closure: Epidemiology and Ocular Biometric Associations in European Populations

    Get PDF
    Aims: To describe the epidemiology, biometric characteristics and risk factors for primary angle closure disease (PAC & PACG) in European people. Methods: 1.Systematic reviews of PACG prevalence and acute angle closure (AAC) incidence studies; with prevalence modelling, and incidence trend analysis. 2.Analyses of EAGLE study data to investigate for differences in presenting characteristics by diagnosis , ethnicity and PACG severity. 3.Quantification of risk factors associated with PAC/ PACG by case-control analysis using EAGLE, EPIC-Norfolk and Liwan Eye Study data. 4.Genotype-phenotype correlation study of SNPs recently associated with PACG, and ocular biometry in participants of the EPIC-Norfolk Eye Study. 5.Investigation into the epidemiology and characteristics of EPIC-Norfolk participants with nanophthalmos: the “angle closure phenotype.” Results: 1.PAGC prevalence was estimated as 0.4% in those ≥40 years old. AAC incidence appears to be reducing, equivalent to halving over the past decade. 2.EAGLE participants with PACG were older, had longer axial length (AL) and thinner CCT than those with PAC. Chinese ethnicity was associated with a shallower anterior chamber depth (ACD), less hyperopia and thinner CCT. PACG severity was associated with IOP, ACD and Chinese ethnicity. 3.The odds of PAC/ PACG were 33 times and 15 times higher per 1mm shallower ACD for non-Chinese andChinese people respectively. For each 1mm less AL, the odds of PAC/ PACG were 2.7and 1.8 times higher for non-Chinese and Chinese respectively . 4.PACG risk locus, rs1015213, may exert at least part of its effect through an association with ACD in European populations. 5.There is no standardized definition for nanophthalmos. Small eyes were more common than expected and associated with visual impairment. Conclusions: PACG appears to have been historically under-recognised in populations of European descent. This series of work provides a basis for future angle closure disease risk models

    The Royal College of Ophthalmologists' National Ophthalmology Database study of cataract surgery: report 1, visual outcomes and complications.

    Get PDF
    Aim To describe the outcomes of cataract surgery in the United Kingdom. Methods Anonymised data on 180 114 eyes from 127 685 patients undergoing cataract surgery between August 2006 and November 2010 were collected prospectively from 28 sites. Outcome measures included intraoperative and postoperative complication rates, and preoperative and postoperative visual acuities. Results Median age at first eye surgery was 77.1 years, 36.9% cases had ocular co-pathology and 41.0% patients underwent cataract surgery on both eyes. Preoperative visual acuity was 0.30 logMAR or better in 32.0% first eyes and 47.7% second eyes. Postoperative best-measured visual acuity was 0.00 and 0.30 logMAR or better in 50.8 and 94.6% eyes without ocular co-pathology, and 32.5 and 79.9% in eyes with co-pathology. For eyes without co-pathology, postoperative uncorrected distance visual acuity was 0.00 and 0.30 logMAR or better in 27.3 and 80.9% eyes. Posterior capsule rupture or vitreous loss or both occurred in 1.95% cases, and was associated with a 42 times higher risk of retinal detachment surgery within 3 months and an eight times higher risk of endophthalmitis. Conclusion These results provide updated data for the benchmarking of cataract surgery. Visual outcomes, and the rate of posterior capsule rupture or vitreous loss or both appear stable over the past decade

    A method for the isolation of schistosome eggs and miracidia free of contaminating host tissues

    Full text link
    A novel method for the isolation of schistosome eggs and miracidia from livers of mice infected with Schistosoma japonicum or S. mansoni is described. The method employed collagenase B to degrade the interstitial matrix of mouse liver tissue, after which the schistosome eggs were separated from the liver cells by 2 single-step density centrifugations through Percoll. Using this procedure sufficient quantities of miracidia were obtained to generate a cDNA library. Southern blot analysis demonstrated that miracidia isolated by this method were free from contaminating host DNA

    Synthesis of new chiral organosulfur donors with hydrogen bonding functionality and their first charge transfer salts

    Get PDF
    The syntheses of a range of enantiopure organosulfur donors with hydrogen bonding groups are described including TTF related materials with two, four, six and eight hydroxyl groups and multiple stereogenic centres and a pair of chiral N-substituted BEDT-TTF acetamides. Three charge transfer salts of enantiopure poly-hydroxy-substituted donors are reported, including a 4:1 salt with the meso stereoisomer of the dinuclear [Fe2(oxalate)5 ]4- anion in which both cation and anion have chiral components linked together by hydrogen bonding, and a semiconducting salt with triiodide

    Femtosecond Laser–Assisted Deep Anterior Lamellar Keratoplasty for Keratoconus: Multi-surgeon Results

    Get PDF
    PURPOSE: To compare the clinical outcomes in femtosecond laser–assisted deep anterior lamellar keratoplasty (F-DALK) to manual non-laser deep anterior lamellar keratoplasty (M-DALK) for keratoconus in a multi-surgeon public healthcare setting. DESIGN: Single-center, comparative, retrospective interventional case series. METHODS: Population: Consecutive cases of keratoconus treated with big-bubble F-DALK from August 1, 2015, to September 1, 2018 and big-bubble M-DALK from September 1, 2012, to September 30, 2016. Setting: Moorfields Eye Hospital, London. Observations: Data on preoperative status, operative details, intraoperative and postoperative complications, secondary interventions, and visual outcomes were archived on a customized spreadsheet for analysis. Main Outcome Measures: Rate of intraoperative perforation and conversion to penetrating keratoplasty (PK) and the percentage of patients, post removal of sutures (ROS), with corrected distance visual acuity (CDVA) ≥20/40. RESULTS: We analyzed 58 eyes of 55 patients who underwent F-DALK and 326 eyes of 309 patients who underwent M-DALK. Intraoperative perforation of Descemet membrane occurred in 15 of 58 (25.9%) F-DALK cases compared to 148 of 326 (45.4%) M-DALK cases (P = .006). Intraoperative conversion to PK was carried out in 2 of 58 (3.4%) F-DALK cases compared to 80 of 326 (24.5%) M-DALK cases (P = .001). Post ROS, 86.5% of F-DALK eyes had a CDVA of ≥20/40 (15 ± 7.3 months after surgery) compared to 83.7% of M-DALK eyes (24.9 ± 10.6 months) (P = .825). CONCLUSION: Laser automation of some steps in DALK for keratoconus may reduce the rate of intraoperative Descemet perforation and the conversion to PK in a multi-surgeon setting

    The Association of Ambient Air Pollution With Cataract Surgery in UK Biobank Participants: Prospective Cohort Study

    Get PDF
    Purpose: Air pollution is associated with chronic diseases of later life. Cataract is the most common cause of blindess globally. It is biologically plausible that cataract risk is increased by pollution exposure. Therefore, the relationship between air pollution and incident cataract surgery was examined. Methods: This was a prospective, observational study involving 433,727 UK Biobank participants. Ambient air pollution measures included particulates, nitrogen dioxide (NO2) and nitrogen oxides (NOx). Outdoor air pollution was estimated based on land use regression models. Participants undergoing cataract surgery in either eye were ascertained via data linkage to the National Health Service procedure statistics. Those undergoing cataract surgery within 1 year of baseline assessment and those reporting cataract at baseline were excluded. Cox proportional hazards models were used to examine the associations between air pollutants and incident cataract surgery, adjusting for sociodemographic and lifestyle factors. Results: There were 16,307 incident cases of cataract surgery. Higher exposure to PM2.5 was associated with a 5% increased risk of incident cataract surgery (per interquartile range [IQR] increase). Compared to the lowest quartile, participants with exposures to PM2.5, NO2, and NOx in the highest quartile were 14%, 11%, and 9% more likely to undergo cataract surgery, respectively. A continuous exposure-response relationship was observed, with the likelihood of undergoing cataract surgery being progressively higher with greater levels of PM2.5, NO2, and NOx (P for trend P < 0.001). Conclusions: Although the results of our study showed a 5% increased risk of future cataract surgery following an exposure to PM2.5, NO2, and NOx, the effect estimates were relatively small. Further research is required to determine if the associations identified are causal

    Femtosecond laser-assisted cataract surgery compared with phacoemulsification: the FACT non-inferiority RCT

    Get PDF
    BACKGROUND: Cataract surgery is one of the most common operations. Femtosecond laser-assisted cataract surgery (FLACS) is a technique that automates a number of operative steps. OBJECTIVES: To compare FLACS with phacoemulsification cataract surgery (PCS). DESIGN: Multicentre, outcome-masked, randomised controlled non-inferiority trial. SETTING: Three collaborating NHS hospitals. PARTICIPANTS: A total of 785 patients with age-related cataract in one or both eyes were randomised between May 2015 and September 2017. INTERVENTION: FLACS (n = 392 participants) or PCS (n = 393 participants). MAIN OUTCOME MEASURES: The primary outcome was uncorrected distance visual acuity in the study eye after 3 months, expressed as the logarithm of the minimum angle of resolution (logMAR): 0.00 logMAR (or 6/6 if expressed in Snellen) is normal (good visual acuity). Secondary outcomes included corrected distance visual acuity, refractive outcomes (within 0.5 dioptre and 1.0 dioptre of target), safety and patient-reported outcome measures at 3 and 12 months, and resource use. All trial follow-ups were performed by optometrists who were masked to the trial intervention. RESULTS: A total of 353 (90%) participants allocated to the FLACS arm and 317 (81%) participants allocated to the PCS arm attended follow-up at 3 months. The mean uncorrected distance visual acuity was similar in both treatment arms [0.13 logMAR, standard deviation 0.23 logMAR, for FLACS, vs. 0.14 logMAR, standard deviation 0.27 logMAR, for PCS, with a difference of -0.01 logMAR (95% confidence interval -0.05 to 0.03 logMAR; p = 0.63)]. The mean corrected distance visual acuity values were again similar in both treatment arms (-0.01 logMAR, standard deviation 0.19 logMAR FLACS vs. 0.01 logMAR, standard deviation 0.21 logMAR PCS; p = 0.34). There were two posterior capsule tears in the PCS arm. There were no significant differences between the treatment arms for any secondary outcome at 3 months. At 12 months, the mean uncorrected distance visual acuity was 0.14 logMAR (standard deviation 0.22 logMAR) for FLACS and 0.17 logMAR (standard deviation 0.25 logMAR) for PCS, with a difference between the treatment arms of -0.03 logMAR (95% confidence interval -0.06 to 0.01 logMAR; p = 0.17). The mean corrected distance visual acuity was 0.003 logMAR (standard deviation 0.18 logMAR) for FLACS and 0.03 logMAR (standard deviation 0.23 logMAR) for PCS, with a difference of -0.03 logMAR (95% confidence interval -0.06 to 0.01 logMAR; p = 0.11). There were no significant differences between the arms for any other outcomes, with the exception of the mean binocular corrected distance visual acuity with a difference of -0.02 logMAR (95% confidence interval -0.05 to 0.00 logMAR) (p = 0.036), which favoured FLACS. There were no significant differences between the arms for any health, social care or societal costs. For the economic evaluation, the mean cost difference was £167.62 per patient higher for FLACS (95% of iterations between -£14.12 and £341.67) than for PCS. The mean QALY difference (FLACS minus PCS) was 0.001 (95% of iterations between -0.011 and 0.015), which equates to an incremental cost-effectiveness ratio (cost difference divided by QALY difference) of £167,620. LIMITATIONS: Although the measurement of outcomes was carried out by optometrists who were masked to the treatment arm, the participants were not masked. CONCLUSIONS: The evidence suggests that FLACS is not inferior to PCS in terms of vision after 3 months' follow-up, and there were no significant differences in patient-reported health and safety outcomes after 12 months' follow-up. In addition, the statistically significant difference in binocular corrected distance visual acuity was not clinically significant. FLACS is not cost-effective. FUTURE WORK: To explore the possible differences in vision in patients without ocular co-pathology. TRIAL REGISTRATION: Current Controlled Trials ISRCTN77602616. FUNDING: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 25, No. 6. See the NIHR Journals Library website for further project information. Moorfields Eye Charity (grant references GR000233 and GR000449 for the endothelial cell counter and femtosecond laser used)

    Femtosecond Laser-Assisted Cataract Surgery Versus Phacoemulsification Cataract Surgery (FACT): A Randomized Noninferiority Trial

    Get PDF
    PURPOSE: To report the 3-month results of a randomized trial (Femtosecond Laser-Assisted Cataract Trial [FACT]) comparing femtosecond laser-assisted cataract surgery (FLACS) with standard phacoemulsification cataract surgery (PCS). DESIGN: Multicenter, randomized controlled trial funded by the UK National Institute of Health Research (HTA 13/04/46/). PARTICIPANTS: Seven hundred eighty-five patients with age-related cataract. METHODS: This trial took place in 3 hospitals in the UK National Health Service (NHS). Randomization (1:1) was stratified by site, surgeon, and 1 or both eyes eligible using a secure web-based system. Postoperative assessments were masked to the allocated intervention. The primary outcome was unaided distance visual acuity (UDVA) in the study eye at 3 months. Secondary outcomes included corrected distance visual acuity, complications, and patient-reported outcomes measures. The noninferiority margin was 0.1 logarithm of the minimum angle of resolution (logMAR). ISRCTN.com registry, number ISRCTN77602616. MAIN OUTCOME MEASURES: We enrolled 785 participants between May 2015 and September 2017 and randomly assigned 392 to FLACS and 393 to PCS. At 3 months postoperatively, mean UDVA difference between treatment arms was -0.01 logMAR (-0.05 to 0.03), and mean corrected distance visual acuity difference was -0.01 logMAR (95% confidence interval [CI], -0.05 to 0.02). Seventy-one percent of both FLACS and PCS cases were within ±0.5 diopters (D) of the refractive target, and 93% of FLACS and 92% of PCS cases were within ±1.0 D. There were 2 posterior capsule tears in the PCS arm and none in the FLACS arm. There were no significant differences between arms for any secondary outcome. CONCLUSIONS: Femtosecond laser-assisted cataract surgery is not inferior to conventional PCS surgery 3 months after surgery. Both methods are as good in terms of vision, patient-reported health, and safety outcomes at 3 months. Longer-term outcomes of the clinical effectiveness and cost-effectiveness are awaited
    corecore