1,625 research outputs found

    Footwear matters: influence of footwear and foot strike on load rates during running

    Get PDF
    This is the author accepted manuscript. The final version is available from the publisher via the DOI in this record.This is a non-final version of an article published in final form in Medicine and Science in Sports 22 and Exercise, 2016 Jul 6.INTRODUCTION: Running with a forefoot strike (FFS) pattern has been suggested to reduce the risk of overuse running injuries, due to a reduced vertical loadrate compared with rearfoot strike (RFS) running. However, resultant loadrate has been reported to be similar between foot strikes when running in traditional shoes, leading to questions regarding the value of running with a FFS. The influence of minimal footwear on the resultant loadrate has not been considered. This study aimed to compare component and resultant instantaneous loadrate (ILR) between runners with different foot strike patterns in their habitual footwear conditions. METHODS: 29 injury-free participants (22 males, 7 females) ran at 3.13m.s along a 30m runway, with their habitual foot strike and footwear condition. Ground reaction force data were collected. Peak ILR values were compared between three conditions; those who habitually run with a RFS in standard shoes, with a FFS in standard shoes, and with a FFS in minimal shoes. RESULTS: Peak resultant, vertical, lateral and medial ILR were lower (P < 0.001) when running in minimal shoes with a FFS than in standard shoes with either foot strike. When running with a FFS, peak posterior ILR were lower (P < 0.001) in minimal than standard shoes. CONCLUSIONS: When running in a standard shoe, peak resultant and component instantaneous loadrates were similar between footstrike patterns. However, loadrates were lower when running in minimal shoes with a FFS, compared with running in standard shoes with either foot strike. Therefore, it appears that footwear alters the loadrates during running, even with similar foot strike patterns

    Footwear matters: influence of footwear and foot strike on load rates during running

    Get PDF
    This is the author accepted manuscript. The final version is available from the publisher via the DOI in this record.This is a non-final version of an article published in final form in Medicine and Science in Sports 22 and Exercise, 2016 Jul 6.INTRODUCTION: Running with a forefoot strike (FFS) pattern has been suggested to reduce the risk of overuse running injuries, due to a reduced vertical loadrate compared with rearfoot strike (RFS) running. However, resultant loadrate has been reported to be similar between foot strikes when running in traditional shoes, leading to questions regarding the value of running with a FFS. The influence of minimal footwear on the resultant loadrate has not been considered. This study aimed to compare component and resultant instantaneous loadrate (ILR) between runners with different foot strike patterns in their habitual footwear conditions. METHODS: 29 injury-free participants (22 males, 7 females) ran at 3.13m.s along a 30m runway, with their habitual foot strike and footwear condition. Ground reaction force data were collected. Peak ILR values were compared between three conditions; those who habitually run with a RFS in standard shoes, with a FFS in standard shoes, and with a FFS in minimal shoes. RESULTS: Peak resultant, vertical, lateral and medial ILR were lower (P < 0.001) when running in minimal shoes with a FFS than in standard shoes with either foot strike. When running with a FFS, peak posterior ILR were lower (P < 0.001) in minimal than standard shoes. CONCLUSIONS: When running in a standard shoe, peak resultant and component instantaneous loadrates were similar between footstrike patterns. However, loadrates were lower when running in minimal shoes with a FFS, compared with running in standard shoes with either foot strike. Therefore, it appears that footwear alters the loadrates during running, even with similar foot strike patterns

    The winemaker’s bug: From ancient wisdom to opening new vistas with frontier yeast science

    Get PDF
    The past three decades have seen a global wine glut. So far, well-intended but wasteful and expensive market-intervention has failed to drag the wine industry out of a chronic annual oversupply of roughly 15%. Can yeast research succeed where these approaches have failed by providing a means of improving wine quality, thereby making wine more appealing to consumers? To molecular biologists Saccharomyces cerevisiae is as intriguing as it is tractable. A simple unicellular eukaryote, it is an ideal model organism, enabling scientists to shed new light on some of the biggest scientific challenges such as the biology of cancer and aging. It is amenable to almost any modification that modern biology can throw at a cell, making it an ideal host for genetic manipulation, whether by the application of traditional or modern genetic techniques. To the winemaker, this yeast is integral to crafting wonderful, complex wines from simple, sugar-rich grape juice. Thus any improvements that we can make to wine, yeast fermentation performance or the sensory properties it imparts to wine will benefit winemakers and consumers. With this in mind, the application of frontier technologies, particularly the burgeoning fields of systems and synthetic biology, have much to offer in their pursuit of “novel” yeast strains to produce high quality wine. This paper discusses the nexus between yeast research and winemaking. It also addresses how winemakers and scientists face up to the challenges of consumer perceptions and opinions regarding the intervention of science and technology; the greater this intervention, the stronger the criticism that wine is no longer “natural.” How can wine researchers respond to the growing number of wine commentators and consumers who feel that scientific endeavors favor wine quantity over quality and “technical sophistication, fermentation reliability and product consistency” over “artisanal variation”? This paper seeks to present yeast research in a new light and a new context, and it raises important questions about the direction of yeast research, its contribution to science and the future of winemaking

    Sculpting oscillators with light within a nonlinear quantum fluid

    Full text link
    Seeing macroscopic quantum states directly remains an elusive goal. Particles with boson symmetry can condense into such quantum fluids producing rich physical phenomena as well as proven potential for interferometric devices [1-10]. However direct imaging of such quantum states is only fleetingly possible in high-vacuum ultracold atomic condensates, and not in superconductors. Recent condensation of solid state polariton quasiparticles, built from mixing semiconductor excitons with microcavity photons, offers monolithic devices capable of supporting room temperature quantum states [11-14] that exhibit superfluid behaviour [15,16]. Here we use microcavities on a semiconductor chip supporting two-dimensional polariton condensates to directly visualise the formation of a spontaneously oscillating quantum fluid. This system is created on the fly by injecting polaritons at two or more spatially-separated pump spots. Although oscillating at tuneable THz-scale frequencies, a simple optical microscope can be used to directly image their stable archetypal quantum oscillator wavefunctions in real space. The self-repulsion of polaritons provides a solid state quasiparticle that is so nonlinear as to modify its own potential. Interference in time and space reveals the condensate wavepackets arise from non-equilibrium solitons. Control of such polariton condensate wavepackets demonstrates great potential for integrated semiconductor-based condensate devices.Comment: accepted in Nature Physic

    Vernix caseosa peritonitis – no longer rare or innocent: a case series

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Vernix Caseosa peritonitis is a rare post caesarean section complication with only 19 case reports in the literature to date. Vernix caseosa spilt at the time of caesarean section is thought to incite an inflammatory reaction, causing symptoms resembling an acute abdomen.</p> <p>Case Presentation</p> <p>We discuss three Caucasian patients (aged 32 to 43 years) who presented in our health sector in Sydney with vernix caseosa peritonitis. Each had a protracted course with significant comorbidities requiring surgical and medical intervention. This contrasts with other reports suggesting that a rapid resolution can be expected.</p> <p>This cluster may be a consequence of the rising caesarean section rate, a heightened local awareness of the condition and possibly a result of leaving material in the paracolic gutters intraoperatively.</p> <p>Conclusion</p> <p>Our aim is to increase awareness among our obstetric and surgical colleagues of the characteristic clinical presentation and intra-operative findings of vernix caseosa peritonitis. We also point out that, in contrast to those presented here, not all patients require laparotomy.</p

    Axion-like-particle search with high-intensity lasers

    Full text link
    We study ALP-photon-conversion within strong inhomogeneous electromagnetic fields as provided by contemporary high-intensity laser systems. We observe that probe photons traversing the focal spot of a superposition of Gaussian beams of a single high-intensity laser at fundamental and frequency-doubled mode can experience a frequency shift due to their intermittent propagation as axion-like-particles. This process is strongly peaked for resonant masses on the order of the involved laser frequencies. Purely laser-based experiments in optical setups are sensitive to ALPs in the eV\mathrm{eV} mass range and can thus complement ALP searches at dipole magnets.Comment: 25 pages, 2 figure

    Seagrass can mitigate negative ocean acidification effects on calcifying algae

    Get PDF
    The ultimate effect that ocean acidification (OA) and warming will have on the physiology of calcifying algae is still largely uncertain. Responses depend on the complex interactions between seawater chemistry, global/local stressors and species-specific physiologies. There is a significant gap regarding the effect that metabolic interactions between coexisting species may have on local seawater chemistry and the concurrent effect of OA. Here, we manipulated CO2 and temperature to evaluate the physiological responses of two common photoautotrophs from shallow tropical marine coastal ecosystems in Brazil: the calcifying alga Halimeda cuneata, and the seagrass Halodule wrightii. We tested whether or not seagrass presence can influence the calcification rate of a widespread and abundant species of Halimeda under OA and warming. Our results demonstrate that under elevated CO2, the high photosynthetic rates of H. wrightii contribute to raise H. cuneata calcification more than two-fold and thus we suggest that H. cuneata populations coexisting with H. wrightii may have a higher resilience to OA conditions. This conclusion supports the more general hypothesis that, in coastal and shallow reef environments, the metabolic interactions between calcifying and non-calcifying organisms are instrumental in providing refuge against OA effects and increasing the resilience of the more OA-susceptible species.E.B. would like to thank the Coordenação de Aperfeiçoamento de Pessoas de Nível Superior (CAPES) for Masters funding. Funding for this project came from the Synergism grant (CNPq 407365/2013-3). We extend our thanks to the Brazil-based Projeto Coral Vivo and its sponsor PetroBras Ambiental for providing the Marine Mesocosm structure and experimental assistance.info:eu-repo/semantics/publishedVersio

    Comparative efficacy of topical tetraVisc versus lidocaine gel in cataract surgery

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To compare the clinical efficacy of lidocaine 2% with tetracaine 0.5% for cataract surgery.</p> <p>Methods</p> <p>In a randomized, multi-surgeon, controlled clinical trial,122 consecutive cataract cases eligible for topical anesthesia, were randomly assigned to receive lidocaine 2% gel (1 ml) or tetracaine solution 0.5% (TetraVisc, 0.5 ml) before clear corneal phacoemulsification. Main outcome measure was visual analog scale (0 to 10), which was used to measure intra-operative pain. Secondary outcome measures included patients' discomfort due to tissue manipulation and surgeon graded patients' cooperation. Duration of surgery and intra-operative complications were also recorded.</p> <p>Results</p> <p>The mean age in TetraVisc (TV) group was 70.4 years and in the lidocaine gel group (LG) it was 70.6 years (p = 0.89). Patient reported mean intra-operative pain scores by visual analog scale were 0.70 ± 0.31 in TV group and 1.8 ± 0.4 in LG group (<it>P </it>< 0.001). Mean patient cooperation was also marginally better in the TV group (8.3 ± 0.3) compared to LG group (8.4 ± 0.6) (P = 0.25). 96% of patients in TV group showed intra-operative corneal clarity compared to 91% in LG group. TV group had less (1 out of 61 patients, 1.6%) intra-operative complications than LG group (3 out of 61 patients, 4.8%). No anesthesia related complications were noted in either group</p> <p>Conclusion</p> <p>Topical TetraVisc solution was superior to lidocaine 2% gel for pain control in patients undergoing clear corneal phacoemulsification. Lidocaine 2% gel is similar to TetraVisc in patient comfort and surgeon satisfaction.</p> <p>Trial Registration</p> <p><b>Clinical trials number</b>: ISRCTN78374774</p
    • …
    corecore